These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 32258856)

  • 1. Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.
    Hueso-González F; Bortfeld T
    IEEE Trans Radiat Plasma Med Sci; 2020 Mar; 4(2):170-183. PubMed ID: 32258856
    [TBL] [Abstract][Full Text] [Related]  

  • 2. First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility.
    Hueso-González F; Enghardt W; Fiedler F; Golnik C; Janssens G; Petzoldt J; Prieels D; Priegnitz M; Römer KE; Smeets J; Vander Stappen F; Wagner A; Pausch G
    Phys Med Biol; 2015 Aug; 60(16):6247-72. PubMed ID: 26237433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prompt gamma imaging of proton pencil beams at clinical dose rate.
    Perali I; Celani A; Bombelli L; Fiorini C; Camera F; Clementel E; Henrotin S; Janssens G; Prieels D; Roellinghoff F; Smeets J; Stichelbaut F; Vander Stappen F
    Phys Med Biol; 2014 Oct; 59(19):5849-71. PubMed ID: 25207724
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy.
    Robertson D; Polf JC; Peterson SW; Gillin MT; Beddar S
    Phys Med Biol; 2011 May; 56(10):3047-59. PubMed ID: 21508442
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy- and time-resolved detection of prompt gamma-rays for proton range verification.
    Verburg JM; Riley K; Bortfeld T; Seco J
    Phys Med Biol; 2013 Oct; 58(20):L37-49. PubMed ID: 24077338
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Range verification of passively scattered proton beams using prompt gamma-ray detection.
    Verburg JM; Testa M; Seco J
    Phys Med Biol; 2015 Feb; 60(3):1019-29. PubMed ID: 25585521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Range verification of proton radiotherapy with prompt gamma rays.
    Lau A; Chen Y; Ahmad S
    J Xray Sci Technol; 2013; 21(4):507-14. PubMed ID: 24191988
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning.
    Tian L; Huang Z; Janssens G; Landry G; Dedes G; Kamp F; Belka C; Pinto M; Parodi K
    Phys Med Biol; 2021 Feb; 66(5):055005. PubMed ID: 33171445
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters.
    Cambraia Lopes P; Clementel E; Crespo P; Henrotin S; Huizenga J; Janssens G; Parodi K; Prieels D; Roellinghoff F; Smeets J; Stichelbaut F; Schaart DR
    Phys Med Biol; 2015 Aug; 60(15):6063-85. PubMed ID: 26216269
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of prompt gamma-ray spectroscopy for proton range verification in tissue-mimicking and porcine samples.
    Tattenberg S; Marants R; Niepel K; Bortfeld T; Sudhyadhom A; Landry G; Parodi K; Verburg J
    Phys Med Biol; 2022 Oct; 67(20):. PubMed ID: 36162404
    [No Abstract]   [Full Text] [Related]  

  • 11. Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study.
    Biegun AK; Seravalli E; Lopes PC; Rinaldi I; Pinto M; Oxley DC; Dendooven P; Verhaegen F; Parodi K; Crespo P; Schaart DR
    Phys Med Biol; 2012 Oct; 57(20):6429-44. PubMed ID: 22996154
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning.
    Jiang Z; Polf JC; Barajas CA; Gobbert MK; Ren L
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848674
    [No Abstract]   [Full Text] [Related]  

  • 13. Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy.
    Hueso-González F; Fiedler F; Golnik C; Kormoll T; Pausch G; Petzoldt J; Römer KE; Enghardt W
    Front Oncol; 2016; 6():80. PubMed ID: 27148473
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First clinical application of a prompt gamma based in vivo proton range verification system.
    Richter C; Pausch G; Barczyk S; Priegnitz M; Keitz I; Thiele J; Smeets J; Stappen FV; Bombelli L; Fiorini C; Hotoiu L; Perali I; Prieels D; Enghardt W; Baumann M
    Radiother Oncol; 2016 Feb; 118(2):232-7. PubMed ID: 26774764
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy.
    Min CH; Lee HR; Kim CH; Lee SB
    Med Phys; 2012 Apr; 39(4):2100-7. PubMed ID: 22482631
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A time-of-flight-based reconstruction for real-time prompt-gamma imaging in proton therapy.
    Jacquet M; Marcatili S; Gallin-Martel ML; Bouly JL; Boursier Y; Dauvergne D; Dupont M; Gallin-Martel L; Hérault J; Létang JM; Manéval D; Morel C; Muraz JF; Testa É
    Phys Med Biol; 2021 Jun; 66(13):. PubMed ID: 34020438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A New Method to Reconstruct in 3D the Emission Position of the Prompt Gamma Rays following Proton Beam Irradiation.
    Panaino CMV; Mackay RI; Kirkby KJ; Taylor MJ
    Sci Rep; 2019 Dec; 9(1):18820. PubMed ID: 31827167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Machine learning approach for proton range verification using real-time prompt gamma imaging with Compton cameras: addressing the total deposited energy information gap.
    Kazemi Kozani M
    Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38417182
    [No Abstract]   [Full Text] [Related]  

  • 19. A simulation study investigating a Cherenkov material for use with the prompt gamma range verification in proton therapy.
    Lau A; Ahmad S; Chen Y
    J Xray Sci Technol; 2016 May; 24(4):565-82. PubMed ID: 27163377
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Range shift verification in spot scanning proton therapy using gamma electron vertex imaging.
    Kim SH; Jeong JH; Ku Y; Lee SB; Shin D; Lim YK; Kim H; Kim CH
    Med Phys; 2024 Mar; 51(3):1985-1996. PubMed ID: 37722712
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.