These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 32225084)

  • 1. Preparation of Isotopically Labelled Standards of Creatinine Via H/D Exchange and Their Application in Quantitative Analysis by LC-MS.
    Bąchor R; Konieczny A; Szewczuk Z
    Molecules; 2020 Mar; 25(7):. PubMed ID: 32225084
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Facile synthesis of deuterium-labeled denatonium cation and its application in the quantitative analysis of Bitrex by liquid chromatography-mass spectrometry.
    Bąchor R; Kluczyk A; Stefanowicz P; Szewczuk Z
    Anal Bioanal Chem; 2015 Aug; 407(21):6557-61. PubMed ID: 26077748
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preparation of Deuterium-Labeled Armodafinil by Hydrogen-Deuterium Exchange and Its Application in Quantitative Analysis by LC-MS.
    Grocholska P; Wieczorek R; Bąchor R
    Metabolites; 2022 Jun; 12(7):. PubMed ID: 35888702
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Trends in the Hydrogen-Deuterium Exchange at the Carbon Centers. Preparation of Internal Standards for Quantitative Analysis by LC-MS.
    Grocholska P; Bąchor R
    Molecules; 2021 May; 26(10):. PubMed ID: 34069879
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Convenient preparation of deuterium-labeled analogs of peptides containing N-substituted glycines for a stable isotope dilution LC-MS quantitative analysis.
    Bąchor R; Dębowski D; Łęgowska A; Stefanowicz P; Rolka K; Szewczuk Z
    J Pept Sci; 2015 Nov; 21(11):819-25. PubMed ID: 26415697
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).
    Fernández-Fernández M; Rodríguez-González P; Añón Álvarez ME; Rodríguez F; Menéndez FV; García Alonso JI
    Anal Chem; 2015 Apr; 87(7):3755-63. PubMed ID: 25751287
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The hydrogen-deuterium exchange at α-carbon atom in N,N,N-trialkylglycine residue: ESI-MS studies.
    Rudowska M; Wojewska D; Kluczyk A; Bąchor R; Stefanowicz P; Szewczuk Z
    J Am Soc Mass Spectrom; 2012 Jun; 23(6):1024-8. PubMed ID: 22403022
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of isotope dilution-liquid chromatography/mass spectrometry combined with standard addition techniques for the accurate determination of tocopherols in infant formula.
    Lee J; Jang ES; Kim B
    Anal Chim Acta; 2013 Jul; 787():132-9. PubMed ID: 23830431
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.
    Nah H; Lee SG; Lee KS; Won JH; Kim HO; Kim JH
    Clin Biochem; 2016 Feb; 49(3):274-81. PubMed ID: 26519089
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.
    Tai SS; Welch MJ
    Anal Chem; 2004 Feb; 76(4):1008-14. PubMed ID: 14961732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stable isotope labeling assisted liquid chromatography-electrospray tandem mass spectrometry for quantitative analysis of endogenous gibberellins.
    Hao YH; Zhang Z; Wang L; Liu C; Lei AW; Yuan BF; Feng YQ
    Talanta; 2015 Nov; 144():341-8. PubMed ID: 26452831
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous and rapid analysis of cyclosporin A and creatinine in finger prick blood samples using liquid chromatography tandem mass spectrometry and its application in C2 monitoring.
    Keevil BG; Tierney DP; Cooper DP; Morris MR; Machaal A; Yonan N
    Ther Drug Monit; 2002 Dec; 24(6):757-67. PubMed ID: 12451294
    [TBL] [Abstract][Full Text] [Related]  

  • 13. LC-MS/MS Method for Serum Creatinine: Comparison with Enzymatic Method and Jaffe Method.
    Ou M; Song Y; Li S; Liu G; Jia J; Zhang M; Zhang H; Yu C
    PLoS One; 2015; 10(7):e0133912. PubMed ID: 26207996
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Facile preparation of deuterium-labeled standards of indole-3-acetic acid (IAA) and its metabolites to quantitatively analyze the disposition of exogenous IAA in Arabidopsis thaliana.
    Kai K; Nakamura S; Wakasa K; Miyagawa H
    Biosci Biotechnol Biochem; 2007 Aug; 71(8):1946-54. PubMed ID: 17690468
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of creatinine in human urine with flow injection tandem mass spectrometry.
    Niesser M; Koletzko B; Peissner W
    Ann Nutr Metab; 2012; 61(4):314-21. PubMed ID: 23208161
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synthesis of deuterium-labelled fluorobenzoic acids to be used as internal standards in isotope dilution mass spectrometry.
    Müller K; Seubert A
    Isotopes Environ Health Stud; 2014; 50(1):88-93. PubMed ID: 24499142
    [TBL] [Abstract][Full Text] [Related]  

  • 17.
    Hermann G; Schwaiger M; Volejnik P; Koellensperger G
    J Pharm Biomed Anal; 2018 Jun; 155():329-334. PubMed ID: 29704823
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Synthesis of 3α-deuterated 7α-hydroxy-DHEA and 7-oxo-DHEA and application in LC-MS/MS plasma analysis.
    Kolatorova Sosvorova L; Sarek J; Vitku J; Kvasnica M
    Steroids; 2016 Aug; 112():88-94. PubMed ID: 27192427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative O-glycomics based on improvement of the one-pot method for nonreductive O-glycan release and simultaneous stable isotope labeling with 1-(d
    Wang C; Zhang P; Jin W; Li L; Qiang S; Zhang Y; Huang L; Wang Z
    J Proteomics; 2017 Jan; 150():18-30. PubMed ID: 27585995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. ¹³C labelled internal standards--a solution to minimize ion suppression effects in liquid chromatography-tandem mass spectrometry analyses of drugs in biological samples?
    Berg T; Strand DH
    J Chromatogr A; 2011 Dec; 1218(52):9366-74. PubMed ID: 22119139
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.