These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 32236536)

  • 1. Preoperative determination of artificial chordae tendineae length by transoesophageal echocardiography in totally endoscopic mitral valve repair.
    Pitsis A; Tsotsolis N; Theofilogiannakos E; Boudoulas H; Boudoulas KD
    Interact Cardiovasc Thorac Surg; 2020 Jul; 31(1):20-27. PubMed ID: 32236536
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimizing P2 Neochordal Length and Stability in Mitral Valve Repair With Use of a Polypropylene Loop.
    Ozen A; Unal EU; Ozbek HM; Yigit G; Iscan HZ
    Tex Heart Inst J; 2020 Jun; 47(3):207-209. PubMed ID: 32997772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair.
    Huang HL; Xie XJ; Fei HW; Xiao XJ; Liu J; Zhuang J; Lu C
    J Cardiothorac Surg; 2013 May; 8():137. PubMed ID: 23721153
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Artificial chordae.
    David TE
    Semin Thorac Cardiovasc Surg; 2004; 16(2):161-8. PubMed ID: 15197692
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intermittent tethering of second-order chords after mitral valve repair for bileaflet prolapse.
    Iacò AL; Ahmed AA; Al Zaharani G; Al Amri H; Di Mauro M; Calafiore AM
    Ann Thorac Surg; 2013 Dec; 96(6):e145-6. PubMed ID: 24296225
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ten-year experience of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair.
    Kobayashi J; Sasako Y; Bando K; Minatoya K; Niwaya K; Kitamura S
    Circulation; 2000 Nov; 102(19 Suppl 3):III30-4. PubMed ID: 11082358
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Six-year outcomes after non-resective mitral valve repair with artificial chordae using removable clips.
    Chopard R; Perrotti A; Durst C; Meneveau N; Stoica LL; Chocron S
    J Heart Valve Dis; 2014 May; 23(3):364-9. PubMed ID: 25296463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Artificial chordae in the treatment of anterior mitral leaflet pathology.
    Zussa C; Polesel E; Rocco F; Valfrè C
    Cardiovasc Surg; 1997 Feb; 5(1):125-8. PubMed ID: 9158134
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characteristics and treatment strategies of mitral regurgitation associated with undifferentiated papillary muscle.
    Matsumaru I; Hashizume K; Ariyoshi T; Izumi K; Onohara D; Nakaji S; Sumi M; Eishi K; Tsuneto A; Hayashi T
    Gen Thorac Cardiovasc Surg; 2012 Jul; 60(7):406-10. PubMed ID: 22576650
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simple way to treat mitral valve prolapse: chordal replacement using a new mitral leaflet retractor.
    Kashiyama N; Masai T; Yoshitatsu M; Yamauchi T; Ogasawara Y; Matsunaga Y; Sawa Y
    Interact Cardiovasc Thorac Surg; 2014 Jun; 18(6):701-5. PubMed ID: 24608729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple method to obtain the correct length of the artificial chordae in complex chordal replacement.
    Calafiore AM; Scandura S; Iacò AL; Contini M; Di Mauro M; Bivona A; Giordano G; Bosco P
    J Card Surg; 2008; 23(3):204-6. PubMed ID: 18435632
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Midterm results of mitral valve repair with artificial chordae in children.
    Minami K; Kado H; Sai S; Tatewaki H; Shiokawa Y; Nakashima A; Fukae K; Hirose H
    J Thorac Cardiovasc Surg; 2005 Feb; 129(2):336-42. PubMed ID: 15678044
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simplifying Mitral Valve Repair: A Guide to Neochordae Reconstruction.
    Montanhesi PK; Ghoneim A; Gelinas J; Chu MWA
    Innovations (Phila); 2022; 17(4):343-351. PubMed ID: 35997684
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A 25-year study of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair†.
    Hata H; Fujita T; Shimahara Y; Sato S; Ishibashi-Ueda H; Kobayashi J
    Interact Cardiovasc Thorac Surg; 2015 Apr; 20(4):463-8; discussion 468. PubMed ID: 25547921
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Seamless reconstruction of mitral leaflet and chordae with one piece of pericardium.
    Ito T; Maekawa A; Aoki M; Hoshino S; Hayashi Y; Sawaki S; Yanagisawa J; Tokoro M
    Eur J Cardiothorac Surg; 2014 Jun; 45(6):e227-32. PubMed ID: 24692406
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of artificial neochordae and native chordal transfer in the repair of a flail posterior mitral leaflet: an experimental study.
    Padala M; Cardinau B; Gyoneva LI; Thourani VH; Yoganathan AP
    Ann Thorac Surg; 2013 Feb; 95(2):629-33. PubMed ID: 23291143
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes of mitral valve repair using artificial chordae.
    Ibrahim M; Rao C; Savvopoulou M; Casula R; Athanasiou T
    Eur J Cardiothorac Surg; 2014 Apr; 45(4):593-601. PubMed ID: 23990619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mitral valve repair by replacement of chordae tendineae with polytetrafluoroethylene sutures.
    David TE; Bos J; Rakowski H
    J Thorac Cardiovasc Surg; 1991 Mar; 101(3):495-501. PubMed ID: 1999944
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple method of making artificial chordal loops for mitral valve repair.
    Cagli K
    Ann Thorac Surg; 2010 Feb; 89(2):e12-4. PubMed ID: 20103293
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intracardiac calipers for artificial chordae replacement in mitral valve repair.
    Doi A; Iida H; Sunazawa T
    Ann Thorac Surg; 2009 Jan; 87(1):326-8. PubMed ID: 19101333
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.