These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 32357743)

  • 1. Direct approach to determine the size setting error and size resolution of an optical particle counter.
    Geisler M; Dirscherl K
    Rev Sci Instrum; 2020 Apr; 91(4):045105. PubMed ID: 32357743
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of Mie theory for enhanced size determination of microparticles using optical particle counters.
    Müller D; Glöckler F; Kienle A
    Appl Opt; 2019 Jun; 58(17):4575-4584. PubMed ID: 31251277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct Reading Particle Counters: Calibration Verification and Multiple Instrument Agreement via Bump Testing.
    Jankovic J; Zontek TL; Ogle BR; Hollenbeck S
    J Occup Environ Hyg; 2015; 12(7):D116-22. PubMed ID: 25625686
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The evaluation of sizing accuracy of particle counters for parenteral drugs.
    Fujishita O; Sendo T; Hisazumi A; Otsubo K; Aoyama T; Oishi R
    PDA J Pharm Sci Technol; 1995; 49(6):267-71. PubMed ID: 8581457
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between two different nanoparticle size spectrometers.
    Belosi F; Ferrari S; Poluzzi V; Santachiara G; Prodi F
    J Air Waste Manag Assoc; 2013 Aug; 63(8):918-25. PubMed ID: 24010372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new coincidence model for single particle counters, Part II: Advances and applications.
    Knapp JZ; Lieberman A; Abramson LR
    PDA J Pharm Sci Technol; 1994; 48(5):255-92. PubMed ID: 8000900
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A procedure to verify the lower counting limit of optical particle counters.
    Caldow R; Blesener J
    J Parenter Sci Technol; 1989; 43(4):174-9. PubMed ID: 2769524
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microprocessor controlled particle counter system.
    Lieberman A
    J Parenter Sci Technol; 1990; 44(3):133-8. PubMed ID: 2370623
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Workplace aerosol mass concentration measurement using optical particle counters.
    Görner P; Simon X; Bémer D; Lidén G
    J Environ Monit; 2012 Feb; 14(2):420-8. PubMed ID: 22009365
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Facility for calibration of optical and condensation particle counters based on a turbulent aerosol mixing tube and a reference optical particle counter.
    Horender S; Auderset K; Vasilatou K
    Rev Sci Instrum; 2019 Jul; 90(7):075111. PubMed ID: 31370453
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Variance Between Different Light Obscuration and Flow Imaging Microscopy Instruments and the Impact of Instrument Calibration.
    Matter A; Koulov A; Singh S; Mahler HC; Reinisch H; Langer C; Zucol B; Mathaes R
    J Pharm Sci; 2019 Jul; 108(7):2397-2405. PubMed ID: 30844365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
    Cohen BS; Heikkinen MS; Hazi Y; Gao H; Peters P; Lippmann M
    Res Rep Health Eff Inst; 2004 Sep; (121):1-35; discussion 37-46. PubMed ID: 15553489
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Small-angle light scattering: instrumental design and application to particle sizing.
    Alexander M; Hallett FR
    Appl Opt; 1999 Jul; 38(19):4158-63. PubMed ID: 18323896
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Universal inherent fluctuations in statistical counting of large particles in slurry used for semiconductor manufacturing.
    Lee M; Kim D; Heo TY; Park T; Kim W; Choi D; Kim H; Kim J
    Sci Rep; 2020 Sep; 10(1):14731. PubMed ID: 32895450
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Erratum: Preparation of Poly(pentafluorophenyl acrylate) Functionalized SiO2 Beads for Protein Purification.
    J Vis Exp; 2019 Apr; (146):. PubMed ID: 31038480
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Light-Scattering Sizing of Single Submicron Particles by High-Sensitivity Flow Cytometry.
    Zhang W; Tian Y; Hu X; He S; Niu Q; Chen C; Zhu S; Yan X
    Anal Chem; 2018 Nov; 90(21):12768-12775. PubMed ID: 30277744
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and CFD Analysis of the Fluid Dynamic Sampling System of the "MicroMED" Optical Particle Counter.
    Mongelluzzo G; Esposito F; Cozzolino F; Franzese G; Ruggeri AC; Porto C; Molfese C; Scaccabarozzi D; Saggin B
    Sensors (Basel); 2019 Nov; 19(22):. PubMed ID: 31752266
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new coincidence model for single particle counters, Part I: Theory and experimental verification.
    Knapp JZ; Abramson LR
    J Pharm Sci Technol; 1994; 48(3):110-34. PubMed ID: 8069513
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-Speed Multipass Coulter Counter with Ultrahigh Resolution.
    Edwards MA; German SR; Dick JE; Bard AJ; White HS
    ACS Nano; 2015 Dec; 9(12):12274-82. PubMed ID: 26549738
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Enhanced detection and sizing algorithm to improve LOAC optical particle counter performances.
    Verdier N; Papy JM; Renard JB; Lefevre M; Agrapart C
    Appl Opt; 2020 Dec; 59(34):10892-10901. PubMed ID: 33361910
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.