These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 32340436)
21. Covered and uncovered biliary metal stents provide similar relief of biliary obstruction during neoadjuvant therapy in pancreatic cancer: a randomized trial. Seo DW; Sherman S; Dua KS; Slivka A; Roy A; Costamagna G; Deviere J; Peetermans J; Rousseau M; Nakai Y; Isayama H; Kozarek R; Gastrointest Endosc; 2019 Oct; 90(4):602-612.e4. PubMed ID: 31276674 [TBL] [Abstract][Full Text] [Related]
22. A Case Series: Outcomes of Endoscopic Biliary Self-Expandable Metal Stent for Malignant Biliary Obstruction with Surgically Altered Anatomy. Yamauchi H; Kida M; Okuwaki K; Miyazawa S; Iwai T; Imaizumi H; Eiji M; Hasegawa R; Koizumi W Dig Dis Sci; 2016 Aug; 61(8):2436-2441. PubMed ID: 27033545 [TBL] [Abstract][Full Text] [Related]
23. Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study. Togawa O; Isayama H; Kawakami H; Nakai Y; Mohri D; Hamada T; Kogure H; Kawakubo K; Sakamoto N; Koike K; Kita H Saudi J Gastroenterol; 2018; 24(3):151-156. PubMed ID: 29652026 [TBL] [Abstract][Full Text] [Related]
24. A newly designed uncovered biliary stent for palliation of malignant obstruction: results of a prospective study. Lawrence C; Nieto J; Parsons WG; Roy A; Guda NM; Steinberg SE; Hasan MK; Bucobo JC; Nagula S; Dey ND; Buscaglia JM; BMC Gastroenterol; 2020 Jun; 20(1):184. PubMed ID: 32522161 [TBL] [Abstract][Full Text] [Related]
25. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction. Hori Y; Naitoh I; Hayashi K; Kondo H; Yoshida M; Shimizu S; Hirano A; Okumura F; Ando T; Jinno N; Takada H; Togawa S; Joh T J Gastroenterol Hepatol; 2018 Mar; 33(3):696-703. PubMed ID: 28902972 [TBL] [Abstract][Full Text] [Related]
26. Preoperative Biliary Drainage in Cases of Borderline Resectable Pancreatic Cancer Treated with Neoadjuvant Chemotherapy and Surgery. Tsuboi T; Sasaki T; Serikawa M; Ishii Y; Mouri T; Shimizu A; Kurihara K; Tatsukawa Y; Miyaki E; Kawamura R; Tsushima K; Murakami Y; Uemura K; Chayama K Gastroenterol Res Pract; 2016; 2016():7968201. PubMed ID: 26880897 [TBL] [Abstract][Full Text] [Related]
27. Outcomes of 6-mm diameter fully covered self-expandable metal stents for preoperative biliary drainage in pancreatic cancer. Nakagawa H; Takeda T; Okamoto T; Mie T; Kasuga A; Sasaki T; Ozaka M; Matsuda T; Igarashi Y; Sasahira N DEN Open; 2024 Apr; 4(1):e360. PubMed ID: 38601271 [TBL] [Abstract][Full Text] [Related]
28. Bridge to surgery using partially covered self-expandable metal stents (PCMS) in malignant biliary stricture: an acceptable paradigm? Pop GH; Richter JA; Sauer B; Rehan ME; Ho HC; Adams RB; Bauer T; Shami VM; Phillips MS; Kahaleh M Surg Endosc; 2011 Feb; 25(2):613-8. PubMed ID: 20632189 [TBL] [Abstract][Full Text] [Related]
29. Use of expandable metallic biliary stents in resectable pancreatic cancer. Wasan SM; Ross WA; Staerkel GA; Lee JH Am J Gastroenterol; 2005 Sep; 100(9):2056-61. PubMed ID: 16128952 [TBL] [Abstract][Full Text] [Related]
30. Partially covered self-expandable metallic stent for postoperative benign strictures associated with laparoscopy-assisted gastrectomy. Chung KH; Lee SH; Park JM; Lee JM; Shin CM; Ahn SH; Park do J; Kim HH; Ryu JK; Kim YT Gastric Cancer; 2016 Jan; 19(1):280-6. PubMed ID: 25503478 [TBL] [Abstract][Full Text] [Related]
31. Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study. Lee TH; Jung MK; Kim TK; Pack CG; Park YK; Kim SO; Park DH Gastrointest Endosc; 2019 Oct; 90(4):663-672.e2. PubMed ID: 31220446 [TBL] [Abstract][Full Text] [Related]
32. Comparison of Metal and Plastic Stents for Preoperative Biliary Drainage in Resectable and Borderline Resectable Periampullary Cancer: A Meta-Analysis and System Review. Liu P; Lin H; Chen Y; Wu YS; Tang M; Liu C J Laparoendosc Adv Surg Tech A; 2018 Sep; 28(9):1074-1082. PubMed ID: 29668371 [TBL] [Abstract][Full Text] [Related]
33. Utility of laser-cut covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a single-center experience. Marui S; Uza N; Yamazaki H; Ota S; Nakamura T; Yoshida H; Okada H; Hirano T; Kuwada T; Sogabe Y; Tomono T; Matsumori T; Morita T; Nishikawa Y; Tsuda M; Maruno T; Shiokawa M; Kodama Y; Seno H Endoscopy; 2020 Aug; 52(8):664-668. PubMed ID: 32316040 [TBL] [Abstract][Full Text] [Related]
34. Self-expanding metal stents for biliary drainage in patients with resectable pancreatic cancer: single-center experience with 79 cases. Singal AK; Ross WA; Guturu P; Varadhachary GR; Javle M; Jaganmohan SR; Raju RP; Fleming JB; Raju GS; Kuo YF; Lee JH Dig Dis Sci; 2011 Dec; 56(12):3678-84. PubMed ID: 21750930 [TBL] [Abstract][Full Text] [Related]