223 related articles for article (PubMed ID: 32344140)
1. Atlanto-Occipital Transarticular Screw Fixation for the Treatment of Traumatic Occipitocervical Instability in the Pediatric Population.
Hassler KR; Jamshidi R; Vail SJ; Connell MJ; Chundu K; Lettieri SC; Feiz-Erfan I
World Neurosurg; 2020 Aug; 140():e81-e86. PubMed ID: 32344140
[TBL] [Abstract][Full Text] [Related]
2. Occipital condyle to cervical spine fixation in the pediatric population.
Kosnik-Infinger L; Glazier SS; Frankel BM
J Neurosurg Pediatr; 2014 Jan; 13(1):45-53. PubMed ID: 24206344
[TBL] [Abstract][Full Text] [Related]
3. Pediatric occipitocervical fixation: radiographic criteria, surgical technique, and clinical outcomes based on experience of a single surgeon.
Martinez-Del-Campo E; Turner JD; Rangel-Castilla L; Soriano-Baron H; Kalb S; Theodore N
J Neurosurg Pediatr; 2016 Oct; 18(4):452-462. PubMed ID: 27286444
[TBL] [Abstract][Full Text] [Related]
4. Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients.
Anderson RC; Ragel BT; Mocco J; Bohman LE; Brockmeyer DL
J Neurosurg; 2007 Jul; 107(1 Suppl):36-42. PubMed ID: 17644919
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison of occiput-C1-C2 fixation techniques: C0-C1 transarticular screw and direct occiput condyle screw.
Takigawa T; Simon P; Espinoza Orías AA; Hong JT; Ito Y; Inoue N; An HS
Spine (Phila Pa 1976); 2012 May; 37(12):E696-701. PubMed ID: 22158063
[TBL] [Abstract][Full Text] [Related]
6. Occipitocervical fusion using a contoured rod and wire construct in children: a reappraisal of a vintage technique.
Klimo P; Astur N; Gabrick K; Warner WC; Muhlbauer MS
J Neurosurg Pediatr; 2013 Feb; 11(2):160-9. PubMed ID: 23157394
[TBL] [Abstract][Full Text] [Related]
7. Biomechanical analysis of occipitocervical stability afforded by three fixation techniques.
Helgeson MD; Lehman RA; Sasso RC; Dmitriev AE; Mack AW; Riew KD
Spine J; 2011 Mar; 11(3):245-50. PubMed ID: 21377608
[TBL] [Abstract][Full Text] [Related]
8. Feasible and accurate occipitoatlantal transarticular fixation: an anatomic study.
Senoglu M; Safavi-Abbasi S; Theodore N; Crawford NR; Sonntag VK
Neurosurgery; 2010 Mar; 66(3 Suppl Operative):173-7; discussion 177. PubMed ID: 20173567
[TBL] [Abstract][Full Text] [Related]
9. Anatomical suitability of C1-2 transarticular screw placement in pediatric patients.
Brockmeyer DL; York JE; Apfelbaum RI
J Neurosurg; 2000 Jan; 92(1 Suppl):7-11. PubMed ID: 10616051
[TBL] [Abstract][Full Text] [Related]
10. Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results.
Pait TG; Al-Mefty O; Boop FA; Arnautovic KI; Rahman S; Ceola W
J Neurosurg; 1999 Jan; 90(1 Suppl):1-7. PubMed ID: 10413118
[TBL] [Abstract][Full Text] [Related]
11. Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients.
Gluf WM; Brockmeyer DL
J Neurosurg Spine; 2005 Feb; 2(2):164-9. PubMed ID: 15739528
[TBL] [Abstract][Full Text] [Related]
12. Fusions at the craniovertebral junction.
Ahmed R; Traynelis VC; Menezes AH
Childs Nerv Syst; 2008 Oct; 24(10):1209-24. PubMed ID: 18389260
[TBL] [Abstract][Full Text] [Related]
13. Morphometric Trajectory Analysis for Occipital Condyle Screws.
Du YK; Li SY; Yang WJ; Wang XY; Bi YF; Dong J; Huang H; Gao F; Li GZ; Wei HW; Yang JK; Xi YM
Orthop Surg; 2020 Jun; 12(3):931-937. PubMed ID: 32495510
[TBL] [Abstract][Full Text] [Related]
14. Rigid Internal Fixation for Traumatic Cranio-Cervical Dissociation in Infants and Young Children.
Keen JR; Ayer RE; Taha A; Zouros A
Spine (Phila Pa 1976); 2019 Jan; 44(1):17-24. PubMed ID: 29894452
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical implications of extending occipitocervical instrumentation to include the subaxial spine.
Martin MD; Bruner HJ; Wolfla CE; Yoganandan N
Neurosurgery; 2010 Jun; 66(6):1148-52; discussion 1152. PubMed ID: 20495429
[TBL] [Abstract][Full Text] [Related]
16. Role of transarticular screw fixation in tuberculous atlanto-axial instability.
Bapat MR; Lahiri VJ; Harshavardhan NS; Metkar US; Chaudhary KC
Eur Spine J; 2007 Feb; 16(2):187-97. PubMed ID: 16482454
[TBL] [Abstract][Full Text] [Related]
17. Fixation with C-2 laminar screws in occipitocervical or C1-2 constructs in children 5 years of age or younger: a series of 18 patients.
Savage JG; Fulkerson DH; Sen AN; Thomas JG; Jea A
J Neurosurg Pediatr; 2014 Jul; 14(1):87-93. PubMed ID: 24784980
[TBL] [Abstract][Full Text] [Related]
18. Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities.
Grob D
J Orthop Sci; 2000; 5(1):82-7. PubMed ID: 10664444
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical and morphometric evaluation of occipital condyle for occipitocervical segmental fixation.
Hong JT; Takigawa T; Sugisaki K; Espinoza Orías AA; Inoue N; An HS
Neurol Med Chir (Tokyo); 2011; 51(10):701-6. PubMed ID: 22027245
[TBL] [Abstract][Full Text] [Related]
20. C2 pedicle screw and plate combined with C1 titanium cable fixation for the treatment of atlantoaxial instability not suitable for placement of C1 screw.
Xiao ZM; Zhan XL; Gong DF; Chen QF; Luo GB; Jiang H
J Spinal Disord Tech; 2008 Oct; 21(7):514-7. PubMed ID: 18836364
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]