These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
157 related articles for article (PubMed ID: 32320971)
1. Computational model for detector timing effects in Compton-camera based prompt-gamma imaging for proton radiotherapy. Maggi P; Peterson S; Panthi R; Mackin D; Yang H; He Z; Beddar S; Polf J Phys Med Biol; 2020 Jun; 65(12):125004. PubMed ID: 32320971 [TBL] [Abstract][Full Text] [Related]
2. Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification. Polf JC; Avery S; Mackin DS; Beddar S Phys Med Biol; 2015 Sep; 60(18):7085-99. PubMed ID: 26317610 [TBL] [Abstract][Full Text] [Related]
3. The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification. Polf JC; Maggi P; Panthi R; Peterson S; Mackin D; Beddar S IEEE Trans Radiat Plasma Med Sci; 2022 Mar; 6(3):366-373. PubMed ID: 36092269 [TBL] [Abstract][Full Text] [Related]
4. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning. Jiang Z; Polf JC; Barajas CA; Gobbert MK; Ren L Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848674 [No Abstract] [Full Text] [Related]
5. 3D prompt gamma imaging for proton beam range verification. Draeger E; Mackin D; Peterson S; Chen H; Avery S; Beddar S; Polf JC Phys Med Biol; 2018 Jan; 63(3):035019. PubMed ID: 29380750 [TBL] [Abstract][Full Text] [Related]
6. Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation. Hilaire E; Sarrut D; Peyrin F; Maxim V Phys Med Biol; 2016 Apr; 61(8):3127-46. PubMed ID: 27008459 [TBL] [Abstract][Full Text] [Related]
7. Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy. Jan ML; Hsiao IT; Huang HM Med Phys; 2017 Dec; 44(12):6261-6269. PubMed ID: 29031024 [TBL] [Abstract][Full Text] [Related]
8. Noise evaluation of Compton camera imaging for proton therapy. Ortega PG; Torres-Espallardo I; Cerutti F; Ferrari A; Gillam JE; Lacasta C; Llosá G; Oliver JF; Sala PR; Solevi P; Rafecas M Phys Med Biol; 2015 Mar; 60(5):1845-63. PubMed ID: 25658644 [TBL] [Abstract][Full Text] [Related]
9. Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring. Valencia Lozano I; Dedes G; Peterson S; Mackin D; Zoglauer A; Beddar S; Avery S; Polf J; Parodi K Z Med Phys; 2023 May; 33(2):124-134. PubMed ID: 35750591 [TBL] [Abstract][Full Text] [Related]
10. Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based Polf JC; Barajas CA; Peterson SW; Mackin DS; Beddar S; Ren L; Gobbert MK Front Phys; 2022 Apr; 10():. PubMed ID: 36119562 [TBL] [Abstract][Full Text] [Related]
11. Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient. Polf JC; Mackin D; Lee E; Avery S; Beddar S Phys Med Biol; 2014 May; 59(9):2325-40. PubMed ID: 24732052 [TBL] [Abstract][Full Text] [Related]
12. A low-count reconstruction algorithm for Compton-based prompt gamma imaging. Huang HM; Liu CC; Jan ML; Lee MW Phys Med Biol; 2018 Apr; 63(8):085013. PubMed ID: 29546850 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy. Mackin D; Peterson S; Beddar S; Polf J Phys Med Biol; 2012 Jun; 57(11):3537-53. PubMed ID: 22588144 [TBL] [Abstract][Full Text] [Related]
14. Machine learning approach for proton range verification using real-time prompt gamma imaging with Compton cameras: addressing the total deposited energy information gap. Kazemi Kozani M Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38417182 [No Abstract] [Full Text] [Related]
15. A deep learning approach for converting prompt gamma images to proton dose distributions: A Monte Carlo simulation study. Liu CC; Huang HM Phys Med; 2020 Jan; 69():110-119. PubMed ID: 31869575 [TBL] [Abstract][Full Text] [Related]
16. Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy. Yao Z; Xiao Y; Chen Z; Wang B; Hou Q Sci Rep; 2019 Feb; 9(1):1133. PubMed ID: 30718671 [TBL] [Abstract][Full Text] [Related]
17. Analytical computation of prompt gamma ray emission and detection for proton range verification. Sterpin E; Janssens G; Smeets J; Vander Stappen F; Prieels D; Priegnitz M; Perali I; Vynckier S Phys Med Biol; 2015 Jun; 60(12):4915-46. PubMed ID: 26057053 [TBL] [Abstract][Full Text] [Related]
18. Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy. Peterson SW; Robertson D; Polf J Phys Med Biol; 2010 Nov; 55(22):6841-56. PubMed ID: 21048295 [TBL] [Abstract][Full Text] [Related]
19. The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras. Mackin D; Polf J; Peterson S; Beddar S Med Phys; 2013 Jan; 40(1):012402. PubMed ID: 23298111 [TBL] [Abstract][Full Text] [Related]
20. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study. Malekzadeh E; Rajabi H; Tajik-Mansoury MA; Sabouri P; Fiorina E; Kalantari F Med Phys; 2023 Jun; 50(6):3701-3718. PubMed ID: 36718592 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]