250 related articles for article (PubMed ID: 32272251)
1. Diagnostic Performance of Vibration-Controlled Transient Elastography in Liver Transplant Recipients.
Siddiqui MS; Idowu MO; Stromberg K; Sima A; Lee E; Patel S; Ghaus S; Driscoll C; Sterling RK; John B; Bhati CS
Clin Gastroenterol Hepatol; 2021 Feb; 19(2):367-374. PubMed ID: 32272251
[TBL] [Abstract][Full Text] [Related]
2. Vibration-Controlled Transient Elastography to Assess Fibrosis and Steatosis in Patients With Nonalcoholic Fatty Liver Disease.
Siddiqui MS; Vuppalanchi R; Van Natta ML; Hallinan E; Kowdley KV; Abdelmalek M; Neuschwander-Tetri BA; Loomba R; Dasarathy S; Brandman D; Doo E; Tonascia JA; Kleiner DE; Chalasani N; Sanyal AJ;
Clin Gastroenterol Hepatol; 2019 Jan; 17(1):156-163.e2. PubMed ID: 29705261
[TBL] [Abstract][Full Text] [Related]
3. Accuracy of FibroScan Controlled Attenuation Parameter and Liver Stiffness Measurement in Assessing Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.
Eddowes PJ; Sasso M; Allison M; Tsochatzis E; Anstee QM; Sheridan D; Guha IN; Cobbold JF; Deeks JJ; Paradis V; Bedossa P; Newsome PN
Gastroenterology; 2019 May; 156(6):1717-1730. PubMed ID: 30689971
[TBL] [Abstract][Full Text] [Related]
4. Magnetic Resonance Elastography vs Transient Elastography in Detection of Fibrosis and Noninvasive Measurement of Steatosis in Patients With Biopsy-Proven Nonalcoholic Fatty Liver Disease.
Park CC; Nguyen P; Hernandez C; Bettencourt R; Ramirez K; Fortney L; Hooker J; Sy E; Savides MT; Alquiraish MH; Valasek MA; Rizo E; Richards L; Brenner D; Sirlin CB; Loomba R
Gastroenterology; 2017 Feb; 152(3):598-607.e2. PubMed ID: 27911262
[TBL] [Abstract][Full Text] [Related]
5. Development of Clinical Algorithm Utilizing Vibration-Controlled Transient Elastography to Detect Advanced Hepatic Fibrosis in Liver Transplant Recipients.
Arshad T; Vainer D; Khan H; Baral A; Garg S; Ang A; Patel V; Kumaran V; Bruno D; Lee S; Sharma A; Muthiah M; Bui AT; Siddiqui MS
Dig Dis Sci; 2024 May; 69(5):1844-1851. PubMed ID: 38499735
[TBL] [Abstract][Full Text] [Related]
6. Application of the combined FibroMeter vibration-controlled transient elastography algorithm in Chinese patients with non-alcoholic fatty liver disease.
Loong TC; Wei JL; Leung JC; Wong GL; Shu SS; Chim AM; Chan AW; Choi PC; Tse YK; Chan HL; Wong VW
J Gastroenterol Hepatol; 2017 Jul; 32(7):1363-1369. PubMed ID: 27936280
[TBL] [Abstract][Full Text] [Related]
7. The Performance of Vibration Controlled Transient Elastography in a US Cohort of Patients With Nonalcoholic Fatty Liver Disease.
Tapper EB; Challies T; Nasser I; Afdhal NH; Lai M
Am J Gastroenterol; 2016 May; 111(5):677-84. PubMed ID: 26977758
[TBL] [Abstract][Full Text] [Related]
8. Diagnostic accuracy of combined biomarker measurements and vibration-controlled transient elastography (VCTE) for predicting fibrosis stage of non-alcoholic fatty liver disease.
Shima T; Sakai K; Oya H; Katayama T; Mitsumoto Y; Mizuno M; Kanbara Y; Okanoue T
J Gastroenterol; 2020 Jan; 55(1):100-112. PubMed ID: 31538241
[TBL] [Abstract][Full Text] [Related]
9. Assessment of transient elastography in diagnosing MAFLD and the early effects of sleeve gastrectomy on MAFLD among the Chinese population.
Hu R; Wu B; Wang C; Wu Z; Zhang X; Chen X; Lu G; Yuan K
Int J Surg; 2024 Apr; 110(4):2044-2054. PubMed ID: 38215263
[TBL] [Abstract][Full Text] [Related]
10. Detection of graft fibrosis by vibration-controlled transient elastography in pediatric liver transplant recipients.
Costa P; Kogan-Liberman D; Rudolph B; Silver E; Ewart M; Raizner A; Cunningham R; Ovchinsky N
Pediatr Transplant; 2020 Sep; 24(6):e13731. PubMed ID: 32427407
[TBL] [Abstract][Full Text] [Related]
11. Diagnostic Performance of FibroTouch Ultrasound Attenuation Parameter and Liver Stiffness Measurement in Assessing Hepatic Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.
Qu Y; Song YY; Chen CW; Fu QC; Shi JP; Xu Y; Xie Q; Yang YF; Zhou YJ; Li LP; Xu MY; Cai XB; Zhang QD; Yu H; Fan JG; Lu LG
Clin Transl Gastroenterol; 2021 Apr; 12(4):e00323. PubMed ID: 33848277
[TBL] [Abstract][Full Text] [Related]
12. Controlled Attenuation Parameter (CAP): a noninvasive method for the detection of hepatic steatosis based on transient elastography.
Myers RP; Pollett A; Kirsch R; Pomier-Layrargues G; Beaton M; Levstik M; Duarte-Rojo A; Wong D; Crotty P; Elkashab M
Liver Int; 2012 Jul; 32(6):902-10. PubMed ID: 22435761
[TBL] [Abstract][Full Text] [Related]
13. Prediction of Liver-Related Events With a Combination of Liver Stiffness Measurements and Controlled Attenuation Parameters in Japanese Patients With Biopsy-Proven Non-alcoholic Fatty Liver Disease.
Hayashi H; Kamada Y; Fujii H; Takahashi H; Oeda S; Iwaki M; Kawaguchi T; Tomita E; Yoneda M; Tokushige A; Ueda S; Aishima S; Sumida Y; Nakajima A; Okanoue T;
Ultrasound Med Biol; 2023 Jul; 49(7):1658-1664. PubMed ID: 37120329
[TBL] [Abstract][Full Text] [Related]
14. Magnetic Resonance Imaging More Accurately Classifies Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease Than Transient Elastography.
Imajo K; Kessoku T; Honda Y; Tomeno W; Ogawa Y; Mawatari H; Fujita K; Yoneda M; Taguri M; Hyogo H; Sumida Y; Ono M; Eguchi Y; Inoue T; Yamanaka T; Wada K; Saito S; Nakajima A
Gastroenterology; 2016 Mar; 150(3):626-637.e7. PubMed ID: 26677985
[TBL] [Abstract][Full Text] [Related]
15. Utility of transient elastography (fibroscan) and impact of bariatric surgery on nonalcoholic fatty liver disease (NAFLD) in morbidly obese patients.
Garg H; Aggarwal S; Shalimar ; Yadav R; Datta Gupta S; Agarwal L; Agarwal S
Surg Obes Relat Dis; 2018 Jan; 14(1):81-91. PubMed ID: 29126863
[TBL] [Abstract][Full Text] [Related]
16. Evaluation and comparison of six noninvasive tests for prediction of significant or advanced fibrosis in nonalcoholic fatty liver disease.
Staufer K; Halilbasic E; Spindelboeck W; Eilenberg M; Prager G; Stadlbauer V; Posch A; Munda P; Marculescu R; Obermayer-Pietsch B; Stift J; Lackner C; Trauner M; Stauber RE
United European Gastroenterol J; 2019 Oct; 7(8):1113-1123. PubMed ID: 31662868
[TBL] [Abstract][Full Text] [Related]
17. Vibration Controlled Transient Elastography to Evaluate Steatosis in Candidate Living Donors for Liver Transplantation.
Palte E; Duong JK; Remotti H; Burt J; Makkar J; Samstein B; Verna EC; Marratta D; Emond JC; Fox AN
Transplantation; 2023 Sep; 107(9):1991-1998. PubMed ID: 36959124
[TBL] [Abstract][Full Text] [Related]
18. Usefulness of Controlled Attenuation Parameter and Liver Stiffness Measurement for the Identification of Extended-criteria Donors and Risk-assessment in Liver Transplantation.
Duarte-Rojo A; Heimbach JK; Borja-Cacho D; Barone GW; Shaheen MF; Lamps LW; Graham RP; Tan EK; Concepcion W; Kim WR
Transplantation; 2022 Feb; 106(2):318-327. PubMed ID: 33675319
[TBL] [Abstract][Full Text] [Related]
19. Unified interpretation of liver stiffness measurement by M and XL probes in non-alcoholic fatty liver disease.
Wong VW; Irles M; Wong GL; Shili S; Chan AW; Merrouche W; Shu SS; Foucher J; Le Bail B; Chan WK; Chan HL; de Ledinghen V
Gut; 2019 Nov; 68(11):2057-2064. PubMed ID: 30658997
[TBL] [Abstract][Full Text] [Related]
20. Diagnostic accuracy of non-invasive tests for advanced fibrosis in patients with NAFLD: an individual patient data meta-analysis.
Mózes FE; Lee JA; Selvaraj EA; Jayaswal ANA; Trauner M; Boursier J; Fournier C; Staufer K; Stauber RE; Bugianesi E; Younes R; Gaia S; Lupșor-Platon M; Petta S; Shima T; Okanoue T; Mahadeva S; Chan WK; Eddowes PJ; Hirschfield GM; Newsome PN; Wong VW; de Ledinghen V; Fan J; Shen F; Cobbold JF; Sumida Y; Okajima A; Schattenberg JM; Labenz C; Kim W; Lee MS; Wiegand J; Karlas T; Yılmaz Y; Aithal GP; Palaniyappan N; Cassinotto C; Aggarwal S; Garg H; Ooi GJ; Nakajima A; Yoneda M; Ziol M; Barget N; Geier A; Tuthill T; Brosnan MJ; Anstee QM; Neubauer S; Harrison SA; Bossuyt PM; Pavlides M;
Gut; 2022 May; 71(5):1006-1019. PubMed ID: 34001645
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]