4. Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study. Tsukamoto M; Ohnishi H; Mori T; Kawasaki M; Uchida S; Sakai A J Arthroplasty; 2017 Jan; 32(1):161-165.e1. PubMed ID: 27444850 [TBL] [Abstract][Full Text] [Related]
5. Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene. Braun S; Vardag S; Mueller U; Schroeder S; Sonntag R; Bormann T; Gotterbarm T; Kretzer JP Acta Biomater; 2019 Oct; 97():239-246. PubMed ID: 31374340 [TBL] [Abstract][Full Text] [Related]
6. Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners. Pang HN; Naudie DD; McCalden RW; MacDonald SJ; Teeter MG Clin Orthop Relat Res; 2015 Feb; 473(2):463-8. PubMed ID: 25115585 [TBL] [Abstract][Full Text] [Related]
7. Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene. Hopper RH; Ho H; Sritulanondha S; Williams AC; Engh CA Clin Orthop Relat Res; 2018 Feb; 476(2):279-290. PubMed ID: 29529656 [TBL] [Abstract][Full Text] [Related]
8. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Karidakis GK; Karachalios T Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343 [TBL] [Abstract][Full Text] [Related]
9. The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator. Affatato S; Freccero N; Taddei P J Mech Behav Biomed Mater; 2016 Jan; 53():40-48. PubMed ID: 26301318 [TBL] [Abstract][Full Text] [Related]
10. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test. Affatato S; De Mattia JS; Bracco P; Pavoni E; Taddei P J Mech Behav Biomed Mater; 2016 Dec; 64():240-52. PubMed ID: 27522313 [TBL] [Abstract][Full Text] [Related]
11. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821 [TBL] [Abstract][Full Text] [Related]
12. Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity. Nakashima Y; Sato T; Yamamoto T; Motomura G; Ohishi M; Hamai S; Akiyama M; Hirata M; Hara D; Iwamoto Y J Orthop Sci; 2013 Nov; 18(6):962-8. PubMed ID: 23963589 [TBL] [Abstract][Full Text] [Related]
13. Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years. de Steiger R; Lorimer M; Graves SE J Bone Joint Surg Am; 2018 Aug; 100(15):1281-1288. PubMed ID: 30063590 [TBL] [Abstract][Full Text] [Related]
14. Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty. Sato T; Nakashima Y; Akiyama M; Yamamoto T; Mawatari T; Itokawa T; Ohishi M; Motomura G; Hirata M; Iwamoto Y J Orthop Res; 2012 Dec; 30(12):2031-7. PubMed ID: 22644564 [TBL] [Abstract][Full Text] [Related]
15. Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term. Liu T; Esposito C; Elpers M; Wright T Clin Orthop Relat Res; 2016 Jan; 474(1):107-16. PubMed ID: 26084848 [TBL] [Abstract][Full Text] [Related]
16. Biotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear. Grupp TM; Holderied M; Mulliez MA; Streller R; Jäger M; Blömer W; Utzschneider S Acta Biomater; 2014 Jul; 10(7):3068-78. PubMed ID: 24631660 [TBL] [Abstract][Full Text] [Related]
17. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757 [TBL] [Abstract][Full Text] [Related]
18. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Schipper ON; Haddad SL; Fullam S; Pourzal R; Wimmer MA Foot Ankle Int; 2018 Nov; 39(11):1335-1344. PubMed ID: 30019605 [TBL] [Abstract][Full Text] [Related]
19. Comparison of articular and backside polyethylene wear in mobile bearing unicompartmental knee replacement. Teeter MG; Howard JL; McCalden RW; Naudie DD Knee; 2017 Mar; 24(2):429-433. PubMed ID: 28189405 [TBL] [Abstract][Full Text] [Related]
20. Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene. Roussignol X; Siedlecki C; Duparc F; Dujardin F; Ould-Slimane M Orthop Traumatol Surg Res; 2016 Oct; 102(6):711-5. PubMed ID: 27318806 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]