These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 32311693)

  • 21. Characteristics of the Exradin W1 scintillator in the magnetic field.
    Yoon J; Kim JI; Choi CH; Park JM
    J Appl Clin Med Phys; 2019 Sep; 20(9):149-156. PubMed ID: 31460702
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.
    Malkov VN; Rogers DWO
    Med Phys; 2018 Feb; 45(2):908-925. PubMed ID: 29218730
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Radioluminescence of some optical fibres.
    Nowotny R
    Phys Med Biol; 2007 Feb; 52(4):N67-73. PubMed ID: 17264357
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Scintillation properties of the YVO4:Eu3+ compound in powder form: its application to dosimetry in radiation fields produced by pulsed mega-voltage photon beams.
    Martinez N; Teichmann T; Molina P; Sommer M; Santiago M; Henniger J; Caselli E
    Z Med Phys; 2015 Dec; 25(4):368-374. PubMed ID: 25957990
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Simultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry.
    Yoo WJ; Shin SH; Jeon D; Hong S; Kim SG; Sim HI; Jang KW; Cho S; Lee B
    Opt Express; 2013 Nov; 21(23):27770-9. PubMed ID: 24514292
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator.
    Le Deroff C; Frelin AM; Ledoux X
    Phys Med Biol; 2019 May; 64(11):115015. PubMed ID: 30974415
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.
    Bourgouin A; Varfalvy N; Archambault L
    J Appl Clin Med Phys; 2016 Sep; 17(5):542-547. PubMed ID: 27685131
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Water-equivalent one-dimensional scintillating fiber-optic dosimeter for measuring therapeutic photon beam.
    Moon J; Jang KW; Yoo WJ; Han KT; Park JY; Lee B
    Appl Radiat Isot; 2012 Nov; 70(11):2627-30. PubMed ID: 22944534
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.
    Alagar AG; Mani GK; Karunakaran K
    J Appl Clin Med Phys; 2016 Jan; 17(1):132-142. PubMed ID: 26894345
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Temperature dependence of BCF plastic scintillation detectors.
    Wootton L; Beddar S
    Phys Med Biol; 2013 May; 58(9):2955-67. PubMed ID: 23574889
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The visible signal responsible for proton therapy dosimetry using bare optical fibers is not Čerenkov radiation.
    Darafsheh A; Taleei R; Kassaee A; Finlay JC
    Med Phys; 2016 Nov; 43(11):5973. PubMed ID: 27806617
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Technical Note: Angular dependence of a 2D monolithic silicon diode array for small field dosimetry.
    Stansook N; Utitsarn K; Petasecca M; Newall MK; Duncan M; Nitschke K; Carolan M; Metcalfe P; Lerch MLF; Perevertaylo VL; Tomé WA; Rosenfeld AB
    Med Phys; 2017 Aug; 44(8):4313-4321. PubMed ID: 28556261
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Response of plastic scintillators to low-energy photons.
    Peralta L; Rêgo F
    Phys Med Biol; 2014 Aug; 59(16):4621-33. PubMed ID: 25079252
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Application of the Exradin W1 scintillator to determine Ediode 60017 and microDiamond 60019 correction factors for relative dosimetry within small MV and FFF fields.
    Underwood TS; Rowland BC; Ferrand R; Vieillevigne L
    Phys Med Biol; 2015 Sep; 60(17):6669-83. PubMed ID: 26271097
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Systematic evaluation of photodetector performance for plastic scintillation dosimetry.
    Boivin J; Beddar S; Guillemette M; Beaulieu L
    Med Phys; 2015 Nov; 42(11):6211-20. PubMed ID: 26520714
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source.
    Jang KW; Yoo WJ; Moon J; Han KT; Park JY; Lee B
    Appl Radiat Isot; 2012 Jan; 70(1):274-7. PubMed ID: 21889353
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications.
    Lacroix F; Archambault L; Gingras L; Guillot M; Beddar AS; Beaulieu L
    Med Phys; 2008 Aug; 35(8):3682-90. PubMed ID: 18777928
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.