BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 32367365)

  • 21. One-step RT-qPCR assay for ZIKV RNA detection in Aedes aegypti samples: a protocol to study infection and gene expression during ZIKV infection.
    Araujo RV; Feitosa-Suntheimer F; Gold AS; Londono-Renteria B; Colpitts TM
    Parasit Vectors; 2020 Mar; 13(1):128. PubMed ID: 32171303
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Rapid molecular diagnostic test for Zika virus with low demands on sample preparation and instrumentation.
    Eboigbodin KE; Brummer M; Ojalehto T; Hoser M
    Diagn Microbiol Infect Dis; 2016 Dec; 86(4):369-371. PubMed ID: 27645608
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simultaneous diagnosis of dengue virus, Chikungunya virus, and Zika virus infection using a new point-of-care testing (POCT) system based on the loop-mediated isothermal amplification (LAMP) method.
    Kutsuna S; Saito S; Ohmagari N
    J Infect Chemother; 2020 Dec; 26(12):1249-1253. PubMed ID: 32713745
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Development and field validation of a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP) for the rapid detection of chikungunya virus in patient and mosquito samples.
    Silva SJRD; Magalhães JJF; Matthews Q; Divarzak ALL; Mendes RPG; Santos BNR; Cabral DGA; Silva JBD; Kohl A; Pardee K; Pena L
    Clin Microbiol Infect; 2024 Jun; 30(6):810-815. PubMed ID: 38460820
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Simpler, Faster, and Sensitive Zika Virus Assay Using Smartphone Detection of Loop-mediated Isothermal Amplification on Paper Microfluidic Chips.
    Kaarj K; Akarapipad P; Yoon JY
    Sci Rep; 2018 Aug; 8(1):12438. PubMed ID: 30127503
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Simultaneous Detection of Different Zika Virus Lineages via Molecular Computation in a Point-of-Care Assay.
    Bhadra S; Saldaña MA; Han HG; Hughes GL; Ellington AD
    Viruses; 2018 Dec; 10(12):. PubMed ID: 30558136
    [TBL] [Abstract][Full Text] [Related]  

  • 27. JEV-nanobarcode and colorimetric reverse transcription loop-mediated isothermal amplification (cRT-LAMP).
    Ahn G; Lee SH; Song MS; Han BK; Kim YH; Ahn JY
    Mikrochim Acta; 2021 Sep; 188(10):333. PubMed ID: 34498149
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Smartphone clip-on instrument and microfluidic processor for rapid sample-to-answer detection of Zika virus in whole blood using spatial RT-LAMP.
    Jankelow AM; Lee H; Wang W; Hoang TH; Bacon A; Sun F; Chae S; Kindratenko V; Koprowski K; Stavins RA; Ceriani DD; Engelder ZW; King WP; Do MN; Bashir R; Valera E; Cunningham BT
    Analyst; 2022 Aug; 147(17):3838-3853. PubMed ID: 35726910
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva.
    Sabalza M; Yasmin R; Barber CA; Castro T; Malamud D; Kim BJ; Zhu H; Montagna RA; Abrams WR
    PLoS One; 2018; 13(2):e0192398. PubMed ID: 29401479
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development and evaluation of a rapid molecular diagnostic test for Zika virus infection by reverse transcription loop-mediated isothermal amplification.
    Kurosaki Y; Martins DBG; Kimura M; Catena ADS; Borba MACSM; Mattos SDS; Abe H; Yoshikawa R; de Lima Filho JL; Yasuda J
    Sci Rep; 2017 Oct; 7(1):13503. PubMed ID: 29044149
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of Aptima Zika Virus Assay.
    Ren P; Ortiz DA; Terzian ACB; Colombo TE; Nogueira ML; Vasilakis N; Loeffelholz MJ
    J Clin Microbiol; 2017 Jul; 55(7):2198-2203. PubMed ID: 28468854
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Zika Virus Amplification Using Strand Displacement Isothermal Method and Sequencing Using Nanopore Technology.
    Hansen S; Faye O; Sanabani SS; Faye M; Böhlken-Fascher S; Faye O; Sall AA; Bekaert M; Weidmann M; Czerny CP; Abd El Wahed A
    Methods Mol Biol; 2020; 2142():123-136. PubMed ID: 32367364
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of a field-deployable reverse transcription-insulated isothermal PCR for rapid and sensitive on-site detection of Zika virus.
    Carossino M; Li Y; Lee PA; Tsai CF; Chou PH; Williams D; Skillman A; Frank Cook R; Brown G; Chang HG; Wang HT; Balasuriya UBR
    BMC Infect Dis; 2017 Dec; 17(1):778. PubMed ID: 29258444
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimizing PCR Detection of Zika Virus from Various Body Fluids.
    Gorchakov R; Berry RM; Patel SM; El Sahly HM; Ronca SE; Murray KO
    Am J Trop Med Hyg; 2019 Feb; 100(2):427-433. PubMed ID: 30560770
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Valve-Enabled Sample Preparation and RNA Amplification in a Coffee Mug for Zika Virus Detection.
    Jiang X; Loeb JC; Manzanas C; Lednicky JA; Fan ZH
    Angew Chem Int Ed Engl; 2018 Dec; 57(52):17211-17214. PubMed ID: 30358036
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Detection of Zika virus in urine.
    Gourinat AC; O'Connor O; Calvez E; Goarant C; Dupont-Rouzeyrol M
    Emerg Infect Dis; 2015 Jan; 21(1):84-6. PubMed ID: 25530324
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Establishment of a novel one-step reverse transcription loop-mediated isothermal amplification assay for rapid identification of RNA from the severe fever with thrombocytopenia syndrome virus.
    Xu H; Zhang L; Shen G; Feng C; Wang X; Yan J; Zhang Y
    J Virol Methods; 2013 Dec; 194(1-2):21-5. PubMed ID: 23911296
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hybridization Cascade Plus Strand-Displacement Isothermal Amplification of RNA Target with Secondary Structure Motifs and Its Application for Detecting Dengue and Zika Viruses.
    Saisuk W; Srisawat C; Yoksan S; Dharakul T
    Anal Chem; 2019 Mar; 91(5):3286-3293. PubMed ID: 30742406
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Instrument-Free Point-of-Care Molecular Detection of Zika Virus.
    Song J; Mauk MG; Hackett BA; Cherry S; Bau HH; Liu C
    Anal Chem; 2016 Jul; 88(14):7289-94. PubMed ID: 27306491
    [TBL] [Abstract][Full Text] [Related]  

  • 40. RT-dPCR in Mosquito Samples for ZIKV Detection: Effects of RNA Extraction and Reverse Transcription in Target Concentration.
    Almeida PR; Eisen AKA; Demoliner M; Spilki FR
    Viruses; 2020 Jul; 12(8):. PubMed ID: 32751540
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.