These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 32376278)

  • 1. Quantifying the impact from stroke during support with continuous flow ventricular assist devices: An STS INTERMACS analysis.
    Kirklin JK; Naftel DC; Myers SL; Pagani FD; Colombo PC
    J Heart Lung Transplant; 2020 Aug; 39(8):782-794. PubMed ID: 32376278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Society of Thoracic Surgeons Intermacs database annual report: Evolving indications, outcomes, and scientific partnerships.
    Kormos RL; Cowger J; Pagani FD; Teuteberg JJ; Goldstein DJ; Jacobs JP; Higgins RS; Stevenson LW; Stehlik J; Atluri P; Grady KL; Kirklin JK
    J Heart Lung Transplant; 2019 Feb; 38(2):114-126. PubMed ID: 30691593
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Left ventricular assist device outcomes based on flow configuration and pre-operative left ventricular dimension: An Interagency Registry for Mechanically Assisted Circulatory Support Analysis.
    Shah P; Birk S; Maltais S; Stulak J; Elmi A; Pagani FD; Cowger JA
    J Heart Lung Transplant; 2017 Jun; 36(6):640-649. PubMed ID: 28087105
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Society of Thoracic Surgeons Intermacs Database Annual Report: Evolving Indications, Outcomes, and Scientific Partnerships.
    Kormos RL; Cowger J; Pagani FD; Teuteberg JJ; Goldstein DJ; Jacobs JP; Higgins RS; Stevenson LW; Stehlik J; Atluri P; Grady KL; Kirklin JK
    Ann Thorac Surg; 2019 Feb; 107(2):341-353. PubMed ID: 30691584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score-Matched Analysis From the Intermacs Registry.
    Cho SM; Mehaffey JH; Meyers SL; Cantor RS; Starling RC; Kirklin JK; Jacobs JP; Kern J; Uchino K; Yarboro LT
    Circulation; 2021 Sep; 144(10):763-772. PubMed ID: 34491776
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cerebrovascular Events in Patients With Centrifugal-Flow Left Ventricular Assist Devices: Propensity Score-Matched Analysis From the Intermacs Registry.
    Cho SM; Mehaffey JH; Meyers SL; Cantor RS; Starling RC; Kirklin JK; Jacobs JP; Kern J; Uchino K; Yarboro LT
    Circulation; 2021 Sep; 144(10):763-772. PubMed ID: 34315231
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulmonary Arterial Elastance and INTERMACS-Defined Right Heart Failure Following Left Ventricular Assist Device.
    Muslem R; Ong CS; Tomashitis B; Schultz J; Ramu B; Craig ML; Van Bakel AB; Gilotra NA; Sharma K; Hsu S; Whitman GJ; Leary PJ; Cogswell R; Lozonschi L; Houston BA; Zijlstra F; Caliskan K; Bogers AJJC; Tedford RJ
    Circ Heart Fail; 2019 Aug; 12(8):e005923. PubMed ID: 31401840
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of Asian-Americans Implanted With Left Ventricular Assist Devices: An Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Analysis.
    Taleb I; Wever-Pinzon J; Wang W; Koliopoulou A; Dranow E; Yu T; Yin L; McKellar SH; Stehlik J; Fang JC; Wever-Pinzon O; Selzman CH; Drakos SG
    Heart Lung Circ; 2020 Aug; 29(8):1226-1233. PubMed ID: 32085955
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evolution of Late Right Heart Failure With Left Ventricular Assist Devices and Association With Outcomes.
    Rame JE; Pagani FD; Kiernan MS; Oliveira GH; Birati EY; Atluri P; Gaffey A; Grandin EW; Myers SL; Collum C; Kormos RL; Kirklin JK; Teuteberg JJ
    J Am Coll Cardiol; 2021 Dec; 78(23):2294-2308. PubMed ID: 34857091
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Five-Year Outcomes in Patients With Fully Magnetically Levitated vs Axial-Flow Left Ventricular Assist Devices in the MOMENTUM 3 Randomized Trial.
    Mehra MR; Goldstein DJ; Cleveland JC; Cowger JA; Hall S; Salerno CT; Naka Y; Horstmanshof D; Chuang J; Wang A; Uriel N
    JAMA; 2022 Sep; 328(12):1233-1242. PubMed ID: 36074476
    [TBL] [Abstract][Full Text] [Related]  

  • 11. INTERMACS Analysis of Stroke During Support With Continuous-Flow Left Ventricular Assist Devices: Risk Factors and Outcomes.
    Acharya D; Loyaga-Rendon R; Morgan CJ; Sands KA; Pamboukian SV; Rajapreyar I; Holman WL; Kirklin JK; Tallaj JA
    JACC Heart Fail; 2017 Oct; 5(10):703-711. PubMed ID: 28958345
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Society of Thoracic Surgeons Intermacs 2020 Annual Report.
    Molina EJ; Shah P; Kiernan MS; Cornwell WK; Copeland H; Takeda K; Fernandez FG; Badhwar V; Habib RH; Jacobs JP; Koehl D; Kirklin JK; Pagani FD; Cowger JA
    Ann Thorac Surg; 2021 Mar; 111(3):778-792. PubMed ID: 33465365
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Third Annual Report From the ISHLT Mechanically Assisted Circulatory Support Registry: A comparison of centrifugal and axial continuous-flow left ventricular assist devices.
    Goldstein DJ; Meyns B; Xie R; Cowger J; Pettit S; Nakatani T; Netuka I; Shaw S; Yanase M; Kirklin JK
    J Heart Lung Transplant; 2019 Apr; 38(4):352-363. PubMed ID: 30945637
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Eighth annual INTERMACS report: Special focus on framing the impact of adverse events.
    Kirklin JK; Pagani FD; Kormos RL; Stevenson LW; Blume ED; Myers SL; Miller MA; Baldwin JT; Young JB; Naftel DC
    J Heart Lung Transplant; 2017 Oct; 36(10):1080-1086. PubMed ID: 28942782
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device.
    Kirklin JK; Naftel DC; Kormos RL; Pagani FD; Myers SL; Stevenson LW; Acker MA; Goldstein DL; Silvestry SC; Milano CA; Baldwin JT; Pinney S; Eduardo Rame J; Miller MA
    J Heart Lung Transplant; 2014 Jan; 33(1):12-22. PubMed ID: 24418730
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative analysis of regional outcomes and adverse events after continuous-flow left ventricular assist device implantation: An IMACS analysis.
    Mirza KK; Xie R; Cowger J; Kirklin JK; Meyns B; Gustafsson F; Shaw SM; Goldstein DJ
    J Heart Lung Transplant; 2020 Sep; 39(9):904-914. PubMed ID: 32487472
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adverse events in contemporary continuous-flow left ventricular assist devices: A multi-institutional comparison shows significant differences.
    Stulak JM; Davis ME; Haglund N; Dunlay S; Cowger J; Shah P; Pagani FD; Aaronson KD; Maltais S
    J Thorac Cardiovasc Surg; 2016 Jan; 151(1):177-89. PubMed ID: 26545967
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.
    Kiernan MS; Grandin EW; Brinkley M; Kapur NK; Pham DT; Ruthazer R; Rame JE; Atluri P; Birati EY; Oliveira GH; Pagani FD; Kirklin JK; Naftel D; Kormos RL; Teuteberg JJ; DeNofrio D
    Circ Heart Fail; 2017 Oct; 10(10):. PubMed ID: 29021348
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Durability of left ventricular assist devices: Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 2006 to 2011.
    Holman WL; Naftel DC; Eckert CE; Kormos RL; Goldstein DJ; Kirklin JK
    J Thorac Cardiovasc Surg; 2013 Aug; 146(2):437-41.e1. PubMed ID: 23490245
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Left Ventricular End-Diastolic Dimension and Clinical Outcomes After Centrifugal Flow Left Ventricular Assist Device Implantation.
    Truong VT; Shreenivas S; Mazur W; Egnaczyk GF; Palmer C; Rao SD; Rame JE; Chung ES
    ASAIO J; 2022 Feb; 68(2):220-225. PubMed ID: 33927084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.