288 related articles for article (PubMed ID: 32219492)
1. Deep learning-based attenuation map generation for myocardial perfusion SPECT.
Shi L; Onofrey JA; Liu H; Liu YH; Liu C
Eur J Nucl Med Mol Imaging; 2020 Sep; 47(10):2383-2395. PubMed ID: 32219492
[TBL] [Abstract][Full Text] [Related]
2. Post-reconstruction attenuation correction for SPECT myocardium perfusion imaging facilitated by deep learning-based attenuation map generation.
Liu H; Wu J; Shi L; Liu Y; Miller E; Sinusas A; Liu YH; Liu C
J Nucl Cardiol; 2022 Dec; 29(6):2881-2892. PubMed ID: 34671940
[TBL] [Abstract][Full Text] [Related]
3. Deep-learning-based methods of attenuation correction for SPECT and PET.
Chen X; Liu C
J Nucl Cardiol; 2023 Oct; 30(5):1859-1878. PubMed ID: 35680755
[TBL] [Abstract][Full Text] [Related]
4. Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac SPECT.
Chen X; Zhou B; Xie H; Shi L; Liu H; Holler W; Lin M; Liu YH; Miller EJ; Sinusas AJ; Liu C
Eur J Nucl Med Mol Imaging; 2022 Jul; 49(9):3046-3060. PubMed ID: 35169887
[TBL] [Abstract][Full Text] [Related]
5. Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT.
Goetze S; Wahl RL
J Nucl Cardiol; 2007 Apr; 14(2):200-6. PubMed ID: 17386382
[TBL] [Abstract][Full Text] [Related]
6. Development of attenuation correction methods using deep learning in brain-perfusion single-photon emission computed tomography.
Murata T; Yokota H; Yamato R; Horikoshi T; Tsuneda M; Kurosawa R; Hashimoto T; Ota J; Sawada K; Iimori T; Masuda Y; Mori Y; Suyari H; Uno T
Med Phys; 2021 Aug; 48(8):4177-4190. PubMed ID: 34061380
[TBL] [Abstract][Full Text] [Related]
7. Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging.
Prieto Canalejo MA; Palau San Pedro A; Geronazzo R; Minsky DM; Juárez-Orozco LE; Namías M
Diagnostics (Basel); 2023 Jun; 13(13):. PubMed ID: 37443608
[TBL] [Abstract][Full Text] [Related]
8. DuDoSS: Deep-learning-based dual-domain sinogram synthesis from sparsely sampled projections of cardiac SPECT.
Chen X; Zhou B; Xie H; Miao T; Liu H; Holler W; Lin M; Miller EJ; Carson RE; Sinusas AJ; Liu C
Med Phys; 2023 Jan; 50(1):89-103. PubMed ID: 36048541
[TBL] [Abstract][Full Text] [Related]
9. Attenuation correction using deep learning for brain perfusion SPECT images.
Sakaguchi K; Kaida H; Yoshida S; Ishii K
Ann Nucl Med; 2021 May; 35(5):589-599. PubMed ID: 33751364
[TBL] [Abstract][Full Text] [Related]
10. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.
Goetze S; Brown TL; Lavely WC; Zhang Z; Bengel FM
J Nucl Med; 2007 Jul; 48(7):1090-5. PubMed ID: 17574985
[TBL] [Abstract][Full Text] [Related]
11. Deep learning approximation of attenuation maps for myocardial perfusion SPECT with an IQ[Formula: see text]SPECT collimator.
Huxohl T; Patel G; Zabel R; Burchert W
EJNMMI Phys; 2023 Aug; 10(1):49. PubMed ID: 37639082
[TBL] [Abstract][Full Text] [Related]
12. DuSFE: Dual-Channel Squeeze-Fusion-Excitation co-attention for cross-modality registration of cardiac SPECT and CT.
Chen X; Zhou B; Xie H; Guo X; Zhang J; Duncan JS; Miller EJ; Sinusas AJ; Onofrey JA; Liu C
Med Image Anal; 2023 Aug; 88():102840. PubMed ID: 37216735
[TBL] [Abstract][Full Text] [Related]
13. "Virtual" attenuation correction: improving stress myocardial perfusion SPECT imaging using deep learning.
Hagio T; Poitrasson-Rivière A; Moody JB; Renaud JM; Arida-Moody L; Shah RV; Ficaro EP; Murthy VL
Eur J Nucl Med Mol Imaging; 2022 Jul; 49(9):3140-3149. PubMed ID: 35312837
[TBL] [Abstract][Full Text] [Related]
14. CT-free attenuation correction for dedicated cardiac SPECT using a 3D dual squeeze-and-excitation residual dense network.
Chen X; Zhou B; Shi L; Liu H; Pang Y; Wang R; Miller EJ; Sinusas AJ; Liu C
J Nucl Cardiol; 2022 Oct; 29(5):2235-2250. PubMed ID: 34085168
[TBL] [Abstract][Full Text] [Related]
15. Deep-learning-based estimation of attenuation map improves attenuation correction performance over direct attenuation estimation for myocardial perfusion SPECT.
Du Y; Shang J; Sun J; Wang L; Liu YH; Xu H; Mok GSP
J Nucl Cardiol; 2023 Jun; 30(3):1022-1037. PubMed ID: 36097242
[TBL] [Abstract][Full Text] [Related]
16. Direct Attenuation Correction Using Deep Learning for Cardiac SPECT: A Feasibility Study.
Yang J; Shi L; Wang R; Miller EJ; Sinusas AJ; Liu C; Gullberg GT; Seo Y
J Nucl Med; 2021 Nov; 62(11):1645-1652. PubMed ID: 33637586
[TBL] [Abstract][Full Text] [Related]
17. Deep learning-based metal artefact reduction in PET/CT imaging.
Arabi H; Zaidi H
Eur Radiol; 2021 Aug; 31(8):6384-6396. PubMed ID: 33569626
[TBL] [Abstract][Full Text] [Related]
18. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT.
Kashiwagi T; Yutani K; Fukuchi M; Naruse H; Iwasaki T; Yokozuka K; Inoue S; Kondo S
Ann Nucl Med; 2002 Jun; 16(4):255-61. PubMed ID: 12126095
[TBL] [Abstract][Full Text] [Related]
19. Direct Image-Based Attenuation Correction using Conditional Generative Adversarial Network for SPECT Myocardial Perfusion Imaging.
Torkaman M; Yang J; Shi L; Wang R; Miller EJ; Sinusas AJ; Liu C; Gullberg GT; Seo Y
Proc SPIE Int Soc Opt Eng; 2021 Feb; 11600():. PubMed ID: 33727759
[TBL] [Abstract][Full Text] [Related]
20. Attenuation Correction for Dedicated Cardiac SPECT Imaging Without Using Transmission Data.
Tadesse GF; Geramifar P; Abbasi M; Tsegaw EM; Amin M; Salimi A; Mohammadi M; Teimourianfard B; Ay MR
Mol Imaging Radionucl Ther; 2023 Feb; 32(1):42-53. PubMed ID: 36818953
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]