164 related articles for article (PubMed ID: 32274646)
1. Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study.
Seet E; Zhang J; Macachor J; Kumar CM
J Clin Monit Comput; 2021 May; 35(3):443-447. PubMed ID: 32274646
[TBL] [Abstract][Full Text] [Related]
2. Comparison of i-gel, LMA-supreme, LMA-classic and LMAproseal as conduits of endotracheal intubation in newborns and infants: A manikin study.
Ankay-Yılbaş A; Başaran B; Üzümcügil F; Akça B; İzgi M; Canbay Ö
Turk J Pediatr; 2019; 61(2):166-173. PubMed ID: 32077644
[TBL] [Abstract][Full Text] [Related]
3. Tracheal intubation via the Classic and Proseal laryngeal mask airways: a manikin study using the Aintree Intubating Catheter.
Blair EJ; Mihai R; Cook TM
Anaesthesia; 2007 Apr; 62(4):385-7. PubMed ID: 17381576
[TBL] [Abstract][Full Text] [Related]
4. Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices.
Schmutz A; Bohn E; Spaeth J; Heinrich S
Ther Clin Risk Manag; 2019; 15():367-376. PubMed ID: 30881002
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the Ambu AuraFlex with the laryngeal mask airway Flexible: a manikin study.
Sanuki T; Nakatani G; Sugioka S; Daigo E; Kotani J
J Oral Maxillofac Surg; 2011 Jul; 69(7):e269-72. PubMed ID: 21549471
[TBL] [Abstract][Full Text] [Related]
6. Dimensional compatibility and limitations of tracheal intubation through supraglottic airway devices: a mannequin-based in vitro study.
Moser B; Kemper M; Kleine-Brueggeney M; Gasteiger L; Weiss M
Can J Anaesth; 2021 Sep; 68(9):1337-1348. PubMed ID: 34018159
[TBL] [Abstract][Full Text] [Related]
7. Comparison of three supraglottic airway devices for blind tracheal intubation by novice practitioners: A randomized manikin study.
Sonmez O; Colak N; Bayram B; Kara SG; Halac SS
Turk J Emerg Med; 2024; 24(2):97-102. PubMed ID: 38766418
[TBL] [Abstract][Full Text] [Related]
8. Pediatric supraglottic airway devices in clinical practice: A prospective observational study.
Kleine-Brueggeney M; Gottfried A; Nabecker S; Greif R; Book M; Theiler L
BMC Anesthesiol; 2017 Sep; 17(1):119. PubMed ID: 28865448
[TBL] [Abstract][Full Text] [Related]
9. Similar oropharyngeal leak pressures during anaesthesia with i-gel, LMA-ProSeal and LMA-Supreme Laryngeal Masks.
Van Zundert TC; Brimacombe JR
Acta Anaesthesiol Belg; 2012; 63(1):35-41. PubMed ID: 22783708
[TBL] [Abstract][Full Text] [Related]
10. A randomized comparison of the Ambu AuraGain versus the LMA supreme in patients undergoing gynaecologic laparoscopic surgery.
Lopez AM; Agusti M; Gambus P; Pons M; Anglada T; Valero R
J Clin Monit Comput; 2017 Dec; 31(6):1255-1262. PubMed ID: 27889843
[TBL] [Abstract][Full Text] [Related]
11. Intraocular pressure and haemodynamic responses to insertion of the i-gel, laryngeal mask airway or endotracheal tube.
Ismail SA; Bisher NA; Kandil HW; Mowafi HA; Atawia HA
Eur J Anaesthesiol; 2011 Jun; 28(6):443-8. PubMed ID: 21455075
[TBL] [Abstract][Full Text] [Related]
12. Comparison of Gastric Insufflation Volume Between Ambu AuraGain and ProSeal Laryngeal Mask Airway Using Ultrasonography in Patients Undergoing General Anesthesia: A Randomized Controlled Trial.
Gunasekaran A; Govindaraj K; Gupta SL; Vinayagam S; Mishra SK
Cureus; 2022 Aug; 14(8):e27888. PubMed ID: 36110490
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.
Jackson KM; Cook TM
Anaesthesia; 2007 Apr; 62(4):388-93. PubMed ID: 17381577
[TBL] [Abstract][Full Text] [Related]
14. Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial.
Seet E; Rajeev S; Firoz T; Yousaf F; Wong J; Wong DT; Chung F
Eur J Anaesthesiol; 2010 Jul; 27(7):602-7. PubMed ID: 20540172
[TBL] [Abstract][Full Text] [Related]
15. [Manikin-based comparison of the use of different supraglottic airways by laypersons].
Jänig C; Balogh O; Krappitz S; Willms A; Schmidbauer W; Piepho T
Med Klin Intensivmed Notfmed; 2022 Jun; 117(5):374-380. PubMed ID: 34125259
[TBL] [Abstract][Full Text] [Related]
16. A comparison of the disposable Ambu AuraOnce Laryngeal Mask with the reusable LMA Classic laryngeal mask airway.
Sudhir G; Redfern D; Hall JE; Wilkes AR; Cann C
Anaesthesia; 2007 Jul; 62(7):719-22. PubMed ID: 17567349
[TBL] [Abstract][Full Text] [Related]
17. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?
Tracy MB; Priyadarshi A; Goel D; Lowe K; Huvanandana J; Hinder M
Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F271-F276. PubMed ID: 28802261
[TBL] [Abstract][Full Text] [Related]
18. Sore throat following three adult supraglottic airway devices: A randomised controlled trial.
L'Hermite J; Dubout E; Bouvet S; Bracoud LH; Cuvillon P; Coussaye JE; Ripart J
Eur J Anaesthesiol; 2017 Jul; 34(7):417-424. PubMed ID: 27755181
[TBL] [Abstract][Full Text] [Related]
19. Laryngeal mask airway ProSeal provides higher oropharyngeal leak pressure than i-gel in adult patients under general anesthesia: a meta-analysis.
Maitra S; Baidya DK; Arora MK; Bhattacharjee S; Khanna P
J Clin Anesth; 2016 Sep; 33():298-305. PubMed ID: 27555181
[TBL] [Abstract][Full Text] [Related]
20. The laryngeal mask airway Supreme--a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients.
Eschertzhuber S; Brimacombe J; Hohlrieder M; Keller C
Anaesthesia; 2009 Jan; 64(1):79-83. PubMed ID: 19087011
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]