These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
190 related articles for article (PubMed ID: 32217030)
1. Experimental Measurements of Ultrasound Attenuation in Human Chest Wall and Assessment of the Mechanical Index for Lung Ultrasound. Patterson B; Miller DL Ultrasound Med Biol; 2020 Jun; 46(6):1442-1454. PubMed ID: 32217030 [TBL] [Abstract][Full Text] [Related]
2. Lung Ultrasound Induction of Pulmonary Capillary Hemorrhage in Rats With Consideration of Exposimetric Relationships to Previous Similar Observations in Neonatal Swine. Miller DL; Dou C; Dong Z Ultrasound Med Biol; 2023 Jun; 49(6):1441-1448. PubMed ID: 36948896 [TBL] [Abstract][Full Text] [Related]
3. Attenuation coefficient and propagation speed estimates of rat and pig intercostal tissue as a function of temperature. Towa RT; Miller RJ; Frizzell LA; Zachary JF; O'Brien WD IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Oct; 49(10):1411-20. PubMed ID: 12403142 [TBL] [Abstract][Full Text] [Related]
4. In vivo ultrasonographic exposimetry: human tissue-specific attenuation coefficients in the gynecologic examination. Siddiqi TA; Miodovnik M; Meyer RA; O'Brien WD Am J Obstet Gynecol; 1999 Apr; 180(4):866-74. PubMed ID: 10203654 [TBL] [Abstract][Full Text] [Related]
5. Experimental acoustic characterization of an endoskeletal antibubble contrast agent: First results. Panfilova A; Chen P; van Sloun RJG; Wijkstra H; Postema M; Poortinga AT; Mischi M Med Phys; 2021 Nov; 48(11):6765-6780. PubMed ID: 34580883 [TBL] [Abstract][Full Text] [Related]
6. The acoustic properties, centered on 20 MHZ, of an IEC agar-based tissue-mimicking material and its temperature, frequency and age dependence. Brewin MP; Pike LC; Rowland DE; Birch MJ Ultrasound Med Biol; 2008 Aug; 34(8):1292-306. PubMed ID: 18343021 [TBL] [Abstract][Full Text] [Related]
7. Ultrasound assessment of the conversion of sound energy into heat in tissue phantoms enriched with magnetic micro- and nanoparticles. Gambin B; Kruglenko E; Tymkiewicz R; Litniewski J Med Phys; 2019 Oct; 46(10):4361-4370. PubMed ID: 31359439 [TBL] [Abstract][Full Text] [Related]
8. Accuracy of transthoracic ultrasound for the prediction of chest wall infiltration by lung cancer and of lung infiltration by chest wall tumours. Caroli G; Dell'Amore A; Cassanelli N; Dolci G; Pipitone E; Asadi N; Stella F; Bini A Heart Lung Circ; 2015 Oct; 24(10):1020-6. PubMed ID: 25911140 [TBL] [Abstract][Full Text] [Related]
9. Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz. Rajagopal S; Sadhoo N; Zeqiri B Ultrasound Med Biol; 2015 Jan; 41(1):317-33. PubMed ID: 25220268 [TBL] [Abstract][Full Text] [Related]
10. Exvivo ultrasound attenuation coefficient for human cervical and uterine tissue from 5 to 10 MHz. Kiss MZ; Varghese T; Kliewer MA Ultrasonics; 2011 May; 51(4):467-71. PubMed ID: 21163508 [TBL] [Abstract][Full Text] [Related]
11. Acoustic Properties of Breast Fat. Nasief HG; Rosado-Mendez IM; Zagzebski JA; Hall TJ J Ultrasound Med; 2015 Nov; 34(11):2007-16. PubMed ID: 26446820 [TBL] [Abstract][Full Text] [Related]
12. The effect of attenuation inside the acoustic traps on the configuration of vertical artifacts in lung ultrasound: an experimental study with simple models. Kameda T; Kamiyama N; Taniguchi N J Med Ultrason (2001); 2022 Oct; 49(4):545-553. PubMed ID: 35930175 [TBL] [Abstract][Full Text] [Related]
13. Ultrasonic propagation properties of excised human skin. Moran CM; Bush NL; Bamber JC Ultrasound Med Biol; 1995; 21(9):1177-90. PubMed ID: 8849832 [TBL] [Abstract][Full Text] [Related]
14. Pulse-Echo Technique to Compensate for Laminate Membrane Transmission Loss in Phantom-Based Ultrasonic Attenuation Coefficient Measurements. Nagabhushana K; Wang Q; Han A J Ultrasound Med; 2023 Jan; 42(1):45-58. PubMed ID: 35615811 [TBL] [Abstract][Full Text] [Related]
15. Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner. Garra BS; Shawker TH; Nassi M; Russell MA Ultrason Imaging; 1984 Oct; 6(4):396-407. PubMed ID: 6399170 [TBL] [Abstract][Full Text] [Related]
16. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter. Crescenti RA; Bamber JC; Partridge M; Bush NL; Webb S Phys Med Biol; 2007 Nov; 52(22):6747-59. PubMed ID: 17975295 [TBL] [Abstract][Full Text] [Related]
17. Dependence of thresholds for pulmonary capillary hemorrhage on diagnostic ultrasound frequency. Miller DL; Dou C; Raghavendran K Ultrasound Med Biol; 2015 Jun; 41(6):1640-50. PubMed ID: 25746909 [TBL] [Abstract][Full Text] [Related]