134 related articles for article (PubMed ID: 32224535)
1. Development and biomechanical evaluation of a new biodegradable intramedullary implant for osteosynthesis of midshaft fractures of small hollow bones.
Pieske O; Bauer M; Schröder C; Michaelis I; Massen F; Wallmichrath J; Suero EM; Greiner A
Technol Health Care; 2020; 28(2):185-192. PubMed ID: 32224535
[TBL] [Abstract][Full Text] [Related]
2. Stimulation of fracture healing by local application of humoral factors integrated in biodegradable implants.
Illi OE; Feldmann CP
Eur J Pediatr Surg; 1998 Aug; 8(4):251-5. PubMed ID: 9783152
[TBL] [Abstract][Full Text] [Related]
3. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
[TBL] [Abstract][Full Text] [Related]
4. Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs.
Curtis BD; Fajolu O; Ruff ME; Litsky AS
Orthop Surg; 2015 Aug; 7(3):256-60. PubMed ID: 26311101
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison between solid and cannulated intramedullary devices for midshaft clavicle fixation.
Wang SH; Lin HJ; Shen HC; Pan RY; Yang JJ
BMC Musculoskelet Disord; 2019 Apr; 20(1):178. PubMed ID: 31027505
[TBL] [Abstract][Full Text] [Related]
6. Novel intramedullary-fixation technique for long bone fragility fractures using bioresorbable materials.
Nishizuka T; Kurahashi T; Hara T; Hirata H; Kasuga T
PLoS One; 2014; 9(8):e104603. PubMed ID: 25111138
[TBL] [Abstract][Full Text] [Related]
7. [A comparative study on two different absorbable intramedullary nails in treating metacarpal and phalanx fractures].
Huang C; Li J; Zhu J; Li P; Xie G; Gong Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2004 Sep; 18(5):360-3. PubMed ID: 15460043
[TBL] [Abstract][Full Text] [Related]
8. Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture.
Shanmugam R; Jian CYCCS; Haseeb A; Aik S
J Orthop Surg (Hong Kong); 2018; 26(3):2309499018802511. PubMed ID: 30270746
[TBL] [Abstract][Full Text] [Related]
9. [Surgical Treatment of Clavicle Midshaft Fractures - Prospective Randomized Trial].
Šimek J; Šmejkal K; Frank M; Hyšpler R; Dědek T; Páral J
Acta Chir Orthop Traumatol Cech; 2020; 87(2):101-107. PubMed ID: 32396510
[TBL] [Abstract][Full Text] [Related]
10. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.
Chan G; Korac Z; Miletic M; Vidovic D; Phadnis J; Bakota B
Injury; 2017 Nov; 48 Suppl 5():S21-S26. PubMed ID: 29122117
[TBL] [Abstract][Full Text] [Related]
11. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
[TBL] [Abstract][Full Text] [Related]
12. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
[TBL] [Abstract][Full Text] [Related]
13. An experimental study of the biomechanical stability of ultrasound-activated pinned (SonicWeld Rx+Resorb-X) and screwed fixed (Resorb-X) resorbable materials for osteosynthesis in the treatment of simulated craniosynostosis in sheep.
Pilling E; Meissner H; Jung R; Koch R; Loukota R; Mai R; Reitemeier B; Richter G; Stadlinger B; Stelnicki E; Eckelt U
Br J Oral Maxillofac Surg; 2007 Sep; 45(6):451-6. PubMed ID: 17275145
[TBL] [Abstract][Full Text] [Related]
14. Significance of biodegradable implants in case of midfacial fractures.
Hoffmann J; Troitzsch D; Gülicher D; Adam C; Reinert S
Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():496-9. PubMed ID: 12451904
[TBL] [Abstract][Full Text] [Related]
15. An in vitro biomechanical investigation of an MP35N intramedullary interlocking nail system for repair of third metacarpal fractures in adult horses.
Galuppo LD; Stover SM; Aldridge A; Hewes C; Taylor KT
Vet Surg; 2002; 31(3):211-25. PubMed ID: 11994848
[TBL] [Abstract][Full Text] [Related]
16. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
[TBL] [Abstract][Full Text] [Related]
17. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model.
Ochman S; Doht S; Paletta J; Langer M; Raschke MJ; Meffert RH
J Hand Surg Am; 2010 Apr; 35(4):597-603. PubMed ID: 20299161
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of plate osteosynthesis of distal fibula fractures with biodegradable devices.
Klos K; Sauer S; Hoffmeier K; Gras F; Fröber R; Hofmann GO; Mückley T
Foot Ankle Int; 2009 Mar; 30(3):243-51. PubMed ID: 19321102
[TBL] [Abstract][Full Text] [Related]
19. The Metacarpal Locked Intramedullary Nail: Comparative Biomechanical Evaluation of New Implant Design for Metacarpal Fractures.
Boonyasirikool C; Tanakeatsakul S; Niempoog S
J Med Assoc Thai; 2015 Apr; 98 Suppl 3():S91-5. PubMed ID: 26387394
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]