These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 32349328)

  • 1. A Novel Analog Front End with Voltage-Dependent Input Impedance and Bandpass Amplification for Capacitive Biopotential Measurements.
    Nakamura H; Sakajiri Y; Ishigami H; Ueno A
    Sensors (Basel); 2020 Apr; 20(9):. PubMed ID: 32349328
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel high input impedance front-end for capacitive biopotential measurement.
    Wu R; Tang Y; Li Z; Zhang L; Yan F
    Med Biol Eng Comput; 2018 Aug; 56(8):1343-1355. PubMed ID: 29308545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The design of CMOS general-purpose analog front-end circuit with tunable gain and bandwidth for biopotential signal recording systems.
    Chen WM; Yang WC; Tsai TY; Chiueh H; Wu CY
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():4784-7. PubMed ID: 22255408
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comments on "A novel high input impedance front-end for capacitive biopotential measurement".
    Pallàs Areny R
    Med Biol Eng Comput; 2020 Feb; 58(2):267-269. PubMed ID: 31834611
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analog front-end measuring biopotential signal with effective offset rejection loop.
    Lim S; Kim H; Song H; Cho DI; Ko H
    Biomed Mater Eng; 2015; 26 Suppl 1():S935-41. PubMed ID: 26406095
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fully Integrated Biopotential Acquisition Analog Front-End IC.
    Song H; Park Y; Kim H; Ko H
    Sensors (Basel); 2015 Sep; 15(10):25139-56. PubMed ID: 26437404
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Non-Contact Measurements of Electrocardiogram and Cough-Associated Electromyogram from the Neck Using In-Pillow Common Cloth Electrodes: A Proof-of-Concept Study.
    Takano A; Ishigami H; Ueno A
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33530394
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A 2.55 NEF 76 dB CMRR DC-Coupled Fully Differential Difference Amplifier Based Analog Front End for Wearable Biomedical Sensors.
    Zhao Y; Shang Z; Lian Y
    IEEE Trans Biomed Circuits Syst; 2019 Oct; 13(5):918-926. PubMed ID: 31247560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wireless biopotential acquisition system for portable healthcare monitoring.
    Wang WS; Huang HY; Wu ZC; Chen SC; Wang WF; Wu CF; Luo CH
    J Med Eng Technol; 2011 Jul; 35(5):254-61. PubMed ID: 21619420
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 36 μW 1.1 mm2 Reconfigurable Analog Front-End for Cardiovascular and Respiratory Signals Recording.
    Xu J; Konijnenburg M; Ha H; van Wegberg R; Song S; Blanco-Almazan D; Van Hoof C; Van Helleputte N
    IEEE Trans Biomed Circuits Syst; 2018 Aug; 12(4):774-783. PubMed ID: 29993987
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A 16-Channel CMOS Chopper-Stabilized Analog Front-End ECoG Acquisition Circuit for a Closed-Loop Epileptic Seizure Control System.
    Wu CY; Cheng CH; Chen ZX
    IEEE Trans Biomed Circuits Syst; 2018 Jun; 12(3):543-553. PubMed ID: 29877818
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impedance measurement system for determination of capacitive electrode coupling.
    Eilebrecht B; Willkomm J; Pohl A; Wartzek T; Leonhardt S
    IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):682-9. PubMed ID: 24232629
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preamplifiers for non-contact capacitive biopotential measurements.
    Peng G; Ignjatovic Z; Bocko MF
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1482-5. PubMed ID: 24109979
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A low power, low noise Programmable Analog Front End (PAFE) for biopotential measurements.
    Adimulam MK; Divya A; Tejaswi K; Srinivas MB
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():3844-3847. PubMed ID: 29060736
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reconfigurable Sensor Analog Front-End Using Low-Noise Chopper-Stabilized Delta-Sigma Capacitance-to-Digital Converter.
    Kim H; Lee B; Mun Y; Kim J; Han K; Roh Y; Song D; Huh S; Ko H
    Micromachines (Basel); 2018 Jul; 9(7):. PubMed ID: 30424280
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A low-rank matrix factorization approach for joint harmonic and baseline noise suppression in biopotential signals.
    Zivanovic M; Niegowski M; Lecumberri P; Gómez M
    Comput Methods Programs Biomed; 2017 Apr; 141():59-71. PubMed ID: 28241969
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Insulating electrodes: a review on biopotential front ends for dielectric skin-electrode interfaces.
    Spinelli E; Haberman M
    Physiol Meas; 2010 Oct; 31(10):S183-98. PubMed ID: 20834109
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the effect of body capacitance to ground in tetrapolar bioimpedance measurements.
    Aliau-Bonet C; Pallas-Areny R
    IEEE Trans Biomed Eng; 2012 Dec; 59(12):3405-11. PubMed ID: 22955870
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low-Power High-Input-Impedance EEG Signal Acquisition SoC With Fully Integrated IA and Signal-Specific ADC for Wearable Applications.
    Tohidi M; Kargaard Madsen J; Moradi F
    IEEE Trans Biomed Circuits Syst; 2019 Dec; 13(6):1437-1450. PubMed ID: 31443053
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Triboelectricity in capacitive biopotential measurements.
    Wartzek T; Lammersen T; Eilebrecht B; Walter M; Leonhardt S
    IEEE Trans Biomed Eng; 2011 May; 58(5):1268-77. PubMed ID: 21177156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.