BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 32275034)

  • 1. Comparison of continuous cardiac output monitoring derived from regional impedance cardiography with continuous thermodilution technique in cardiac surgical patients.
    Bhavya G; Nagaraja PS; Singh NG; Ragavendran S; Sathish N; Manjunath N; Kumar KA; Nayak VB
    Ann Card Anaesth; 2020; 23(2):189-192. PubMed ID: 32275034
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive assessment of Cardiac Index using impedance cardiography during liver transplantation surgery: a comparison with pulmonary artery thermodilution.
    Suparschi V; Le Bihan E; Toussaint A; Saptefrat D; Ben Abdallah H; Gloulou F; Aouati F; Gauss T; Paugam-Burtz C
    Minerva Anestesiol; 2019 Jan; 85(1):28-33. PubMed ID: 29745622
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.
    Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y
    J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor.
    Maus TM; Reber B; Banks DA; Berry A; Guerrero E; Manecke GR
    J Cardiothorac Vasc Anesth; 2011 Oct; 25(5):770-5. PubMed ID: 21354828
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values.
    Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y
    J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.
    Graeser K; Zemtsovski M; Kofoed KF; Winther-Jensen M; Nilsson JC; Kjaergaard J; Møller-Sørensen H
    Anesth Analg; 2018 Aug; 127(2):399-407. PubMed ID: 29324489
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients.
    Møller-Sørensen H; Cordtz J; Østergaard M; Nilsson JC; Hansen KL
    J Clin Monit Comput; 2017 Feb; 31(1):135-142. PubMed ID: 26578096
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study.
    Montenij LJ; Buhre WF; de Jong SA; Harms JH; van Herwaarden JA; Kruitwagen CL; de Waal EE
    Eur J Anaesthesiol; 2015 Jan; 32(1):13-9. PubMed ID: 25303970
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of impedance cardiography for evaluating trends in cardiac output: a comparison with oesophageal Doppler.
    Lorne E; Mahjoub Y; Diouf M; Sleghem J; Buchalet C; Guinot PG; Petiot S; Kessavane A; Dehedin B; Dupont H
    Br J Anaesth; 2014 Oct; 113(4):596-602. PubMed ID: 24871872
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique.
    Maass SW; Roekaerts PM; Lancé MD
    J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output monitoring with pulmonary versus transpulmonary thermodilution during liver transplantation: interchangeable methods?
    Vilchez Monge AL; Tranche Alvarez-Cagigas I; Perez-Peña J; Olmedilla L; Jimeno C; Sanz J; Bellón Cano JM; Garutti I
    Minerva Anestesiol; 2014 Nov; 80(11):1178-87. PubMed ID: 24569356
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes.
    Suehiro K; Tanaka K; Mikawa M; Uchihara Y; Matsuyama T; Matsuura T; Funao T; Yamada T; Mori T; Nishikawa K
    J Cardiothorac Vasc Anesth; 2015; 29(3):656-62. PubMed ID: 25440654
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.
    Smetkin AA; Hussain A; Kuzkov VV; Bjertnæs LJ; Kirov MY
    Br J Anaesth; 2014 Jun; 112(6):1024-31. PubMed ID: 24531685
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.
    Smetkin AA; Hussain A; Fot EV; Zakharov VI; Izotova NN; Yudina AS; Dityateva ZA; Gromova YV; Kuzkov VV; Bjertnæs LJ; Kirov MY
    J Clin Monit Comput; 2017 Apr; 31(2):361-370. PubMed ID: 26951494
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation.
    Magliocca A; Rezoagli E; Anderson TA; Burns SM; Ichinose F; Chitilian HV
    Anesth Analg; 2018 Jan; 126(1):85-92. PubMed ID: 28598912
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.
    Bein B; Worthmann F; Tonner PH; Paris A; Steinfath M; Hedderich J; Scholz J
    J Cardiothorac Vasc Anesth; 2004 Apr; 18(2):185-9. PubMed ID: 15073709
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy, Precision, and Trending Ability of Uncalibrated Arterial Pressure Waveform Analysis of Cardiac Output in Patients With Impaired Left Ventricular Function: A Prospective, Observational Study.
    Montenij LJ; Sonneveld JP; Nierich AP; Buhre WF; De Waal EE
    J Cardiothorac Vasc Anesth; 2016 Jan; 30(1):115-21. PubMed ID: 26520028
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of cardiac output measurement by regional impedance cardiography and thermodilution method in patients undergoing off pump coronary artery bypass graft surgery.
    Guha A; Arora D; Mehta Y
    Ann Card Anaesth; 2022; 25(3):335-342. PubMed ID: 35799563
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The influence of acute pulmonary hypertension on cardiac output measurements: calibrated pulse contour analysis, transpulmonary and pulmonary artery thermodilution against a modified Fick method in an animal model.
    Kutter APN; Mosing M; Hartnack S; Raszplewicz J; Renggli M; Mauch JY; Hofer CK
    Anesth Analg; 2015 Jul; 121(1):99-107. PubMed ID: 25742632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.