These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32333433)

  • 21. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.
    Dijkman B; Wellens HJ
    J Cardiovasc Electrophysiol; 2000 Dec; 11(12):1309-19. PubMed ID: 11196552
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia.
    Kouakam C; Kacet S; Hazard JR; Ferraci A; Mansour H; Defaye P; Davy JM; Lambiez M;
    Europace; 2004 Jan; 6(1):32-42. PubMed ID: 14697724
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Innovative P-wave detection for discrimination between ventricular and supraventricular tachycardia in single-chamber ICDs: is the P-wave invisible during tachycardia?
    Xiong WW; Karam PY; Marsh JD; Varma N; Verdino RJ; Paydak H
    Europace; 2013 Jun; 15(6):827-34. PubMed ID: 23512155
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A pilot study examining the performance of polynomial-modeled ventricular shock electrograms for rhythm discrimination in implantable devices.
    Williams JL; Shusterman V; Saba S
    Pacing Clin Electrophysiol; 2006 Sep; 29(9):930-9. PubMed ID: 16981915
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO).
    Toquero J; Alzueta J; Mont L; Lozano IF; Barrera A; Berruezo A; Castro V; Peña JL; Fidalgo ML; Brugada J
    Europace; 2009 Jun; 11(6):727-33. PubMed ID: 19411676
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation.
    Corbisiero R; Lee MA; Nabert DR; Coman JA; Breiter DJ; Schwartz M; McKittrick E; Zhang Y
    Europace; 2006 Dec; 8(12):1057-61. PubMed ID: 17105781
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator.
    Dorian P; Philippon F; Thibault B; Kimber S; Sterns L; Greene M; Newman D; Gelaznikas R; Barr A;
    Heart Rhythm; 2004 Nov; 1(5):540-7. PubMed ID: 15851216
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates.
    Theuns DA; Rivero-Ayerza M; Goedhart DM; Miltenburg M; Jordaens LJ
    Europace; 2008 Sep; 10(9):1060-6. PubMed ID: 18662939
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators.
    Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L
    Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A new algorithm for rhythm discrimination in cardioverter defibrillators based on the initial voltage changes of the ventricular electrogram.
    Rojo-Alvarez JL; Arenal A; García-Alberola A; Ortiz M; Valdés M; Artés-Rodríguez A
    Europace; 2003 Jan; 5(1):77-82. PubMed ID: 12504645
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A new defibrillator discrimination algorithm utilizing electrogram morphology analysis.
    Gold MR; Hsu W; Marcovecchio AF; Olsovsky MR; Lang DJ; Shorofsky SR
    Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 2):179-82. PubMed ID: 9990626
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.
    Dijkman B; Wellens HJ
    J Cardiovasc Electrophysiol; 2000 Oct; 11(10):1105-15. PubMed ID: 11059974
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Automatic discrimination between supraventricular and ventricular tachycardia using a multilayer perceptron in implantable cardioverter defibrillators.
    Rojo-Alvarez JL; García-Alberola A; Arenal-Maíz A; Piñeiro-Ave J; Valdés-Chavarri M; Artés-Rodríguez A
    Pacing Clin Electrophysiol; 2002 Nov; 25(11):1599-604. PubMed ID: 12494618
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Usefulness of ICD electrograms analysis to distinguish endocardial vs epicardial ventricular tachycardia in arrhythmogenic right ventricular cardiomyopathy.
    Kodali S; Shirai Y; Callans DJ; Zado ES; Marchlinski FE; Santangeli P
    J Cardiovasc Electrophysiol; 2019 Sep; 30(9):1526-1534. PubMed ID: 31187564
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Overcoming the defects of a virtue: dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.
    Sweeney MO
    Circulation; 2006 Jun; 113(25):2862-4. PubMed ID: 16801472
    [No Abstract]   [Full Text] [Related]  

  • 36. Differentiation of ventricular and supraventricular tachycardias based on the analysis of the first postpacing interval after sequential anti-tachycardia pacing in implantable cardioverter-defibrillator patients.
    Arenal A; Ortiz M; Peinado R; Merino JL; Quesada A; Atienza F; Alberola AG; Ormaetxe J; Castellanos E; Rodriguez JC; Pérez N; García J; Boluda L; del Prado M; Artés A
    Heart Rhythm; 2007 Mar; 4(3):316-22. PubMed ID: 17341396
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Morphology discriminator feature for enhanced ventricular tachycardia discrimination in implantable cardioverter defibrillators.
    Duru F; Bauersfeld U; Rahn-Schönbeck M; Candinas R
    Pacing Clin Electrophysiol; 2000 Sep; 23(9):1365-74. PubMed ID: 11025892
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Tachyarrhythmia discriminator for implantable cardioverter-defibrillators in bundle branch block.
    Kapoor R; Tyagi S; Dohmen C; Oujiri J; Roth J; Rubenstein JC; Berger M
    Heart Rhythm; 2020 Sep; 17(9):1561-1565. PubMed ID: 32353586
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Reduction of inappropriate implantable cardioverter-defibrillator therapies using enhanced supraventricular tachycardia discriminators: the ReduceIT study.
    Geller JC; Wöhrle A; Busch M; Elsässer A; Kleemann T; Birkenhauer F; Bramlage P; Veltmann C;
    J Interv Card Electrophysiol; 2021 Aug; 61(2):339-348. PubMed ID: 32661865
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Diagnostic performance of a dual-chamber cardioverter defibrillator programmed with nominal settings: a European prospective study.
    Sadoul N; Jung W; Jordaens L; Leenhardt A; Santini M; Wolpert C; Aliot E;
    J Cardiovasc Electrophysiol; 2002 Jan; 13(1):25-32. PubMed ID: 11843479
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.