These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32326506)

  • 1. Quantitative Measurements of Backside Wear in Acetabular Hip Joint Replacement: Conventional Polyethylene Versus Cross-Linked Polyethylene.
    Braun S; Jaeger S; Sonntag R; Schroeder S; Kretzer JP
    Materials (Basel); 2020 Apr; 13(8):. PubMed ID: 32326506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.
    Bali K; McCalden RW; Naudie DD; MacDonald SJ; Teeter MG
    Clin Orthop Relat Res; 2016 Feb; 474(2):374-82. PubMed ID: 26201422
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Backside wear in acetabular hip joint replacement.
    Braun S; Sonntag R; Schroeder S; Mueller U; Jaeger S; Gotterbarm T; Kretzer JP
    Acta Biomater; 2019 Jan; 83():467-476. PubMed ID: 30408561
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study.
    Tsukamoto M; Ohnishi H; Mori T; Kawasaki M; Uchida S; Sakai A
    J Arthroplasty; 2017 Jan; 32(1):161-165.e1. PubMed ID: 27444850
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene.
    Braun S; Vardag S; Mueller U; Schroeder S; Sonntag R; Bormann T; Gotterbarm T; Kretzer JP
    Acta Biomater; 2019 Oct; 97():239-246. PubMed ID: 31374340
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners.
    Pang HN; Naudie DD; McCalden RW; MacDonald SJ; Teeter MG
    Clin Orthop Relat Res; 2015 Feb; 473(2):463-8. PubMed ID: 25115585
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.
    Hopper RH; Ho H; Sritulanondha S; Williams AC; Engh CA
    Clin Orthop Relat Res; 2018 Feb; 476(2):279-290. PubMed ID: 29529656
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.
    Karidakis GK; Karachalios T
    Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator.
    Affatato S; Freccero N; Taddei P
    J Mech Behav Biomed Mater; 2016 Jan; 53():40-48. PubMed ID: 26301318
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test.
    Affatato S; De Mattia JS; Bracco P; Pavoni E; Taddei P
    J Mech Behav Biomed Mater; 2016 Dec; 64():240-52. PubMed ID: 27522313
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
    Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
    Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity.
    Nakashima Y; Sato T; Yamamoto T; Motomura G; Ohishi M; Hamai S; Akiyama M; Hirata M; Hara D; Iwamoto Y
    J Orthop Sci; 2013 Nov; 18(6):962-8. PubMed ID: 23963589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years.
    de Steiger R; Lorimer M; Graves SE
    J Bone Joint Surg Am; 2018 Aug; 100(15):1281-1288. PubMed ID: 30063590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty.
    Sato T; Nakashima Y; Akiyama M; Yamamoto T; Mawatari T; Itokawa T; Ohishi M; Motomura G; Hirata M; Iwamoto Y
    J Orthop Res; 2012 Dec; 30(12):2031-7. PubMed ID: 22644564
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term.
    Liu T; Esposito C; Elpers M; Wright T
    Clin Orthop Relat Res; 2016 Jan; 474(1):107-16. PubMed ID: 26084848
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear.
    Grupp TM; Holderied M; Mulliez MA; Streller R; Jäger M; Blömer W; Utzschneider S
    Acta Biomater; 2014 Jul; 10(7):3068-78. PubMed ID: 24631660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty.
    Schipper ON; Haddad SL; Fullam S; Pourzal R; Wimmer MA
    Foot Ankle Int; 2018 Nov; 39(11):1335-1344. PubMed ID: 30019605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of articular and backside polyethylene wear in mobile bearing unicompartmental knee replacement.
    Teeter MG; Howard JL; McCalden RW; Naudie DD
    Knee; 2017 Mar; 24(2):429-433. PubMed ID: 28189405
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene.
    Roussignol X; Siedlecki C; Duparc F; Dujardin F; Ould-Slimane M
    Orthop Traumatol Surg Res; 2016 Oct; 102(6):711-5. PubMed ID: 27318806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.