These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 32233135)

  • 21. Additional work of breathing imposed by endotracheal tubes, breathing circuits, and intensive care ventilators.
    Bersten AD; Rutten AJ; Vedig AE; Skowronski GA
    Crit Care Med; 1989 Jul; 17(7):671-7. PubMed ID: 2736929
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Potential inadequacy of automatic tube compensation to decrease inspiratory work load after at least 48 hours of endotracheal tube use in the clinical setting.
    Oto J; Imanaka H; Nakataki E; Ono R; Nishimura M
    Respir Care; 2012 May; 57(5):697-703. PubMed ID: 22153219
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Resistance of pediatric and neonatal endotracheal tubes: influence of flow rate, size, and shape.
    Manczur T; Greenough A; Nicholson GP; Rafferty GF
    Crit Care Med; 2000 May; 28(5):1595-8. PubMed ID: 10834718
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of supraglottic airway device use during inhalation anesthesia in healthy African pygmy hedgehogs (Atelerix albiventris).
    Huckins GL; Doss GA; Ferreira TH
    Vet Anaesth Analg; 2021 Jul; 48(4):517-523. PubMed ID: 33903071
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Elevations in End-Tidal CO 2 With CO 2 Use During Pediatric Endoscopy With Airway Protection: Is This Physiologically Significant?
    Dike CR; Huang Pacheco A; Lyden E; Freestone D; Choudhry O; Bishop WP; Shukry M
    J Pediatr Gastroenterol Nutr; 2023 May; 76(5):660-666. PubMed ID: 36821847
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prospective comparison of use of the laryngeal mask and endotracheal tube for ambulatory surgery.
    Cork RC; Depa RM; Standen JR
    Anesth Analg; 1994 Oct; 79(4):719-27. PubMed ID: 7943782
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of the EasyTube and endotracheal tube during general anesthesia in fasted adult patients.
    Lorenz V; Rich JM; Schebesta K; Taslakian S; Müllner M; Frass M; Schuster E; Illievich UM; Kaye AD; Vaida S; Krafft P
    J Clin Anesth; 2009 Aug; 21(5):341-7. PubMed ID: 19700284
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of Endotracheal Tube Scraping on Airway Resistance.
    Scott JB; Dubosky MN; Vines DL; Sulaiman AS; Jendral KR; Singh G; Patel A; Kaplan CA; Gurka DP; Balk RA
    Respir Care; 2017 Nov; 62(11):1423-1427. PubMed ID: 28790149
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The laryngeal tube for difficult airway management: a prospective investigation in patients with pharyngeal and laryngeal tumours.
    Winterhalter M; Kirchhoff K; Gröschel W; Lüllwitz E; Heermann R; Hoy L; Heine J; Hagberg C; Piepenbrock S
    Eur J Anaesthesiol; 2005 Sep; 22(9):678-82. PubMed ID: 16163914
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of the laryngeal mask airway ProSeal and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation.
    Brimacombe J; Keller C; Brimacombe L
    Anesth Analg; 2002 Sep; 95(3):770-6, table of contents. PubMed ID: 12198070
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Physiological dead space/tidal volume ratio during face mask, laryngeal mask, and cuffed oropharyngeal airway spontaneous ventilation.
    Casati A; Fanelli G; Torri G
    J Clin Anesth; 1998 Dec; 10(8):652-5. PubMed ID: 9873966
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model.
    Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
    BMC Anesthesiol; 2016 Jun; 16(1):30. PubMed ID: 27350249
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Added work of breathing, respiratory pattern and determination of ventilator weaning readiness in inspiratory pressure support and and automatic tube compensation].
    Stocker R; Fabry B; Stein S; Zappe D; Trentz O; Haberthür C
    Unfallchirurg; 1996 Oct; 99(10):764-70. PubMed ID: 9005565
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of the cuffed oropharyngeal airway (COPA) with the laryngeal mask airway (LMA) during manually controlled positive pressure ventilation.
    Heringlake M; Doerges V; Ocker H; Schmucker P
    J Clin Anesth; 1999 Nov; 11(7):590-5. PubMed ID: 10624645
    [TBL] [Abstract][Full Text] [Related]  

  • 35. I-Gel is a suitable alternative to endotracheal tubes in the laparoscopic pneumoperitoneum and trendelenburg position.
    Lai CJ; Liu CM; Wu CY; Tsai FF; Tseng PH; Fan SZ
    BMC Anesthesiol; 2017 Jan; 17(1):3. PubMed ID: 28125979
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Supraglottic airway device placement by respiratory therapists.
    Heegeman DJ; Rosandick WD; Boehning-Anderson RH; Woltmann AR
    Am J Emerg Med; 2018 Oct; 36(10):1845-1848. PubMed ID: 30097274
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ventilator Y-piece pressure compared with intratracheal airway pressure in healthy intubated children.
    Nasiroglu O; Weldon BC; Berman LS; Haque IU
    J Clin Monit Comput; 2006 Apr; 20(2):95-100. PubMed ID: 16779622
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of respiratory system resistance in mechanically ventilated patients: the role of the endotracheal tube.
    Conti G; De Blasi RA; Lappa A; Ferretti A; Antonelli M; Bufi M; Gasparetto A
    Intensive Care Med; 1994 Jul; 20(6):421-4. PubMed ID: 7798446
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A comparison of a new, ultrathin-walled two-stage twin endotracheal tube and a conventional endotracheal tube in very premature infants with respiratory distress syndrome: a pilot study.
    Parravicini E; Baccarelli A; Wung JT; Kolobow T; Lorenz JM
    Am J Perinatol; 2007 Feb; 24(2):117-22. PubMed ID: 17304419
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.