These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 32250642)

  • 21. CT-like MRI using the zero-TE technique for osseous changes of the TMJ.
    Lee C; Jeon KJ; Han SS; Kim YH; Choi YJ; Lee A; Choi JH
    Dentomaxillofac Radiol; 2020 Mar; 49(3):20190272. PubMed ID: 31670578
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans.
    Veldhoen S; Schöllchen M; Hanken H; Precht C; Henes FO; Schön G; Nagel HD; Schumacher U; Heiland M; Adam G; Regier M
    Eur Radiol; 2017 Feb; 27(2):790-800. PubMed ID: 27169574
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols.
    Kim S; Yoo S; Yin FF; Samei E; Yoshizumi T
    Med Phys; 2010 Jul; 37(7):3648-59. PubMed ID: 20831072
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hand-wrist, knee, and foot-ankle dosimetry and image quality measurements of a novel extremity imaging unit providing CBCT and 2D imaging options.
    Ludlow JB
    Med Phys; 2018 Nov; 45(11):4955-4963. PubMed ID: 30229941
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Assessment of a training programme on detection of temporomandibular joint osseous changes applying pre-defined 2D multiplane cone beam computed tomography reconstructions.
    Iskanderani D; Alstergren P; Hellén-Halme K
    J Oral Rehabil; 2018 Apr; 45(4):282-288. PubMed ID: 29377222
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Diagnostic accuracy of 2 cone-beam computed tomography protocols for detecting arthritic changes in temporomandibular joints.
    Yadav S; Palo L; Mahdian M; Upadhyay M; Tadinada A
    Am J Orthod Dentofacial Orthop; 2015 Mar; 147(3):339-44. PubMed ID: 25726401
    [TBL] [Abstract][Full Text] [Related]  

  • 27. MRI and CBCT image registration of temporomandibular joint: a systematic review.
    Al-Saleh MA; Alsufyani NA; Saltaji H; Jaremko JL; Major PW
    J Otolaryngol Head Neck Surg; 2016 May; 45(1):30. PubMed ID: 27164975
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography.
    Honey OB; Scarfe WC; Hilgers MJ; Klueber K; Silveira AM; Haskell BS; Farman AG
    Am J Orthod Dentofacial Orthop; 2007 Oct; 132(4):429-38. PubMed ID: 17920495
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A preliminary study on the registration of MRI and cone beam CT images of temporomandibular joint disc].
    He YM; Wang HY; Feng YP; Li HM; Fang W; Ke J; Long X
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2020 Oct; 55(10):772-777. PubMed ID: 33045790
    [No Abstract]   [Full Text] [Related]  

  • 30. Technical assessment of a cone-beam CT scanner for otolaryngology imaging: image quality, dose, and technique protocols.
    Xu J; Reh DD; Carey JP; Mahesh M; Siewerdsen JH
    Med Phys; 2012 Aug; 39(8):4932-42. PubMed ID: 22894419
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Detection accuracy of condylar defects in cone beam CT images scanned with different resolutions and units.
    Zhang ZL; Shi XQ; Ma XC; Li G
    Dentomaxillofac Radiol; 2014; 43(3):20130414. PubMed ID: 24408818
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of the effective dose of cone beam CT and multislice CT for temporomandibular joint examinations at optimized exposure levels.
    Kadesjö N; Benchimol D; Falahat B; Näsström K; Shi XQ
    Dentomaxillofac Radiol; 2015; 44(8):20150041. PubMed ID: 26119344
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 3D cone-beam CT of the ankle using a novel twin robotic X-ray system: Assessment of image quality and radiation dose.
    Grunz JP; Kunz AS; Gietzen CH; Weng AM; Veyhl-Wichmann M; Ergün S; Schmitt R; Bley TA; Gassenmaier T
    Eur J Radiol; 2019 Oct; 119():108659. PubMed ID: 31520930
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dose distributions in adult and child head phantoms for panoramic and cone beam computed tomography imaging of the temporomandibular joint.
    Iskanderani D; Nilsson M; Alstergren P; Hellén-Halme K
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2020 Aug; 130(2):200-208. PubMed ID: 32094027
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Radiographic examination of the temporomandibular joint using cone beam computed tomography.
    Tsiklakis K; Syriopoulos K; Stamatakis HC
    Dentomaxillofac Radiol; 2004 May; 33(3):196-201. PubMed ID: 15371321
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative Analysis of Bilateral Temporomandibular Joints in Patients With Unilateral Temporomandibular Joint Complaints Using Cone Beam Computed Tomography.
    Li Y; Wang N; Guo X; Xie M; Zhang J; Lv Y; Han W; Hu M
    J Craniofac Surg; 2015 Nov; 26(8):e773-6. PubMed ID: 26595003
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cone beam computed tomography radiation dose and image quality assessments.
    Lofthag-Hansen S
    Swed Dent J Suppl; 2010; (209):4-55. PubMed ID: 21229915
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cone beam computed tomography in the assessment of TMJ deformity in children with JIA: repeatability of a novel scoring system.
    Augdal TA; Angenete OW; Shi XQ; Säll M; Fischer JM; Nordal E; Rosendahl K
    BMC Oral Health; 2023 Jan; 23(1):12. PubMed ID: 36627622
    [TBL] [Abstract][Full Text] [Related]  

  • 39. CBCT characteristics and interpretation challenges of temporomandibular joint osteoarthritis in a hand osteoarthritis cohort.
    Ottersen MK; Abrahamsson AK; Larheim TA; Arvidsson LZ
    Dentomaxillofac Radiol; 2019 May; 48(4):20180245. PubMed ID: 30633546
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children.
    Hidalgo Rivas JA; Horner K; Thiruvenkatachari B; Davies J; Theodorakou C
    Br J Radiol; 2015 Oct; 88(1054):20150559. PubMed ID: 26279087
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.