BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 32235251)

  • 1. Clinical comparison of 27-gauge and 23-gauge instruments on the outcomes of pars plana vitrectomy surgery for the treatment of vitreoretinal diseases.
    Charles S; Ho AC; Dugel PU; Riemann CD; Berrocal MH; Gupta S; Hamilton C; Abulon DJK
    Curr Opin Ophthalmol; 2020 May; 31(3):185-191. PubMed ID: 32235251
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 23-Gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial.
    Wimpissinger B; Kellner L; Brannath W; Krepler K; Stolba U; Mihalics C; Binder S
    Br J Ophthalmol; 2008 Nov; 92(11):1483-7. PubMed ID: 18703552
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of 27-gauge versus 25-gauge vitrectomy results in patients with epiretinal membrane: 6-month follow-up.
    Lubiński W; Gosławski W; Podborączyńska-Jodko K; Mularczyk M; Post M
    Int Ophthalmol; 2020 Apr; 40(4):867-875. PubMed ID: 31956931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Short-term outcomes of 23-gauge pars plana vitrectomy.
    Gupta OP; Ho AC; Kaiser PK; Regillo CD; Chen S; Dyer DS; Dugel PU; Gupta S; Pollack JS
    Am J Ophthalmol; 2008 Aug; 146(2):193-197. PubMed ID: 18547538
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Faster visual recovery after 23-gauge vitrectomy compared with 20-gauge vitrectomy.
    Narayanan R; Sinha A; Reddy RK; Krishnaiah S; Kuppermann BD
    Retina; 2010 Oct; 30(9):1511-4. PubMed ID: 20829739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 23-gauge vitrectomy in 100 eyes: short-term visual outcomes and complications.
    Lott MN; Manning MH; Singh J; Zhang H; Singh H; Marcus DM
    Retina; 2008 Oct; 28(9):1193-200. PubMed ID: 18626419
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 25-, 23-, and 20-gauge vitrectomy in epiretinal membrane surgery: a comparative study of 553 cases.
    Sandali O; El Sanharawi M; Lecuen N; Barale PO; Bonnel S; Basli E; Borderie V; Laroche L; Monin C
    Graefes Arch Clin Exp Ophthalmol; 2011 Dec; 249(12):1811-9. PubMed ID: 21830061
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 25-Gauge transconjunctival sutureless pars plana vitrectomy.
    Yanyali A; Celik E; Horozoglu F; Oner S; Nohutcu AF
    Eur J Ophthalmol; 2006; 16(1):141-7. PubMed ID: 16496259
    [TBL] [Abstract][Full Text] [Related]  

  • 9. LONG-TERM INTRAOCULAR PRESSURE AFTER UNCOMPLICATED PARS PLANA VITRECTOMY FOR IDIOPATHIC EPIRETINAL MEMBRANE.
    Tognetto D; Pastore MR; Cirigliano G; DʼAloisio R; Borelli M; De Giacinto C
    Retina; 2019 Jan; 39(1):163-171. PubMed ID: 29160783
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 27-gauge and 25-gauge vitrectomy day surgery for idiopathic epiretinal membrane.
    Naruse S; Shimada H; Mori R
    BMC Ophthalmol; 2017 Oct; 17(1):188. PubMed ID: 29017460
    [TBL] [Abstract][Full Text] [Related]  

  • 11. SURGICAL OUTCOMES IN PATIENTS WITH MACULAR PUCKER AND GOOD PREOPERATIVE VISUAL ACUITY AFTER VITRECTOMY WITH MEMBRANE PEELING.
    Reilly G; Melamud A; Lipscomb P; Toussaint B
    Retina; 2015 Sep; 35(9):1817-21. PubMed ID: 25923959
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of safety and effectiveness between 23-gauge and 25-gauge vitrectomy surgery in common vitreoretinal diseases.
    Sedova A; Steiner I; Matzenberger RP; Georgopoulos M; Scholda C; Kriechbaum KF; Abela-Formanek C; Mylonas G; Sacu S; Schmidt-Erfurth U; Pollreisz A
    PLoS One; 2021; 16(3):e0248164. PubMed ID: 33667273
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 25-gauge vs 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial.
    Kellner L; Wimpissinger B; Stolba U; Brannath W; Binder S
    Br J Ophthalmol; 2007 Jul; 91(7):945-8. PubMed ID: 17202200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Combined 23-gauge vitrectomy and femtosecond laser-assisted cataract surgery.
    Gómez-Resa M; Nieto I; Corcóstegui B
    Ophthalmic Res; 2014; 52(3):141-6. PubMed ID: 25300809
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Postoperative complications associated with 25-gauge pars plana vitrectomy.
    Gupta OP; Weichel ED; Regillo CD; Fineman MS; Kaiser RS; Ho AC; McNamara JA; Vander JE
    Ophthalmic Surg Lasers Imaging; 2007; 38(4):270-5. PubMed ID: 17674916
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative study between a standard 25-gauge vitrectomy system and a new ultrahigh-speed 25-gauge system with duty cycle control in the treatment of various vitreoretinal diseases.
    Rizzo S; Genovesi-Ebert F; Belting C
    Retina; 2011 Nov; 31(10):2007-13. PubMed ID: 21685823
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery.
    Fujii GY; De Juan E; Humayun MS; Pieramici DJ; Chang TS; Awh C; Ng E; Barnes A; Wu SL; Sommerville DN
    Ophthalmology; 2002 Oct; 109(10):1807-12; discussion 1813. PubMed ID: 12359598
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes.
    Valmaggia C
    Klin Monbl Augenheilkd; 2007 Apr; 224(4):292-6. PubMed ID: 17458795
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Study of intraocular pressure after 23-gauge and 25-gauge pars plana vitrectomy randomized to fluid versus air fill.
    Ho LY; Garretson BR; Ranchod TM; Balasubramaniam M; Ruby AJ; Capone A; Drenser KA; Williams GA; Hassan TS
    Retina; 2011 Jun; 31(6):1109-17. PubMed ID: 21358360
    [TBL] [Abstract][Full Text] [Related]  

  • 20. COMPARISON OF SURGICAL OUTCOME OF 23-GAUGE AND 25-GAUGE MICROINCISION VITRECTOMY SURGERY FOR MANAGEMENT OF IDIOPATHIC EPIRETINAL MEMBRANE IN PSEUDOPHAKIC EYES.
    Kim M; Park YS; Lee DH; Koh HJ; Lee SC; Kim SS
    Retina; 2015 Oct; 35(10):2115-20. PubMed ID: 25978731
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.