BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 32352634)

  • 1. Grayscale representation of infrared microscopy images by extended multiplicative signal correction for registration with histological images.
    Trukhan S; Tafintseva V; Tøndel K; Großerueschkamp F; Mosig A; Kovalev V; Gerwert K; Kohler A
    J Biophotonics; 2020 Aug; 13(8):e201960223. PubMed ID: 32352634
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully unsupervised inter-individual IR spectral histology of paraffinized tissue sections of normal colon.
    Nguyen TN; Jeannesson P; Groh A; Piot O; Guenot D; Gobinet C
    J Biophotonics; 2016 May; 9(5):521-32. PubMed ID: 26872124
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Unsupervised method for normalization of hematoxylin-eosin stain in histological images.
    Tosta TAA; de Faria PR; Servato JPS; Neves LA; Roberto GF; Martins AS; do Nascimento MZ
    Comput Med Imaging Graph; 2019 Oct; 77():101646. PubMed ID: 31539863
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of Deep Learning to Develop and Analyze Computational Hematoxylin and Eosin Staining of Prostate Core Biopsy Images for Tumor Diagnosis.
    Rana A; Lowe A; Lithgow M; Horback K; Janovitz T; Da Silva A; Tsai H; Shanmugam V; Bayat A; Shah P
    JAMA Netw Open; 2020 May; 3(5):e205111. PubMed ID: 32432709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Color normalization of faded H&E-stained histological images using spectral matching.
    Tosta TAA; de Faria PR; Neves LA; do Nascimento MZ
    Comput Biol Med; 2019 Aug; 111():103344. PubMed ID: 31279982
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The applicability of Fourier transform infrared microspectroscopy for correction against matrix effects in X-ray fluorescence microimaging of tissues.
    Szczerbowska-Boruchowska M; Stec P; Czyzycki M; Szczerbowski Z; Simon R; Baumbach T; Ziomber-Lisiak A
    Spectrochim Acta A Mol Biomol Spectrosc; 2023 May; 293():122468. PubMed ID: 36787676
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extended multiplicative signal correction for FTIR spectral quality test and pre-processing of infrared imaging data.
    Tafintseva V; Shapaval V; Smirnova M; Kohler A
    J Biophotonics; 2020 Mar; 13(3):e201960112. PubMed ID: 31793214
    [TBL] [Abstract][Full Text] [Related]  

  • 8. ATR-FTIR spectroscopy as adjunct method to the microscopic examination of hematoxylin and eosin-stained tissues in diagnosing lung cancer.
    Bangaoil R; Santillan A; Angeles LM; Abanilla L; Lim A; Ramos MC; Fellizar A; Guevarra L; Albano PM
    PLoS One; 2020; 15(5):e0233626. PubMed ID: 32469931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Extended multiplicative signal correction as a tool for separation and characterization of physical and chemical information in Fourier transform infrared microscopy images of cryo-sections of beef loin.
    Kohler A; Kirschner C; Oust A; Martens H
    Appl Spectrosc; 2005 Jun; 59(6):707-16. PubMed ID: 16053536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of hematoxylin and eosin staining on linear birefringence measurement of fibrous tissue structures in polarization microscopy.
    Deng L; Chen C; Yu W; Shao C; Shen Z; Wang Y; He C; Li H; Liu Z; He H; Ma H
    J Biomed Opt; 2023 Oct; 28(10):102909. PubMed ID: 37786544
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Image fusion of IR and optical microscopy for mapping of biomolecules in tissue.
    Al Jedani S; Whitley CA; Ellis BG; Triantafyllou A; Smith CI; Gunning PJ; Gardner P; Risk JM; Weightman P; Barrett SD
    Analyst; 2021 Sep; 146(19):5848-5854. PubMed ID: 34498612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nonlinear multicontrast microscopy of hematoxylin-and-eosin-stained histological sections.
    Tuer A; Tokarz D; Prent N; Cisek R; Alami J; Dumont DJ; Bakueva L; Rowlands J; Barzda V
    J Biomed Opt; 2010; 15(2):026018. PubMed ID: 20459263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Infrared spectral histopathology using haematoxylin and eosin (H&E) stained glass slides: a major step forward towards clinical translation.
    Pilling MJ; Henderson A; Shanks JH; Brown MD; Clarke NW; Gardner P
    Analyst; 2017 Apr; 142(8):1258-1268. PubMed ID: 27921102
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reversible Data Hiding in FTIR Microspectroscopy Images with Tamper Indication and Payload Error Correction.
    Fylakis A; Keskinarkaus A; Partala J; Saarakkala S; Seppänen T
    Biomed Res Int; 2017; 2017():7584852. PubMed ID: 29259987
    [TBL] [Abstract][Full Text] [Related]  

  • 15. HISTOBREAST, a collection of brightfield microscopy images of Haematoxylin and Eosin stained breast tissue.
    Buga RM; Totu T; Dumitru A; Costache M; Floroiu I; Sladoje N; Stanciu SG
    Sci Data; 2020 Jun; 7(1):169. PubMed ID: 32503988
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fourier transform infrared microspectroscopy as a diagnostic tool for distinguishing between normal and malignant human gastric tissue.
    Colagar AH; Chaichi MJ; Khadjvand T
    J Biosci; 2011 Sep; 36(4):669-77. PubMed ID: 21857113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multivariate image analysis of a set of FTIR microspectroscopy images of aged bovine muscle tissue combining image and design information.
    Kohler A; Bertrand D; Martens H; Hannesson K; Kirschner C; Ofstad R
    Anal Bioanal Chem; 2007 Oct; 389(4):1143-53. PubMed ID: 17639358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic Identification of Paraffin Pixels on FTIR Images Acquired on FFPE Human Samples.
    Boutegrabet W; Guenot D; Bouché O; Boulagnon-Rombi C; Marchal Bressenot A; Piot O; Gobinet C
    Anal Chem; 2021 Mar; 93(8):3750-3761. PubMed ID: 33590761
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synchrotron-based FTIR spectra of stained single cells. Towards a clinical application in pathology.
    Pijanka J; Sockalingum GD; Kohler A; Yang Y; Draux F; Parkes G; Lam KP; Collins D; Dumas P; Sandt C; van Pittius DG; Douce G; Manfait M; Untereiner V; Sulé-Suso J
    Lab Invest; 2010 May; 90(5):797-807. PubMed ID: 20125083
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated segmentation of routinely hematoxylin-eosin-stained microscopic images by combining support vector machine clustering and active contour models.
    Glotsos D; Spyridonos P; Cavouras D; Ravazoula P; Dadioti PA; Nikiforidis G
    Anal Quant Cytol Histol; 2004 Dec; 26(6):331-40. PubMed ID: 15678615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.