120 related articles for article (PubMed ID: 322893)
1. Adaptation of the EMIT serum digoxin assay to a mini-disc centrifugal analyzer.
Brunk SD; Malmstadt HV
Clin Chem; 1977 Jun; 23(6):1054-6. PubMed ID: 322893
[TBL] [Abstract][Full Text] [Related]
2. Adaptation of the Syva EMIT-cad digoxin enzyme immunoassay technique on the Instrumentation Laboratory Multistat-III microcentrifugal analyzer.
Alain J; Forest JC
Ther Drug Monit; 1984; 6(4):489-92. PubMed ID: 6393465
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of EMIT adapted to the (Cobas) Bio centrifugal analyzer.
Oellerich M; Haeckel R; Haindl H
J Clin Chem Clin Biochem; 1982 Oct; 20(10):765-72. PubMed ID: 6754852
[TBL] [Abstract][Full Text] [Related]
4. Homogeneous enzyme immunoassay of serum digoxin with use of a bichromatic analyzer.
Eriksen PB; Andersen O
Clin Chem; 1979 Jan; 25(1):169-71. PubMed ID: 367634
[TBL] [Abstract][Full Text] [Related]
5. Fully automated protocol for EMIT determination of serum digoxin with the Cobas FARA centrifugal analyzer.
Vinet B
Clin Chem; 1986 Aug; 32(8):1592-3. PubMed ID: 3524904
[No Abstract] [Full Text] [Related]
6. Evaluation of the EMIT reagent system for measurement of caffeine with the EMIT Lab 5000 System and a centrifugal analyzer.
Ou CN; Frawley VL; Ellis JM
Clin Chem; 1984 Jun; 30(6):887-9. PubMed ID: 6373054
[TBL] [Abstract][Full Text] [Related]
7. Assay of phenobarbital: adaption of "EMIT" to the centrifugal analyzer.
Finley PR; Willaims RJ; Lichti DF; Byers JM
Clin Chem; 1977; 23(4):738-40. PubMed ID: 321148
[TBL] [Abstract][Full Text] [Related]
8. Improved sensitivity of digoxin assay by modification of the EMIT 2000 method.
Radembino N; Poirier JM; Ragueneau I; Jaillon P
Ther Drug Monit; 1999 Apr; 21(2):256-8. PubMed ID: 10217349
[TBL] [Abstract][Full Text] [Related]
9. [Adaptation of the immunoenzyme assay of digoxin to the GEMSAEC centrifugal analyzer].
Boyer JF; Heurté PY; Libert JM; Vierfond JM
Ann Biol Clin (Paris); 1982; 40(4):325-7. PubMed ID: 6756219
[No Abstract] [Full Text] [Related]
10. A comparative study of the homogeneous enzyme immunoassay (EMIT) and two radioimmunoassays (RIA's) for digoxin.
Drost RH; Plomp TA; Teunissen AJ; Maes AH; Maes RA
Clin Chim Acta; 1977 Sep; 79(3):557-67. PubMed ID: 330027
[TBL] [Abstract][Full Text] [Related]
11. Cross reactivity of the EMIT digoxin assay with digoxin metabolites, and validation of the method for measurement of urinary digoxin.
Linday L; Drayer DE
Clin Chem; 1983 Jan; 29(1):175-7. PubMed ID: 6336678
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.
Rosenthal AF; Vargas MG; Klass CS
Clin Chem; 1976 Nov; 22(11):1899-902. PubMed ID: 184987
[TBL] [Abstract][Full Text] [Related]
13. Immunoassay of digoxin by differential centrifugation.
Lentrichia BB; Sciotto-Brown SJ; Turanchik MF; Ropiak IK; Yeung KK
Clin Chem; 1987 Sep; 33(9):1548-53. PubMed ID: 3621555
[TBL] [Abstract][Full Text] [Related]
14. An automated, affinity-column-mediated, enzyme-linked immunometric assay for digoxin on the Du Pont aca discrete clinical analyzer.
Leflar CC; Freytag JW; Powell LM; Strahan JC; Wadsley JJ; Tyler CA; Miller WK
Clin Chem; 1984 Nov; 30(11):1809-11. PubMed ID: 6207957
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of five immunoassays for the determination of digoxin in serum.
Sasieta M; Jimeno P
Eur J Clin Chem Clin Biochem; 1996 Nov; 34(11):935-40. PubMed ID: 8960471
[TBL] [Abstract][Full Text] [Related]
16. Homogeneous enzyme immunoassay for theophylline with a centrifugal analyzer.
Lacher DA; Sinn JA; Savory J; Wills MR
Ann Clin Lab Sci; 1980; 10(4):305-10. PubMed ID: 7004330
[TBL] [Abstract][Full Text] [Related]
17. Comparison of digoxin analysis by EMIT with Immophase and Dac-Cel radioimmunoassay.
Rumley AG; Trope A; Rowe DJ; Hainsworth IR
Ann Clin Biochem; 1980 Nov; 17(6):315-8. PubMed ID: 7011165
[TBL] [Abstract][Full Text] [Related]
18. [A system for the mechanized radioimmunological determination of digoxin].
Dwenger A; Friedel R
Fortschr Med; 1978 May; 96(18):989-96. PubMed ID: 649005
[TBL] [Abstract][Full Text] [Related]
19. Centrifugal analyzer used for enzyme immunoassay of progesterone and choriomammotropin.
Terouanne B; Marchand J; Calzolari C; Monnier J; Nicolas JC; Pau B; Descomps B
Clin Chem; 1983 Feb; 29(2):302-4. PubMed ID: 6336995
[TBL] [Abstract][Full Text] [Related]
20. An improved theophylline method by EMIT on the multistat III micro centrifugal analyzer.
Massey TH; Barta JS
Ther Drug Monit; 1982; 4(4):413-8. PubMed ID: 6760475
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]