363 related articles for article (PubMed ID: 32277703)
1. Multicenter evaluation of MRI-based radiomic features: A phantom study.
Rai R; Holloway LC; Brink C; Field M; Christiansen RL; Sun Y; Barton MB; Liney GP
Med Phys; 2020 Jul; 47(7):3054-3063. PubMed ID: 32277703
[TBL] [Abstract][Full Text] [Related]
2. Technical Note: Virtual phantom analyses for preprocessing evaluation and detection of a robust feature set for MRI-radiomics of the brain.
Bologna M; Corino V; Mainardi L
Med Phys; 2019 Nov; 46(11):5116-5123. PubMed ID: 31539450
[TBL] [Abstract][Full Text] [Related]
3. Physics-Informed Discretization for Reproducible and Robust Radiomic Feature Extraction Using Quantitative MRI.
Zhao W; Hu Z; Kazerooni AF; Körzdörfer G; Nittka M; Davatzikos C; Viswanath SE; Wang X; Badve C; Ma D
Invest Radiol; 2024 May; 59(5):359-371. PubMed ID: 37812483
[TBL] [Abstract][Full Text] [Related]
4. Longitudinal acquisition repeatability of MRI radiomics features: An ACR MRI phantom study on two MRI scanners using a 3D T1W TSE sequence.
Wong OL; Yuan J; Zhou Y; Yu SK; Cheung KY
Med Phys; 2021 Mar; 48(3):1239-1249. PubMed ID: 33370474
[TBL] [Abstract][Full Text] [Related]
5. A multicenter study on radiomic features from T
Bianchini L; Santinha J; Loução N; Figueiredo M; Botta F; Origgi D; Cremonesi M; Cassano E; Papanikolaou N; Lascialfari A
Magn Reson Med; 2021 Mar; 85(3):1713-1726. PubMed ID: 32970859
[TBL] [Abstract][Full Text] [Related]
6. Identification of reproducible radiomic features from on-board volumetric images: A multi-institutional phantom study.
Adachi T; Nakamura M; Iramina H; Matsumoto K; Ishihara Y; Tachibana H; Kurokawa S; Cho S; Tanaka K; Fukumoto K; Nishiyama T; Kito S; Mizowaki T
Med Phys; 2023 Sep; 50(9):5585-5596. PubMed ID: 36932977
[TBL] [Abstract][Full Text] [Related]
7. Identification of robust and reproducible CT-texture metrics using a customized 3D-printed texture phantom.
Varghese BA; Hwang D; Cen SY; Lei X; Levy J; Desai B; Goodenough DJ; Duddalwar VA
J Appl Clin Med Phys; 2021 Feb; 22(2):98-107. PubMed ID: 33434374
[TBL] [Abstract][Full Text] [Related]
8. The impact of phantom design and material-dependence on repeatability and reproducibility of CT-based radiomics features.
Li Y; Reyhan M; Zhang Y; Wang X; Zhou J; Zhang Y; Yue NJ; Nie K
Med Phys; 2022 Mar; 49(3):1648-1659. PubMed ID: 35103332
[TBL] [Abstract][Full Text] [Related]
9. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels.
Shafiq-Ul-Hassan M; Zhang GG; Latifi K; Ullah G; Hunt DC; Balagurunathan Y; Abdalah MA; Schabath MB; Goldgof DG; Mackin D; Court LE; Gillies RJ; Moros EG
Med Phys; 2017 Mar; 44(3):1050-1062. PubMed ID: 28112418
[TBL] [Abstract][Full Text] [Related]
10. The impact of image reconstruction settings on 18F-FDG PET radiomic features: multi-scanner phantom and patient studies.
Shiri I; Rahmim A; Ghaffarian P; Geramifar P; Abdollahi H; Bitarafan-Rajabi A
Eur Radiol; 2017 Nov; 27(11):4498-4509. PubMed ID: 28567548
[TBL] [Abstract][Full Text] [Related]
11. Phantom study investigating the repeatability of radiomic features with alteration of image acquisition parameters in magnetic resonance imaging.
Mitchell-Hay R; Ahearn T; Murray A; Waiter G
J Med Imaging Radiat Sci; 2024 Mar; 55(1):19-28. PubMed ID: 37932212
[TBL] [Abstract][Full Text] [Related]
12. Influence of Image Processing on Radiomic Features From Magnetic Resonance Imaging.
Wichtmann BD; Harder FN; Weiss K; Schönberg SO; Attenberger UI; Alkadhi H; Pinto Dos Santos D; Baeßler B
Invest Radiol; 2023 Mar; 58(3):199-208. PubMed ID: 36070524
[TBL] [Abstract][Full Text] [Related]
13. Impact of harmonization on the reproducibility of MRI radiomic features when using different scanners, acquisition parameters, and image pre-processing techniques: a phantom study.
Hajianfar G; Hosseini SA; Bagherieh S; Oveisi M; Shiri I; Zaidi H
Med Biol Eng Comput; 2024 Mar; ():. PubMed ID: 38536580
[TBL] [Abstract][Full Text] [Related]
14. PETER PHAN: An MRI phantom for the optimisation of radiomic studies of the female pelvis.
Bianchini L; Botta F; Origgi D; Rizzo S; Mariani M; Summers P; García-Polo P; Cremonesi M; Lascialfari A
Phys Med; 2020 Mar; 71():71-81. PubMed ID: 32092688
[TBL] [Abstract][Full Text] [Related]
15. Repeatability and reproducibility of MRI-radiomic features: A phantom experiment on a 1.5 T scanner.
Bologna M; Tenconi C; Corino VDA; Annunziata G; Orlandi E; Calareso G; Pignoli E; Valdagni R; Mainardi LT; Rancati T
Med Phys; 2023 Feb; 50(2):750-762. PubMed ID: 36310346
[TBL] [Abstract][Full Text] [Related]
16. Repeatability of
Pfaehler E; Beukinga RJ; de Jong JR; Slart RHJA; Slump CH; Dierckx RAJO; Boellaard R
Med Phys; 2019 Feb; 46(2):665-678. PubMed ID: 30506687
[TBL] [Abstract][Full Text] [Related]
17. Three-dimensional printing of MRI-visible phantoms and MR image-guided therapy simulation.
Mitsouras D; Lee TC; Liacouras P; Ionita CN; Pietilla T; Maier SE; Mulkern RV
Magn Reson Med; 2017 Feb; 77(2):613-622. PubMed ID: 26864335
[TBL] [Abstract][Full Text] [Related]
18. A radiomics pipeline dedicated to Breast MRI: validation on a multi-scanner phantom study.
Saint Martin MJ; Orlhac F; Akl P; Khalid F; Nioche C; Buvat I; Malhaire C; Frouin F
MAGMA; 2021 Jun; 34(3):355-366. PubMed ID: 33180226
[TBL] [Abstract][Full Text] [Related]
19. Statistical Analysis on Impact of Image Preprocessing of CT Texture Patterns and Its CT Radiomic Feature Stability: A Phantom Study.
Palani D; Ganesh KM; Karunagaran L; Govindaraj K; Shanmugam S
Asian Pac J Cancer Prev; 2023 Jun; 24(6):2061-2072. PubMed ID: 37378937
[TBL] [Abstract][Full Text] [Related]
20. Repeatability and reproducibility of MRI-based radiomic features in cervical cancer.
Fiset S; Welch ML; Weiss J; Pintilie M; Conway JL; Milosevic M; Fyles A; Traverso A; Jaffray D; Metser U; Xie J; Han K
Radiother Oncol; 2019 Jun; 135():107-114. PubMed ID: 31015155
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]