These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 32225787)

  • 1. System design and error correction for 300  mm aperture vertical Fizeau spatial-temporal phase-shifting interferometer.
    Zheng D; Chen L; Kong L; Wang C; Hu C; Wang Y; Zhu W; Zhu R; Wulan T
    Appl Opt; 2020 Mar; 59(8):2513-2520. PubMed ID: 32225787
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of the surface form error of large aperture plane optical surfaces with a polarization phase-shifting liquid reference reflection Fizeau interferometer.
    Chatterjee S; Kumar YP; Singh R; Singh S
    Appl Opt; 2016 Jan; 55(2):310-6. PubMed ID: 26835767
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of surface form error of an optical surface with reduced interferometric spatial coherence artifacts using a ring source and polarization phase-shifting interferometry.
    Pavan Kumar Y; Negi SS; Kamath MP; Chatterjee S; Sharma SD
    Appl Opt; 2016 Dec; 55(35):10053-10059. PubMed ID: 27958420
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Phase-shifting laser diode interferometer using pulse modulation.
    Suzuki T; Adachi T; Sasaki O; Choi S
    Appl Opt; 2012 Jun; 51(18):4109-12. PubMed ID: 22722287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modelling and correction for polarization errors of a 600 mm aperture dynamic Fizeau interferometer.
    Miao X; Ma J; Yu Y; Li J; Wei C; Zhu R; Chen L; Yuan C; Wang Q; Zheng D
    Opt Express; 2020 Oct; 28(22):33355-33370. PubMed ID: 33115002
    [TBL] [Abstract][Full Text] [Related]  

  • 6. System design and error correction of simultaneous phase-shifting point-diffraction interferometer for dynamic wavefront detection with 400  mm aperture.
    Zheng D; Ma Z; Zhang Z; Hu C
    Appl Opt; 2023 Jan; 62(3):745-755. PubMed ID: 36821280
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous measurement of the surface shape and thickness for an optical flat with a wavelength-tuning Fizeau interferometer with suppression of drift error.
    Kim Y; Moon Y; Hibino K; Sugita N; Mitsuishi M
    Appl Opt; 2020 Feb; 59(4):991-997. PubMed ID: 32225236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of birefringence on Fizeau interferometry that uses a polarization phase-shifting technique.
    Zhao C; Kang D; Burge JH
    Appl Opt; 2005 Dec; 44(35):7548-53. PubMed ID: 16363779
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Phase-shifting interferometer using a frequency-tunable diode laser calibrated by an optical frequency comb.
    Wu X; Zhang J; Wei H; Li Y
    Rev Sci Instrum; 2012 Jul; 83(7):073107. PubMed ID: 22852671
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interferometric profile measurement of optical-thickness by wavelength tuning with suppression of spatially uniform error.
    Kim Y; Hibino K; Mitsuishi M
    Opt Express; 2018 Apr; 26(8):10870-10878. PubMed ID: 29716017
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Separate measurements of surface shapes and refractive index inhomogeneity of an optical element using tunable-source phase shifting interferometry.
    Okada K; Sakuta H; Ose T; Tsujiuchi J
    Appl Opt; 1990 Aug; 29(22):3280-5. PubMed ID: 20567410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correlated errors in phase-shifting laser Fizeau interferometry.
    de Groot PJ
    Appl Opt; 2014 Jul; 53(19):4334-42. PubMed ID: 25089998
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of phase measurement error sources in phase-shifting interferometry with four step phase-shifting algorithms.
    Pak IJ; Kim CS; Kang JC; Son JR
    Appl Opt; 2021 May; 60(13):3856-3864. PubMed ID: 33983323
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Iterative deformation calibration of a transmission flat via the ring-point support on a 300-mm-aperture vertical Fizeau interferometer.
    Wang Y; Chen L; Hu C; Chen J; Zhang Z; Zheng D; Wulan T
    Opt Express; 2021 Feb; 29(3):2984-3000. PubMed ID: 33770907
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Random-phase-shift Fizeau interferometer.
    Broistedt H; Doloca NR; Strube S; Tutsch R
    Appl Opt; 2011 Dec; 50(36):6564-75. PubMed ID: 22193185
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Femtosecond laser-based phase-shifting interferometry for optical surface measurement.
    Wang Y; Xiong S; Wu G
    Rev Sci Instrum; 2018 Nov; 89(11):113105. PubMed ID: 30501301
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-wavelength phase-shifting interferometry insensitive to the intensity modulation of dual laser diodes.
    Onodera R; Ishii Y
    Appl Opt; 1994 Aug; 33(22):5052-61. PubMed ID: 20935887
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Iterative full-bandwidth wavefront reconstruction from a set of low-tilt Fizeau interferograms for high-numerical-aperture surface characterization.
    Heil J; Bauer T; Sure T; Wesner J
    Appl Opt; 2006 Jun; 45(18):4270-83. PubMed ID: 16778935
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic Fizeau interferometer with assistant defocused source.
    Duan M; Li J; Zong Y; Yu C
    Opt Lett; 2022 Mar; 47(6):1557-1560. PubMed ID: 35290363
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of a 300-mm-aperture phase-shifting Fizeau interferometer.
    Oreb BB; Farrant DI; Walsh CJ; Forbes G; Fairman PS
    Appl Opt; 2000 Oct; 39(28):5161-71. PubMed ID: 18354512
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.