These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 32259990)

  • 1. A bridged loop gap resonator (BLGR) for small animal imaging by 1.5 T MRI systems.
    Staat C; Mützel M; Haase A
    Rev Sci Instrum; 2020 Mar; 91(3):033704. PubMed ID: 32259990
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.
    Omidvari N; Topping G; Cabello J; Paul S; Schwaiger M; Ziegler SI
    Phys Med Biol; 2018 May; 63(9):095002. PubMed ID: 29582780
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T.
    Kim KN; Han SD; Seo JH; Heo P; Yoo D; Im GH; Lee JH
    Magn Reson Med Sci; 2017 Jul; 16(3):253-258. PubMed ID: 27725573
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study on the radiofrequency transparency of electrically floating and ground PET inserts in a 3 T clinical MRI system.
    Akram MSH; Obata T; Nishikido F; Yamaya T
    Med Phys; 2022 May; 49(5):2965-2978. PubMed ID: 35271749
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.
    Lee BJ; Watkins RD; Lee KS; Chang CM; Levin CS
    Magn Reson Med; 2019 Feb; 81(2):1434-1446. PubMed ID: 30260501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a 7 T RF coil system for breast imaging.
    Kim J; Santini T; Bae KT; Krishnamurthy N; Zhao Y; Zhao T; Ibrahim TS
    NMR Biomed; 2017 Jan; 30(1):. PubMed ID: 27859861
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental investigation of RF magnetic field homogeneity in a bridged loop-gap resonator.
    Ono M; Suenaga A; Hirata H
    Magn Reson Med; 2002 Feb; 47(2):415-9. PubMed ID: 11810689
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving local SNR of a single-channel 54.6 mT MRI system using additional LC-resonator.
    Zhang Y; Guo Y; Kong X; Zeng P; Yin H; Wu J; He Y; Xu Z
    J Magn Reson; 2022 Jun; 339():107215. PubMed ID: 35421711
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of a RF-resonant set improving locally the B1+ efficiency. Applications for clinical MRI in andrology and urology.
    Koreshin E; Efimtcev A; Gulko A; Popov S; Orlov I; Trufanov G; Zubkov M
    J Magn Reson; 2020 Aug; 317():106774. PubMed ID: 32589584
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ophthalmic magnetic resonance imaging at 7 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses.
    Graessl A; Muhle M; Schwerter M; Rieger J; Oezerdem C; Santoro D; Lysiak D; Winter L; Hezel F; Waiczies S; Guthoff RF; Falke K; Hosten N; Hadlich S; Krueger PC; Langner S; Stachs O; Niendorf T
    Invest Radiol; 2014 May; 49(5):260-70. PubMed ID: 24651662
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design of a novel antisymmetric coil array for parallel transmit cardiac MRI in pigs at 7 T.
    Elabyad IA; Terekhov M; Stefanescu MR; Lohr D; Fischer M; Schreiber LM
    J Magn Reson; 2019 Aug; 305():195-208. PubMed ID: 31306985
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metamaterial inspired wireless coil for clinical breast imaging.
    Puchnin V; Solomakha G; Nikulin A; Magill AW; Andreychenko A; Shchelokova A
    J Magn Reson; 2021 Jan; 322():106877. PubMed ID: 33278812
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intracranial microvascular imaging at 7 T MRI with transceiver RF coils.
    Kang CK; Woo MK; Hong SM; Kim YB; Cho ZH
    Magn Reson Imaging; 2014 Nov; 32(9):1133-8. PubMed ID: 25093629
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Geometry optimization of electrically floating PET inserts for improved RF penetration for a 3 T MRI system.
    Akram MSH; Levin CS; Obata T; Hirumi G; Yamaya T
    Med Phys; 2018 Oct; 45(10):4627-4641. PubMed ID: 30118140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design, Implementation, and Evaluation of a Head and Neck MRI RF Array Integrated with a 511 keV Transmission Source for Attenuation Correction in PET/MR.
    Navarro de Lara LI; Frass-Kriegl R; Renner A; Sieg J; Pichler M; Bogner T; Moser E; Beyer T; Birkfellner W; Figl M; Laistler E
    Sensors (Basel); 2019 Jul; 19(15):. PubMed ID: 31357545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microstrip Transmission Line RF Coil for a PET/MRI Insert.
    Akram MSH; Obata T; Yamaya T
    Magn Reson Med Sci; 2020 May; 19(2):147-153. PubMed ID: 31776297
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.
    Lavdas I; Seton HC; Harrington CR; Wischik CM
    MAGMA; 2011 Dec; 24(6):331-7. PubMed ID: 21814757
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Black body and transverse electromagnetic resonators operating at 340 MHz: volume RF coils for ultra high field MRI.
    Robitaille PM
    J Comput Assist Tomogr; 1999; 23(6):879-90. PubMed ID: 10589562
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.
    Orzada S; Maderwald S; Göricke SL; Parohl N; Ladd SC; Ladd ME; Quick HH
    Med Phys; 2010 May; 37(5):2225-32. PubMed ID: 20527556
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MR-compatibility of a high-resolution small animal PET insert operating inside a 7 T MRI.
    Thiessen JD; Shams E; Stortz G; Schellenberg G; Bishop D; Khan MS; Kozlowski P; Retière F; Sossi V; Thompson CJ; Goertzen AL
    Phys Med Biol; 2016 Nov; 61(22):7934-7956. PubMed ID: 27779126
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.