426 related articles for article (PubMed ID: 32213685)
1. A prospective comparative study of ultrasonography, contrast-enhanced MRI and 18F-FDG PET/CT for preoperative detection of axillary lymph node metastasis in breast cancer patients.
Guney IB; Dalci K; Teke ZT; Kucuker KA
Ann Ital Chir; 2020; 91():458-464. PubMed ID: 32213685
[TBL] [Abstract][Full Text] [Related]
2. The Comparative Study of Ultrasonography, Contrast-Enhanced MRI, and (18)F-FDG PET/CT for Detecting Axillary Lymph Node Metastasis in T1 Breast Cancer.
Hwang SO; Lee SW; Kim HJ; Kim WW; Park HY; Jung JH
J Breast Cancer; 2013 Sep; 16(3):315-21. PubMed ID: 24155761
[TBL] [Abstract][Full Text] [Related]
3. Diagnostic performance of 18F-FDG PET/CT, ultrasonography and MRI. Detection of axillary lymph node metastasis in breast cancer patients.
An YS; Lee DH; Yoon JK; Lee SJ; Kim TH; Kang DK; Kim KS; Jung YS; Yim H
Nuklearmedizin; 2014; 53(3):89-94. PubMed ID: 24220324
[TBL] [Abstract][Full Text] [Related]
4. The Role of Axillary SUV
Karabacak U; Turkan H; Coskun G; Mollaoglu MC; Hasbek Z; Karadayi K
J Coll Physicians Surg Pak; 2023 Apr; 33(4):374-379. PubMed ID: 37190706
[TBL] [Abstract][Full Text] [Related]
5. Factors affecting the accuracy of
Kutluturk K; Simsek A; Comak A; Gonultas F; Unal B; Kekilli E
Niger J Clin Pract; 2019 Jan; 22(1):63-68. PubMed ID: 30666022
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients.
Riegger C; Koeninger A; Hartung V; Otterbach F; Kimmig R; Forsting M; Bockisch A; Antoch G; Heusner TA
Acta Radiol; 2012 Dec; 53(10):1092-8. PubMed ID: 23002144
[TBL] [Abstract][Full Text] [Related]
7. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer.
Ueda S; Tsuda H; Asakawa H; Omata J; Fukatsu K; Kondo N; Kondo T; Hama Y; Tamura K; Ishida J; Abe Y; Mochizuki H
BMC Cancer; 2008 Jun; 8():165. PubMed ID: 18541009
[TBL] [Abstract][Full Text] [Related]
8. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy.
Ergul N; Kadioglu H; Yildiz S; Yucel SB; Gucin Z; Erdogan EB; Aydin M; Muslumanoglu M
Acta Radiol; 2015 Aug; 56(8):917-23. PubMed ID: 25013091
[TBL] [Abstract][Full Text] [Related]
9. 2-fluoro-2-deoxy-D-glucose positron emission tomography versus conventional imaging for the diagnosis of breast cancer and lymph node metastases.
Shao M; Zi J; Wen G
J Cancer Res Ther; 2018 Sep; 14(Supplement):S661-S666. PubMed ID: 30249884
[TBL] [Abstract][Full Text] [Related]
10. Reliability of predicting low-burden (≤ 2) positive axillary lymph nodes indicating sentinel lymph node biopsy in primary operable breast cancer - a retrospective comparative study with PET/CT and breast MRI.
Sae-Lim C; Wu WP; Chang MC; Lai HW; Chen ST; Chou CT; Liao CY; Huang HI; Chen ST; Chen DR; Hung CL
World J Surg Oncol; 2024 Jan; 22(1):12. PubMed ID: 38183069
[TBL] [Abstract][Full Text] [Related]
11. Breast imaging. Preoperative breast cancer staging: comparison of USPIO-enhanced MR imaging and 18F-fluorodeoxyglucose (FDC) positron emission tomography (PET) imaging for axillary lymph node staging--initial findings.
Stadnik TW; Everaert H; Makkat S; Sacré R; Lamote J; Bourgain C
Eur Radiol; 2006 Oct; 16(10):2153-60. PubMed ID: 16670863
[TBL] [Abstract][Full Text] [Related]
12. Comparison of PET-CT and MRI for evaluation of axillary lymph nodes in early breast cancer patients.
Dulgeroglu O; Arikan AE; Capkinoglu E; Kara H; Uras C
Ann Ital Chir; 2022; 93():648-655. PubMed ID: 36617275
[TBL] [Abstract][Full Text] [Related]
13. Diagnostic value of full-dose FDG PET/CT for axillary lymph node staging in breast cancer patients.
Heusner TA; Kuemmel S; Hahn S; Koeninger A; Otterbach F; Hamami ME; Kimmig KR; Forsting M; Bockisch A; Antoch G; Stahl A
Eur J Nucl Med Mol Imaging; 2009 Oct; 36(10):1543-50. PubMed ID: 19415270
[TBL] [Abstract][Full Text] [Related]
14. Diagnostic accuracy of dual-time-point 18F-FDG PET/CT for the detection of axillary lymph node metastases in breast cancer patients.
Hahn S; Hecktor J; Grabellus F; Hartung V; Pöppel T; Kimmig R; Forsting M; Antoch G; Heusner TA
Acta Radiol; 2012 Jun; 53(5):518-23. PubMed ID: 22547387
[TBL] [Abstract][Full Text] [Related]
15. A comparative study of 18F-FDG PET/CT and ultrasonography in the diagnosis of breast cancer and axillary lymph node metastasis.
He X; Sun L; Huo Y; Shao M; Ma C
Q J Nucl Med Mol Imaging; 2017 Dec; 61(4):429-437. PubMed ID: 25823388
[TBL] [Abstract][Full Text] [Related]
16. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients: a feasibility study.
van Nijnatten TJA; Goorts B; Vöö S; de Boer M; Kooreman LFS; Heuts EM; Wildberger JE; Mottaghy FM; Lobbes MBI; Smidt ML
Eur J Nucl Med Mol Imaging; 2018 Feb; 45(2):179-186. PubMed ID: 28905091
[TBL] [Abstract][Full Text] [Related]
17. Selective Sentinel Node Plus Additional Non-Sentinel Node Biopsy Based on an FDG-PET/CT Scan in Early Breast Cancer Patients: Single Institutional Experience.
Kim J; Lee J; Chang E; Kim S; Suh K; Sul J; Song I; Kim Y; Lee C
World J Surg; 2009 May; 33(5):943-9. PubMed ID: 19259728
[TBL] [Abstract][Full Text] [Related]
18. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography combined with ultrasonography-guided fine needle aspiration cytology for identifying axillary lymph node status in patients with breast cancer.
Machida Y; Kubota K; Katayama T; Toriihara A; Shibuya H
Eur J Surg Oncol; 2013 Jan; 39(1):26-30. PubMed ID: 23122913
[TBL] [Abstract][Full Text] [Related]
19. A comparative study on the value of FDG-PET and sentinel node biopsy to identify occult axillary metastases.
Veronesi U; De Cicco C; Galimberti VE; Fernandez JR; Rotmensz N; Viale G; Spano G; Luini A; Intra M; Veronesi P; Berrettini A; Paganelli G
Ann Oncol; 2007 Mar; 18(3):473-8. PubMed ID: 17164229
[TBL] [Abstract][Full Text] [Related]
20. The role of ultrasonography and FDG-PET in axillary lymph node staging of breast cancer.
Ahn JH; Son EJ; Kim JA; Youk JH; Kim EK; Kwak JY; Ryu YH; Jeong J
Acta Radiol; 2010 Oct; 51(8):859-65. PubMed ID: 20670083
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]