These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 32232455)

  • 1. Missing Plasma, Faulty Gel, or Something Else?
    Tsui AKY; Füzéry AK; Szkotak A; Forrest A
    Clin Chem; 2020 Apr; 66(4):625-626. PubMed ID: 32232455
    [No Abstract]   [Full Text] [Related]  

  • 2. Considerably reduced centrifugation time without increased hemolysis: evaluation of the new BD Vacutainer SSTTMII Advance.
    Mensel B; Wenzel U; Roser M; Lüdemann J; Nauck M
    Clin Chem; 2007 Apr; 53(4):794-5. PubMed ID: 17405947
    [No Abstract]   [Full Text] [Related]  

  • 3. The effect of recentrifugation of serum separator tubes on concentration of serum analytes.
    Shafi H; Sadrzadeh H
    Ann Clin Lab Sci; 2012; 42(3):318-9. PubMed ID: 22964622
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High total protein impairs appropriate gel barrier formation in BD Vacutainer blood collection tubes.
    van den Ouweland JM; Church S
    Clin Chem; 2007 Feb; 53(2):364-5. PubMed ID: 17259253
    [No Abstract]   [Full Text] [Related]  

  • 5. Centrifugation protocols: tests to determine optimal lithium heparin and citrate plasma sample quality.
    Dimeski G; Solano C; Petroff MK; Hynd M
    Ann Clin Biochem; 2011 May; 48(Pt 3):218-22. PubMed ID: 21398434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a reduced centrifugation time and higher centrifugal force on various general chemistry and immunochemistry analytes in plasma and serum.
    Møller MF; Søndergaard TR; Kristensen HT; Münster AB
    Ann Clin Biochem; 2017 Sep; 54(5):593-600. PubMed ID: 27687083
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
    Balboni F; Burbui S; Lippi G
    Scand J Clin Lab Invest; 2018; 78(7-8):546-550. PubMed ID: 30755098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Standardization of methods for the preparation of blood components: examination of the operational characteristics of various centrifuges].
    Raffaldoni E; Ghessi A
    Rev Fr Transfus Immunohematol; 1986 Apr; 29(2):107-20. PubMed ID: 3749718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical trials of a novel centrifugation method: axial separation.
    Estey CA; Felder RA
    Clin Chem; 1996 Mar; 42(3):402-9. PubMed ID: 8598103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Importance of preanalytical step in hemostasis].
    Ellouze R; Guermazi S
    Ann Biol Clin (Paris); 2013; 71(4):401-7. PubMed ID: 23906567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A device for balancing the cups in donor blood centrifugation].
    Golosova SA; Samburskiĭ AI; Zhiburt EB
    Med Tekh; 2004; (1):41-2. PubMed ID: 15080008
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of hemolysis during sample collection: how different is drug concentration in hemolyzed plasma from that of normal plasma?
    Tan A; Gagné S; Lévesque IA; Lachance S; Boudreau N; Lévesque A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jul; 901():79-84. PubMed ID: 22748717
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stability of serum samples and hemolysis interference on the high sensitivity troponin T assay.
    Li A; Brattsand G
    Clin Chem Lab Med; 2011 Feb; 49(2):335-6. PubMed ID: 21077790
    [No Abstract]   [Full Text] [Related]  

  • 14. An unusual case of a primary blood collection tube with floating separator gel.
    Daves M; Lippi G; Cosio G; Raffagnini A; Peer E; Dangella A; Oberhollenzer R; Cemin R
    J Clin Lab Anal; 2012 Jul; 26(4):246-7. PubMed ID: 22811356
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of BD Vacutainer PST II tubes for a wide range of immunoassays.
    Giavarina D; Fortunato A; Barzon E; Church S; Bérubé J; Green S; Soffiati G
    Clin Chem Lab Med; 2009; 47(2):237-41. PubMed ID: 19191732
    [No Abstract]   [Full Text] [Related]  

  • 16. What´s floating on my plasma?
    Cadamuro J; Wiedemann H; Felder TK; Mrazek C; Kipman U; Hannes O; Haschke-Becher E
    Biochem Med (Zagreb); 2017 Jun; 27(2):430-433. PubMed ID: 28694735
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Methodological considerations for the accurate determination of lead in human plasma and serum.
    Smith DR; Ilustre RP; Osterloh JD
    Am J Ind Med; 1998 May; 33(5):430-8. PubMed ID: 9557166
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemolysis interference in measuring fish plasma biochemical indicators.
    Mirghaed AT; Ghelichpour M; Hoseini SM; Amini K
    Fish Physiol Biochem; 2017 Aug; 43(4):1143-1151. PubMed ID: 28293862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Blood venous sample collection: Recommendations overview and a checklist to improve quality.
    Giavarina D; Lippi G
    Clin Biochem; 2017 Jul; 50(10-11):568-573. PubMed ID: 28242283
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of a serum separator device for obtaining serum specimens suitable for clinical analyses.
    Laessig RH; Westgard JO; Carey RN; Hassemer DJ; Schwartz TH; Feldbruegge DH
    Clin Chem; 1976 Feb; 22(2):235-9. PubMed ID: 1248126
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.