BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

830 related articles for article (PubMed ID: 32314932)

  • 1. Prostate Mapping for Cancer Diagnosis: The Madrid Protocol. Transperineal Prostate Biopsies Using Multiparametric Magnetic Resonance Imaging Fusion and Micro-Ultrasound Guided Biopsies.
    Rodríguez Socarrás ME; Gomez Rivas J; Cuadros Rivera V; Reinoso Elbers J; Llanes González L; Michel Mercado I; Fernandez Del Alamo J; Juarez Del Dago P; Sancha FG
    J Urol; 2020 Oct; 204(4):726-733. PubMed ID: 32314932
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Initial Experience with Transrectal Magnetic Resonance Imaging Cognitive Guided Micro-Ultrasound Biopsies versus Established Transperineal Robotic Ultrasound Magnetic Resonance Imaging Fusion Biopsies for Prostate Cancer.
    Claros OR; Tourinho-Barbosa RR; Fregeville A; Gallardo AC; Muttin F; Carneiro A; Stabile A; Moschini M; Macek P; Cathala N; Mombet A; Sanchez-Salas R; Cathelineau X
    J Urol; 2020 May; 203(5):918-925. PubMed ID: 31821099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative analysis of transperineal template saturation prostate biopsy versus magnetic resonance imaging targeted biopsy with magnetic resonance imaging-ultrasound fusion guidance.
    Radtke JP; Kuru TH; Boxler S; Alt CD; Popeneciu IV; Huettenbrink C; Klein T; Steinemann S; Bergstraesser C; Roethke M; Roth W; Schlemmer HP; Hohenfellner M; Hadaschik BA
    J Urol; 2015 Jan; 193(1):87-94. PubMed ID: 25079939
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.
    Mortezavi A; Märzendorfer O; Donati OF; Rizzi G; Rupp NJ; Wettstein MS; Gross O; Sulser T; Hermanns T; Eberli D
    J Urol; 2018 Aug; 200(2):309-318. PubMed ID: 29474846
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.
    Pal RP; Ahmad R; Trecartan S; Voss J; Ahmed S; Bazo A; Lloyd J; Walton TJ
    J Urol; 2018 Aug; 200(2):302-308. PubMed ID: 29477717
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Multicenter Study of the Clinical Utility of Nontargeted Systematic Transperineal Prostate Biopsies in Patients Undergoing Pre-Biopsy Multiparametric Magnetic Resonance Imaging.
    Connor MJ; Eldred-Evans D; van Son M; Hosking-Jervis F; Bertoncelli Tanaka M; Reddy D; Bass EJ; Powell L; Ahmad S; Pegers E; Joshi S; Sri D; Wong K; Tam H; Hrouda D; Qazi H; Gordon S; Winkler M; Ahmed HU
    J Urol; 2020 Dec; 204(6):1195-1201. PubMed ID: 32516029
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of Transperineal Targeted Prostate Biopsies, Visual Estimation and Image Fusion in Men Needing Repeat Biopsy in the PICTURE Trial.
    Simmons LAM; Kanthabalan A; Arya M; Briggs T; Barratt D; Charman SC; Freeman A; Hawkes D; Hu Y; Jameson C; McCartan N; Moore CM; Punwani S; van der Muelen J; Emberton M; Ahmed HU
    J Urol; 2018 Dec; 200(6):1227-1234. PubMed ID: 30017964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Critical evaluation of magnetic resonance imaging targeted, transrectal ultrasound guided transperineal fusion biopsy for detection of prostate cancer.
    Kuru TH; Roethke MC; Seidenader J; Simpfendörfer T; Boxler S; Alammar K; Rieker P; Popeneciu VI; Roth W; Pahernik S; Schlemmer HP; Hohenfellner M; Hadaschik BA
    J Urol; 2013 Oct; 190(4):1380-6. PubMed ID: 23608676
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiparametric MRI-ultrasonography software fusion prostate biopsy: initial results using a stereotactic robotic-assisted transperineal prostate biopsy platform comparing systematic vs targeted biopsy.
    Lee AYM; Yang XY; Lee HJ; Law YM; Huang HH; Lau WKO; Lee LS; Ho HSS; Tay KJ; Cheng CWS; Yuen JSP; Chen K
    BJU Int; 2020 Nov; 126(5):568-576. PubMed ID: 32438463
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multicentre evaluation of targeted and systematic biopsies using magnetic resonance and ultrasound image-fusion guided transperineal prostate biopsy in patients with a previous negative biopsy.
    Hansen NL; Kesch C; Barrett T; Koo B; Radtke JP; Bonekamp D; Schlemmer HP; Warren AY; Wieczorek K; Hohenfellner M; Kastner C; Hadaschik B
    BJU Int; 2017 Nov; 120(5):631-638. PubMed ID: 27862869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of significant prostate cancer with magnetic resonance targeted biopsies--should transrectal ultrasound-magnetic resonance imaging fusion guided biopsies alone be a standard of care?
    Delongchamps NB; Lefèvre A; Bouazza N; Beuvon F; Legman P; Cornud F
    J Urol; 2015 Apr; 193(4):1198-204. PubMed ID: 25451824
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Do cancer detection rates differ between transperineal and transrectal micro-ultrasound mpMRI-fusion-targeted prostate biopsies? A propensity score-matched study.
    Rakauskas A; Peters M; Martel P; van Rossum PSN; La Rosa S; Meuwly JY; Roth B; Valerio M
    PLoS One; 2023; 18(1):e0280262. PubMed ID: 36652429
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of real-time magnetic resonance imaging-transrectal ultrasound fusion image-guided transperineal target biopsy with needle tracking with a mechanical position-encoded stepper in detecting significant prostate cancer in biopsy-naïve men.
    Shoji S; Hiraiwa S; Ogawa T; Kawakami M; Nakano M; Hashida K; Sato Y; Hasebe T; Uchida T; Tajiri T
    Int J Urol; 2017 Apr; 24(4):288-294. PubMed ID: 28222486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transperineal Multiparametric Magnetic Resonance Imaging-Ultrasound Fusion Targeted Prostate Biopsy Combined with Standard Template Improves Prostate Cancer Detection.
    Kim MM; Wu S; Lin SX; Crotty RK; Harisinghani M; Feldman AS; Wu CL; Dahl DM
    J Urol; 2022 Jan; 207(1):86-94. PubMed ID: 34428921
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.
    Hansen N; Patruno G; Wadhwa K; Gaziev G; Miano R; Barrett T; Gnanapragasam V; Doble A; Warren A; Bratt O; Kastner C
    Eur Urol; 2016 Aug; 70(2):332-40. PubMed ID: 26995327
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systematic and MRI-Cognitive Targeted Transperineal Prostate Biopsy Accuracy in Detecting Clinically Significant Prostate Cancer after Previous Negative Biopsy and Persisting Suspicion of Malignancy.
    Vėželis A; Platkevičius G; Kinčius M; Gumbys L; Naruševičiūtė I; Briedienė R; Petroška D; Ulys A; Jankevičius F
    Medicina (Kaunas); 2021 Jan; 57(1):. PubMed ID: 33435132
    [No Abstract]   [Full Text] [Related]  

  • 17. A Multicentre Analysis of the Detection of Clinically Significant Prostate Cancer Following Transperineal Image-fusion Targeted and Nontargeted Systematic Prostate Biopsy in Men at Risk.
    Miah S; Hosking-Jervis F; Connor MJ; Eldred-Evans D; Shah TT; Arya M; Barber N; Bhardwa J; Bott S; Burke D; Doherty A; Foster C; Freeman A; Hindley R; Jameson C; Karim O; Laniado M; Montgomery B; Nigam R; Punwani S; Sinclair A; Winkler M; Allen C; Ahmed HU
    Eur Urol Oncol; 2020 Jun; 3(3):262-269. PubMed ID: 31411968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Micro-Ultrasound-Guided vs Multiparametric Magnetic Resonance Imaging-Targeted Biopsy in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis.
    Sountoulides P; Pyrgidis N; Polyzos SA; Mykoniatis I; Asouhidou E; Papatsoris A; Dellis A; Anastasiadis A; Lusuardi L; Hatzichristou D
    J Urol; 2021 May; 205(5):1254-1262. PubMed ID: 33577367
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Transrectal Ultrasound Biopsy to Transperineal Template Mapping Biopsies Stratified by Multiparametric Magnetic Resonance Imaging Score in the PROMIS Trial.
    Lovegrove CE; Miah S; El-Shater Bosaily A; Bott S; Brown L; Burns-Cox N; Dudderidge T; Freeman A; Henderson A; Hindley R; Kaplan R; Kirkham A; Oldroyd R; Parker C; Persad R; Punwani S; Rosario D; Shergill I; Winkler M; Emberton M; Ahmed HU
    J Urol; 2020 Jan; 203(1):100-107. PubMed ID: 31335254
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of real-time elastography on magnetic resonance imaging/ultrasound fusion guided biopsy in patients with prior negative prostate biopsies.
    Brock M; Löppenberg B; Roghmann F; Pelzer A; Dickmann M; Becker W; Martin-Seidel P; Sommerer F; Schenk L; Palisaar RJ; Noldus J; von Bodman C
    J Urol; 2015 Apr; 193(4):1191-7. PubMed ID: 25451832
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 42.