BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 32385540)

  • 1. Very late-phase vascular response after everolimus-eluting stent implantation assessed by optical coherence tomography.
    Khalifa AKM; Ino Y; Kubo T; Tanimoto T; Shimamura K; Shiono Y; Takahata M; Terada K; Higashioka D; Wada T; Taruya A; Emori H; Katayama Y; Kashiwagi M; Kuroi A; Matsuo Y; Fujita S; Tanaka A; Hozumi T; Akasaka T
    Int J Cardiovasc Imaging; 2020 Sep; 36(9):1627-1635. PubMed ID: 32385540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial.
    Xu B; Zhang YJ; Sun ZW; Qiao SB; Chen SL; Zhang RY; Pan DR; Pang S; Zhang Q; Xu L; Yang YJ; Leon MB; Gao RL
    Int J Cardiovasc Imaging; 2015 Dec; 31(8):1489-96. PubMed ID: 26208685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.
    Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K
    Int J Cardiovasc Imaging; 2018 Apr; 34(4):515-522. PubMed ID: 29159531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Morphological, Functional, and Biological Vascular Healing Response 6 Months After Drug-Eluting Stent Implantation: A Randomized Comparison of Three Drug-Eluting Stents.
    Nakata T; Fujii K; Fukunaga M; Shibuya M; Kawai K; Kawasaki D; Naito Y; Ohyanagi M; Masuyama T
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):350-7. PubMed ID: 26526816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Very early tissue coverage after drug-eluting stent implantation: an optical coherence tomography study.
    Takahara M; Kitahara H; Nishi T; Miura K; Miyayama T; Sugimoto K; Nakayama T; Fujimoto Y; Kobayashi Y
    Int J Cardiovasc Imaging; 2017 Jan; 33(1):25-30. PubMed ID: 27601229
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis.
    Jaguszewski M; Aloysius R; Wang W; Bezerra HG; Hill J; De Winter RJ; Karjalainen PP; Verheye S; Wijns W; Lüscher TF; Joner M; Costa M; Landmesser U
    JACC Cardiovasc Interv; 2017 Mar; 10(5):489-499. PubMed ID: 28279316
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Serial optical coherence tomography assessment of malapposed struts after everolimus-eluting stent implantation. A subanalysis from the HEAL-EES study.
    Ishida K; Otsuki S; Giacchi G; Ortega-Paz L; Shiratori Y; Freixa X; Martín-Yuste V; Masotti M; Sabaté M; Brugaletta S
    Cardiovasc Revasc Med; 2017; 18(1):47-52. PubMed ID: 27634493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography.
    Fujino Y; Attizzani GF; Bezerra HG; Wang W; Tahara S; Yamamoto H; Chamie D; Kanaya T; Mehanna E; Takagi K; Nakamura S; Costa MA
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1035-45. PubMed ID: 24156964
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early healing assessment with optical coherence tomography of everolimus-eluting stents with bioabsorbable polymer (synergy™) at 3 and 6 months after implantation.
    de la Torre Hernández JM; Tejedor P; Camarero TG; Duran JM; Lee DH; Monedero J; Laso FS; Calderón MA; Veiga G; Zueco J
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):E67-73. PubMed ID: 26526783
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of zotarolimus-eluting stent and everolimus-eluting stent for vascular healing response: serial 3-month and 12-month optical coherence tomography study.
    Kim SJ; Lee H; Cho JM; Park CB; Kim W; Kato K; Yonetsu T; Kim CJ; Jang IK
    Coron Artery Dis; 2013 Aug; 24(5):431-9. PubMed ID: 23722649
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study.
    Otsuki S; Brugaletta S; Sabaté M; Shiratori Y; Gomez-Monterrosas O; Scalone G; Romero-Villafañe S; Hernández-Enríquez M; Freixa X; Martín-Yuste V; Masotti M
    Cardiovasc Revasc Med; 2016 Jun; 17(4):241-7. PubMed ID: 27158001
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.
    Kim BK; Shin DH; Kim JS; Ko YG; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2015 Feb; 31(2):269-77. PubMed ID: 25345751
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optical coherence tomography findings after chronic total occlusion interventions: Insights from the "AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions" (ACE-CTO) study (NCT01012869).
    Sherbet DP; Christopoulos G; Karatasakis A; Danek BA; Kotsia A; Navara R; Michael TT; Roesle M; Rangan BV; Haagen D; Garcia S; Maniu C; Pershad A; Abdullah SM; Hastings JL; Kumbhani DJ; Luna M; Addo T; Banerjee S; Brilakis ES
    Cardiovasc Revasc Med; 2016; 17(7):444-449. PubMed ID: 27133499
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation.
    Kim BK; Shin DH; Kim JS; Ko YG; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2012 Dec; 28(8):1887-94. PubMed ID: 22447206
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography.
    Choi HH; Kim JS; Yoon DH; Hong KS; Kim TH; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2012 Mar; 28(3):491-7. PubMed ID: 21442265
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Neointimal tissue characterization after implantation of drug-eluting stents by optical coherence tomography: quantitative analysis of optical density.
    Nishino S; Sakuma M; Kanaya T; Nasuno T; Tokura M; Toyoda S; Abe S; Nakamura D; Tanaka K; Attizzani GF; Bezerra HG; Costa MA; Inoue T
    Int J Cardiovasc Imaging; 2019 Nov; 35(11):1971-1978. PubMed ID: 31218524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years.
    Onuma Y; Honda Y; Asano T; Shiomi H; Kozuma K; Ozaki Y; Namiki A; Yasuda S; Ueno T; Ando K; Furuya J; Hanaoka KI; Tanabe K; Okada K; Kitahara H; Ono M; Kusano H; Rapoza R; Simonton C; Popma JJ; Stone GW; Fitzgerald PJ; Serruys PW; Kimura T
    JACC Cardiovasc Interv; 2020 Jan; 13(1):116-127. PubMed ID: 31918929
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized Multicenter Trial Investigating Angiographic Outcomes of Hybrid Sirolimus-Eluting Stents With Biodegradable Polymer Compared With Everolimus-Eluting Stents With Durable Polymer in Chronic Total Occlusions: The PRISON IV Trial.
    Teeuwen K; van der Schaaf RJ; Adriaenssens T; Koolen JJ; Smits PC; Henriques JP; Vermeersch PH; Tjon Joe Gin RM; Schölzel BE; Kelder JC; Tijssen JG; Agostoni P; Suttorp MJ
    JACC Cardiovasc Interv; 2017 Jan; 10(2):133-143. PubMed ID: 28104206
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of neointimal coverage between durable-polymer everolimus-eluting stents and bioresorbable-polymer everolimus-eluting stents 1 year after implantation using high-resolution coronary angioscopy.
    Nojima Y; Adachi H; Ihara M; Kurimoto T; Okayama K; Sakata Y; Nanto S
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):204-209. PubMed ID: 30737973
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.