These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 32244849)

  • 1. A Novel Hydraulic Actuation System Utilizing Magnetorheological Fluids for Single-Port Laparoscopic Surgery Applications.
    El Wahed AK
    Materials (Basel); 2020 Mar; 13(6):. PubMed ID: 32244849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-performance magneto-rheological clutches for direct-drive actuation: Design and development.
    Pisetskiy S; Kermani M
    J Intell Mater Syst Struct; 2021 Dec; 32(20):2582-2600. PubMed ID: 34764629
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Highly-Integrated Hydraulic Smart Actuators and Smart Manifolds for High-Bandwidth Force Control.
    Barasuol V; Villarreal-Magaña OA; Sangiah D; Frigerio M; Baker M; Morgan R; Medrano-Cerda GA; Caldwell DG; Semini C
    Front Robot AI; 2018; 5():51. PubMed ID: 33659276
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental assessment of a linear actuator driven by magnetorheological clutches for automotive active suspensions.
    East W; Turcotte J; Plante JS; Julio G
    J Intell Mater Syst Struct; 2021 May; 32(9):955-970. PubMed ID: 34040332
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sensors and Sensing Devices Utilizing Electrorheological Fluids and Magnetorheological Materials-A Review.
    Park YJ; Choi SB
    Sensors (Basel); 2024 Apr; 24(9):. PubMed ID: 38732948
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and development of magnetorheological fluid-based passive actuator.
    Shokrollahi E; Price K; Drake JM; Goldenberg AA
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():4883-6. PubMed ID: 26737387
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An Unconventional Inchworm Actuator Based on PZT/ERFs Control Technology.
    Liu G; Zhang Y; Liu J; Li J; Tang C; Wang T; Yang X
    Appl Bionics Biomech; 2016; 2016():2804543. PubMed ID: 27022234
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design optimization and experimental evaluation of a large capacity magnetorheological damper with annular and radial fluid gaps.
    Abdalaziz M; Sedaghati R; Vatandoost H
    J Intell Mater Syst Struct; 2023 Aug; 34(14):1646-1663. PubMed ID: 37521729
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Position and torque tracking: series elastic actuation versus model-based-controlled hydraulic actuation.
    Otten A; van Vuuren W; Stienen A; van Asseldonk E; Schouten A; van der Kooij H
    IEEE Int Conf Rehabil Robot; 2011; 2011():5975456. PubMed ID: 22275654
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A New Type of Hydraulic Clutch with Magnetorheological Fluid: Theory and Experiment.
    Musiałek K; Musiałek I; Osowski K; Olszak A; Mikulska A; Kęsy Z; Kęsy A; Choi SB
    Micromachines (Basel); 2024 Apr; 15(5):. PubMed ID: 38793145
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization and demonstration of two types of spring-roll dielectric elastomer actuators for minimally invasive surgery.
    Wang H; Cui S; Niu F
    Front Bioeng Biotechnol; 2022; 10():1016350. PubMed ID: 36267447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Searching for a Stable High-Performance Magnetorheological Suspension.
    Seo YP; Han S; Choi J; Takahara A; Choi HJ; Seo Y
    Adv Mater; 2018 Oct; 30(42):e1704769. PubMed ID: 30151957
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coupled Field Analysis of Phenomena in Hybrid Excited Magnetorheological Fluid Brake.
    Szelag W; Jedryczka C; Myszkowski A; Wojciechowski RM
    Sensors (Basel); 2022 Dec; 23(1):. PubMed ID: 36616957
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reinforcing Magnetorheological Fluids with Highly Anisotropic 2D Materials.
    Rendos A; Li R; Woodman S; Ling X; Brown KA
    Chemphyschem; 2021 Mar; 22(5):435-440. PubMed ID: 33354890
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Active catheter driven by a thermo-hydraulic actuation.
    Horovitz Y; Kosa G
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():7772-5. PubMed ID: 26738094
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Synthesis of Organic Oils Blended Magnetorheological Fluids with the Field-Dependent Material Characterization.
    Jinaga R; Jagadeesha T; Kolekar S; Choi SB
    Int J Mol Sci; 2019 Nov; 20(22):. PubMed ID: 31744101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Special section on biomimetics of movement.
    Carpi F; Erb R; Jeronimidis G
    Bioinspir Biomim; 2011 Dec; 6(4):040201. PubMed ID: 22128305
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Robot-assisted Sistrunk's operation, total thyroidectomy, and neck dissection via a transaxillary and retroauricular (TARA) approach in papillary carcinoma arising in thyroglossal duct cyst and thyroid gland.
    Byeon HK; Ban MJ; Lee JM; Ha JG; Kim ES; Koh YW; Choi EC
    Ann Surg Oncol; 2012 Dec; 19(13):4259-61. PubMed ID: 23070784
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single-Incision Laparoscopic Cholecystectomy Using Conventional Laparoscopic Instruments and Comparison with Three-Port Cholecystectomy.
    Singh M; Mehta KS; Yasir M; Kaur A; Aiman A; Sharma A; Kaur N
    Indian J Surg; 2015 Dec; 77(Suppl 2):546-50. PubMed ID: 26730062
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modeling and test of a kinaesthetic actuator based on MR fluid for haptic applications.
    Yang TH; Koo JH; Kim SY; Kwon DS
    Rev Sci Instrum; 2017 Mar; 88(3):035004. PubMed ID: 28372429
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.