These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 32353803)

  • 21. Safety and Efficacy of Multipoint Pacing in Cardiac Resynchronization Therapy: The MultiPoint Pacing Trial.
    Niazi I; Baker J; Corbisiero R; Love C; Martin D; Sheppard R; Worley SJ; Varma N; Lee K; Tomassoni G;
    JACC Clin Electrophysiol; 2017 Dec; 3(13):1510-1518. PubMed ID: 29759832
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I.
    Leclercq C; Burri H; Curnis A; Delnoy PP; Rinaldi CA; Sperzel J; Lee K; Calò L; Vicentini A; Concha JF; Thibault B
    Eur Heart J; 2019 Sep; 40(35):2979-2987. PubMed ID: 30859220
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients.
    Pappone C; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Ryu K; Romano E; Saviano M; Baldi M; Pappone A; Ciaccio C; Giannelli L; Ionescu B; Petretta A; Vitale R; Fundaliotis A; Tavazzi L; Santinelli V
    Heart Rhythm; 2014 Mar; 11(3):394-401. PubMed ID: 24291411
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optimized single-point left ventricular pacing leads to improved resynchronization compared with multipoint pacing.
    San Antonio R; Guasch E; González-Ascaso A; Jiménez-Arjona R; Climent AM; Pujol-López M; Doltra A; Alarcón F; Garre P; Liberos A; Trotta O; Quinto L; Borràs R; Arbelo E; Roca-Luque I; Atienza F; Brugada J; Fernández-Avilés F; Guillem MS; Sitges M; Tolosana JM; Mont L
    Pacing Clin Electrophysiol; 2021 Mar; 44(3):519-527. PubMed ID: 33538337
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Multipoint pacing improves peripheral hemodynamic response: Noninvasive assessment using radial artery tonometry.
    Ciconte G; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Jiang C; Ryu K; Caporaso I; Stutz R; Winter D; Saviano M; Vitale R; Conti M; Santinelli V; Pappone C
    Pacing Clin Electrophysiol; 2018 Feb; 41(2):106-113. PubMed ID: 29222865
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improving cardiac resynchronization therapy response with multipoint left ventricular pacing: Twelve-month follow-up study.
    Pappone C; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Ryu K; Jordan CD; Romano E; Baldi M; Saviano M; Pappone A; Vitale R; Catalano C; Ciaccio C; Giannelli L; Ionescu B; Petretta A; Fragakis N; Fundaliotis A; Tavazzi L; Santinelli V
    Heart Rhythm; 2015 Jun; 12(6):1250-8. PubMed ID: 25678057
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Multipoint left ventricular pacing with large anatomical separation improves reverse remodeling and response to cardiac resynchronization therapy in responders and non-responders to conventional biventricular pacing.
    Schiedat F; Schöne D; Aweimer A; Bösche L; Ewers A; Gotzmann M; Patsalis PC; Mügge A; Kloppe A
    Clin Res Cardiol; 2020 Feb; 109(2):183-193. PubMed ID: 31152199
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Optimized temporary biventricular pacing acutely improves intraoperative cardiac output after weaning from cardiopulmonary bypass: a substudy of a randomized clinical trial.
    Wang DY; Richmond ME; Quinn TA; Mirani AJ; Rusanov A; Yalamanchi V; Weinberg AD; Cabreriza SE; Spotnitz HM
    J Thorac Cardiovasc Surg; 2011 Apr; 141(4):1002-8, 1008.e1. PubMed ID: 20800242
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimization of coronary sinus lead placement targeted to right-to-left delay in patients undergoing cardiac resynchronization therapy.
    Oddone D; Solari D; Arena G; Mureddu R; Nangah R; Giorgi D; Senatore G; Bottoni N; Giaccardi M; Laffi M; Giammaria M; Sitta N; Marras E; Cipolla E; Di Lorenzo F; Carpi R; Brignole M
    Europace; 2019 Mar; 21(3):502-510. PubMed ID: 30508076
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Heart failure study of multipoint pacing effects on ventriculoarterial coupling: Rationale and design of the HUMVEE trial.
    Chrysohoou C; Dilaveris P; Antoniou CK; Skiadas I; Konstantinou K; Gatzoulis K; Kallikazaros I; Tousoulis D
    Ann Noninvasive Electrocardiol; 2018 May; 23(3):e12510. PubMed ID: 29034563
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Interventricular and intra-left ventricular electromechanical delays in right ventricular paced patients with heart failure: implications for upgrading to biventricular stimulation.
    Bordachar P; Garrigue S; Lafitte S; Reuter S; Jaïs P; Haïssaguerre M; Clementy J
    Heart; 2003 Dec; 89(12):1401-5. PubMed ID: 14617545
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Design and rationale of the Impact of MultiPoint pacing in CRT patients with reduced RV-to-LV delay (IMAGE-CRT) study.
    Solimene F; Nigro G; Canciello M; Tavoletta V; Shopova G; Calvanese R; Rago A; La Rosa C; Nappi F; Viscusi M; Urraro F; Manzo G; Gallo P; Andriani A; Rovaris G; Palmisano P; Innocenti S; D'Onofrio A
    J Cardiovasc Med (Hagerstown); 2020 Mar; 21(3):250-258. PubMed ID: 32004245
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical outcome of left ventricular multipoint pacing versus conventional biventricular pacing in cardiac resynchronization therapy: a systematic review and meta-analysis.
    Hu F; Zheng L; Ding L; Du Z; Liang E; Wu L; Chen G; Fan X; Yao Y; Jiang Y
    Heart Fail Rev; 2018 Nov; 23(6):927-934. PubMed ID: 30209643
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial.
    Upadhyay GA; Vijayaraman P; Nayak HM; Verma N; Dandamudi G; Sharma PS; Saleem M; Mandrola J; Genovese D; Oren JW; Subzposh FA; Aziz Z; Beaser A; Shatz D; Besser S; Lang RM; Trohman RG; Knight BP; Tung R;
    Heart Rhythm; 2019 Dec; 16(12):1797-1807. PubMed ID: 31096064
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Body surface mapping using an ECG belt to characterize electrical heterogeneity for different left ventricular pacing sites during cardiac resynchronization: Relationship with acute hemodynamic improvement.
    Johnson WB; Vatterott PJ; Peterson MA; Bagwe S; Underwood RD; Bank AJ; Gage RM; Ramza B; Foreman BW; Splett V; Haddad T; Gillberg JM; Ghosh S
    Heart Rhythm; 2017 Mar; 14(3):385-391. PubMed ID: 27871987
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of multipoint pacing on projected battery longevity in cardiac resynchronization therapy. An IRON-MPP study sub-analysis.
    Forleo GB; Gasperetti A; Ricciardi D; Curnis A; Bertaglia E; Calò L; Pignalberi C; Calzolari V; Ribatti V; Lavalle C; Potenza D; Tondi L; Natale V; Notarstefano P; Viecca M; Morani G; Biffi M; Giammaria M; Zanon F; Santini L
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2885-2891. PubMed ID: 31661172
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Paced left ventricular QRS width and ECG parameters predict outcomes after cardiac resynchronization therapy: PROSPECT-ECG substudy.
    Hsing JM; Selzman KA; Leclercq C; Pires LA; McLaughlin MG; McRae SE; Peterson BJ; Zimetbaum PJ
    Circ Arrhythm Electrophysiol; 2011 Dec; 4(6):851-7. PubMed ID: 21956038
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy.
    Vanderheyden M; De Backer T; Rivero-Ayerza M; Geelen P; Bartunek J; Verstreken S; De Zutter M; Goethals M
    Heart Rhythm; 2005 Oct; 2(10):1066-72. PubMed ID: 16188583
    [TBL] [Abstract][Full Text] [Related]  

  • 39. QRS morphology, left ventricular lead location, and clinical outcome in patients receiving cardiac resynchronization therapy.
    Kandala J; Upadhyay GA; Altman RK; Parks KA; Orencole M; Mela T; Kevin Heist E; Singh JP
    Eur Heart J; 2013 Aug; 34(29):2252-62. PubMed ID: 23571836
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of the longest intrapatient left ventricular electrical delay may predict acute hemodynamic improvement in patients after cardiac resynchronization therapy.
    Zanon F; Baracca E; Pastore G; Fraccaro C; Roncon L; Aggio S; Noventa F; Mazza A; Prinzen F
    Circ Arrhythm Electrophysiol; 2014 Jun; 7(3):377-83. PubMed ID: 24668162
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.