787 related articles for article (PubMed ID: 32325642)
1. A Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2.
Lu R; Wu X; Wan Z; Li Y; Jin X; Zhang C
Int J Mol Sci; 2020 Apr; 21(8):. PubMed ID: 32325642
[TBL] [Abstract][Full Text] [Related]
2. Development and Clinical Application of a Rapid and Sensitive Loop-Mediated Isothermal Amplification Test for SARS-CoV-2 Infection.
Hu X; Deng Q; Li J; Chen J; Wang Z; Zhang X; Fang Z; Li H; Zhao Y; Yu P; Li W; Wang X; Li S; Zhang L; Hou T
mSphere; 2020 Aug; 5(4):. PubMed ID: 32848011
[TBL] [Abstract][Full Text] [Related]
3. Loop mediated isothermal amplification (LAMP) assays as a rapid diagnostic for COVID-19.
Kashir J; Yaqinuddin A
Med Hypotheses; 2020 Aug; 141():109786. PubMed ID: 32361529
[TBL] [Abstract][Full Text] [Related]
4. A Multiplex and Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Sensitive and Rapid Detection of Novel SARS-CoV-2.
Juscamayta-López E; Valdivia F; Horna H; Tarazona D; Linares L; Rojas N; Huaringa M
Front Cell Infect Microbiol; 2021; 11():653616. PubMed ID: 34268131
[TBL] [Abstract][Full Text] [Related]
5. Validation of a single-step, single-tube reverse transcription loop-mediated isothermal amplification assay for rapid detection of SARS-CoV-2 RNA.
Lee JYH; Best N; McAuley J; Porter JL; Seemann T; Schultz MB; Sait M; Orlando N; Mercoulia K; Ballard SA; Druce J; Tran T; Catton MG; Pryor MJ; Cui HL; Luttick A; McDonald S; Greenhalgh A; Kwong JC; Sherry NL; Graham M; Hoang T; Herisse M; Pidot SJ; Williamson DA; Howden BP; Monk IR; Stinear TP
J Med Microbiol; 2020 Sep; 69(9):1169-1178. PubMed ID: 32755529
[No Abstract] [Full Text] [Related]
6. Multiplex reverse transcription loop-mediated isothermal amplification combined with nanoparticle-based lateral flow biosensor for the diagnosis of COVID-19.
Zhu X; Wang X; Han L; Chen T; Wang L; Li H; Li S; He L; Fu X; Chen S; Xing M; Chen H; Wang Y
Biosens Bioelectron; 2020 Oct; 166():112437. PubMed ID: 32692666
[TBL] [Abstract][Full Text] [Related]
7. Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP).
Mautner L; Baillie CK; Herold HM; Volkwein W; Guertler P; Eberle U; Ackermann N; Sing A; Pavlovic M; Goerlich O; Busch U; Wassill L; Huber I; Baiker A
Virol J; 2020 Oct; 17(1):160. PubMed ID: 33087160
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of rapid diagnosis of novel coronavirus disease (COVID-19) using loop-mediated isothermal amplification.
Kitagawa Y; Orihara Y; Kawamura R; Imai K; Sakai J; Tarumoto N; Matsuoka M; Takeuchi S; Maesaki S; Maeda T
J Clin Virol; 2020 Aug; 129():104446. PubMed ID: 32512376
[TBL] [Abstract][Full Text] [Related]
9. Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2.
Baek YH; Um J; Antigua KJC; Park JH; Kim Y; Oh S; Kim YI; Choi WS; Kim SG; Jeong JH; Chin BS; Nicolas HDG; Ahn JY; Shin KS; Choi YK; Park JS; Song MS
Emerg Microbes Infect; 2020 Dec; 9(1):998-1007. PubMed ID: 32306853
[TBL] [Abstract][Full Text] [Related]
10. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples.
Dao Thi VL; Herbst K; Boerner K; Meurer M; Kremer LP; Kirrmaier D; Freistaedter A; Papagiannidis D; Galmozzi C; Stanifer ML; Boulant S; Klein S; Chlanda P; Khalid D; Barreto Miranda I; Schnitzler P; Kräusslich HG; Knop M; Anders S
Sci Transl Med; 2020 Aug; 12(556):. PubMed ID: 32719001
[TBL] [Abstract][Full Text] [Related]
11. SARS-CoV-2 RNA Extraction Using Magnetic Beads for Rapid Large-Scale Testing by RT-qPCR and RT-LAMP.
Klein S; Müller TG; Khalid D; Sonntag-Buck V; Heuser AM; Glass B; Meurer M; Morales I; Schillak A; Freistaedter A; Ambiel I; Winter SL; Zimmermann L; Naumoska T; Bubeck F; Kirrmaier D; Ullrich S; Barreto Miranda I; Anders S; Grimm D; Schnitzler P; Knop M; Kräusslich HG; Dao Thi VL; Börner K; Chlanda P
Viruses; 2020 Aug; 12(8):. PubMed ID: 32784757
[TBL] [Abstract][Full Text] [Related]
12. A reverse-transcription recombinase-aided amplification assay for the rapid detection of N gene of severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).
Wu T; Ge Y; Zhao K; Zhu X; Chen Y; Wu B; Zhu F; Zhu B; Cui L
Virology; 2020 Oct; 549():1-4. PubMed ID: 32758712
[TBL] [Abstract][Full Text] [Related]
13. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay.
Yan C; Cui J; Huang L; Du B; Chen L; Xue G; Li S; Zhang W; Zhao L; Sun Y; Yao H; Li N; Zhao H; Feng Y; Liu S; Zhang Q; Liu D; Yuan J
Clin Microbiol Infect; 2020 Jun; 26(6):773-779. PubMed ID: 32276116
[TBL] [Abstract][Full Text] [Related]
14. iSCAN: An RT-LAMP-coupled CRISPR-Cas12 module for rapid, sensitive detection of SARS-CoV-2.
Ali Z; Aman R; Mahas A; Rao GS; Tehseen M; Marsic T; Salunke R; Subudhi AK; Hala SM; Hamdan SM; Pain A; Alofi FS; Alsomali A; Hashem AM; Khogeer A; Almontashiri NAM; Abedalthagafi M; Hassan N; Mahfouz MM
Virus Res; 2020 Oct; 288():198129. PubMed ID: 32822689
[TBL] [Abstract][Full Text] [Related]
15. Clinical Evaluation of Self-Collected Saliva by Quantitative Reverse Transcription-PCR (RT-qPCR), Direct RT-qPCR, Reverse Transcription-Loop-Mediated Isothermal Amplification, and a Rapid Antigen Test To Diagnose COVID-19.
Nagura-Ikeda M; Imai K; Tabata S; Miyoshi K; Murahara N; Mizuno T; Horiuchi M; Kato K; Imoto Y; Iwata M; Mimura S; Ito T; Tamura K; Kato Y
J Clin Microbiol; 2020 Aug; 58(9):. PubMed ID: 32636214
[TBL] [Abstract][Full Text] [Related]
16. Optimization and clinical validation of dual-target RT-LAMP for SARS-CoV-2.
Mohon AN; Oberding L; Hundt J; van Marle G; Pabbaraju K; Berenger BM; Lisboa L; Griener T; Czub M; Doolan C; Servellita V; Chiu CY; Greninger AL; Jerome KR; Pillai DR
J Virol Methods; 2020 Dec; 286():113972. PubMed ID: 32941977
[TBL] [Abstract][Full Text] [Related]
17. Development and Validation of a Rapid, Single-Step Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) System Potentially to Be Used for Reliable and High-Throughput Screening of COVID-19.
Jiang M; Pan W; Arasthfer A; Fang W; Ling L; Fang H; Daneshnia F; Yu J; Liao W; Pei H; Li X; Lass-Flörl C
Front Cell Infect Microbiol; 2020; 10():331. PubMed ID: 32626666
[No Abstract] [Full Text] [Related]
18. Rapid SARS-CoV-2 testing in primary material based on a novel multiplex RT-LAMP assay.
Schermer B; Fabretti F; Damagnez M; Di Cristanziano V; Heger E; Arjune S; Tanner NA; Imhof T; Koch M; Ladha A; Joung J; Gootenberg JS; Abudayyeh OO; Burst V; Zhang F; Klein F; Benzing T; Müller RU
PLoS One; 2020; 15(11):e0238612. PubMed ID: 33137122
[TBL] [Abstract][Full Text] [Related]
19. SARS-CoV-2 detection using isothermal amplification and a rapid, inexpensive protocol for sample inactivation and purification.
Rabe BA; Cepko C
Proc Natl Acad Sci U S A; 2020 Sep; 117(39):24450-24458. PubMed ID: 32900935
[TBL] [Abstract][Full Text] [Related]
20. A role for Biofoundries in rapid development and validation of automated SARS-CoV-2 clinical diagnostics.
Crone MA; Priestman M; Ciechonska M; Jensen K; Sharp DJ; Anand A; Randell P; Storch M; Freemont PS
Nat Commun; 2020 Sep; 11(1):4464. PubMed ID: 32900994
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]