These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
268 related articles for article (PubMed ID: 32268304)
1. Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction. Kratochwil N; Gundacker S; Lecoq P; Auffray E Phys Med Biol; 2020 Jun; 65(11):115004. PubMed ID: 32268304 [TBL] [Abstract][Full Text] [Related]
2. Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission. Gundacker S; Martinez Turtos R; Kratochwil N; Pots RH; Paganoni M; Lecoq P; Auffray E Phys Med Biol; 2020 Jan; 65(2):025001. PubMed ID: 31851947 [TBL] [Abstract][Full Text] [Related]
3. On timing-optimized SiPMs for Cherenkov detection to boost low cost time-of-flight PET. Gundacker S; Borghi G; Cherry SR; Gola A; Lee D; Merzi S; Penna M; Schulz V; Kwon SI Phys Med Biol; 2023 Aug; 68(16):. PubMed ID: 37467766 [No Abstract] [Full Text] [Related]
4. BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET. Brunner SE; Schaart DR Phys Med Biol; 2017 Jun; 62(11):4421-4439. PubMed ID: 28358722 [TBL] [Abstract][Full Text] [Related]
5. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction. Yi M; Ko GB; Lee JS Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38091614 [No Abstract] [Full Text] [Related]
6. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET. Kwon SI; Gola A; Ferri A; Piemonte C; Cherry SR Phys Med Biol; 2016 Sep; 61(18):L38-L47. PubMed ID: 27589153 [TBL] [Abstract][Full Text] [Related]
7. High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET. Gundacker S; Turtos RM; Auffray E; Paganoni M; Lecoq P Phys Med Biol; 2019 Feb; 64(5):055012. PubMed ID: 30630146 [TBL] [Abstract][Full Text] [Related]
8. Electronics method to advance the coincidence time resolution with bismuth germanate. Cates JW; Levin CS Phys Med Biol; 2019 Sep; 64(17):175016. PubMed ID: 31300623 [TBL] [Abstract][Full Text] [Related]
9. Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET. Cates JW; Choong WS; Brubaker E Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38252971 [No Abstract] [Full Text] [Related]
10. Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET. Cates JW; Choong WS Phys Med Biol; 2022 Sep; 67(19):. PubMed ID: 35961297 [TBL] [Abstract][Full Text] [Related]
11. Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors. Lee D; Cherry SR; Kwon SI Phys Med Biol; 2023 Sep; 68(18):. PubMed ID: 37579768 [TBL] [Abstract][Full Text] [Related]
12. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout. Seo M; Park H; Lee S; Ko GB; Lee JS Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664 [TBL] [Abstract][Full Text] [Related]
13. A PET detector prototype based on digital SiPMs and GAGG scintillators. Schneider FR; Shimazoe K; Somlai-Schweiger I; Ziegler SI Phys Med Biol; 2015 Feb; 60(4):1667-79. PubMed ID: 25633017 [TBL] [Abstract][Full Text] [Related]
14. Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET. Piller M; Castilla AM; Terragni G; Alozy J; Auffray E; Ballabriga R; Campbell M; Deutschmann B; Gascon D; Gola A; Merzi S; Michalowska-Forsyth A; Penna M; Gómez S; Kratochwil N Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38657637 [No Abstract] [Full Text] [Related]
15. Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET. Gundacker S; Auffray E; Pauwels K; Lecoq P Phys Med Biol; 2016 Apr; 61(7):2802-37. PubMed ID: 26982798 [TBL] [Abstract][Full Text] [Related]
16. Timing advances of commercial divalent-ion co-doped LYSO:Ce and SiPMs in sub-100 ps time-of-flight positron emission tomography. Nadig V; Herweg K; Chou MMC; Lin JWC; Chin E; Li CA; Schulz V; Gundacker S Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36808914 [No Abstract] [Full Text] [Related]
17. SiPM signal readout for inter-crystal scatter event identification in PET detectors. Park H; Lee JS Phys Med Biol; 2020 Oct; 65(20):205010. PubMed ID: 32702670 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution. Cates JW; Levin CS Phys Med Biol; 2018 Jun; 63(11):115011. PubMed ID: 29762136 [TBL] [Abstract][Full Text] [Related]
19. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept. Zhang Y; Yan H; Baghaei H; Wong WH Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144 [TBL] [Abstract][Full Text] [Related]
20. A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET. Kratochwil N; Gundacker S; Auffray E Phys Med Biol; 2021 Sep; 66(19):. PubMed ID: 34433139 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]