These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 3238948)

  • 21. Evaluation of a system using oral mucosal transudate for HIV-1 antibody screening and confirmatory testing. OraSure HIV Clinical Trials Group.
    Gallo D; George JR; Fitchen JH; Goldstein AS; Hindahl MS
    JAMA; 1997 Jan; 277(3):254-8. PubMed ID: 9005276
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The significance of repeat testing in Turkish blood donors screened with HBV, HCV and HIV immunoassays and the importance of S/CO ratios in the interpretation of HCV/HIV screening test results and as a determinant for further confirmatory testing.
    Acar A; Kemahli S; Altunay H; Kosan E; Oncul O; Gorenek L; Cavuslu S
    Transfus Med; 2010 Jun; 20(3):152-9. PubMed ID: 20059750
    [TBL] [Abstract][Full Text] [Related]  

  • 23. What do western blot indeterminate patterns for human immunodeficiency virus mean in EIA-negative blood donors?
    Genesca J; Shih JW; Jett BW; Hewlett IK; Epstein JS; Alter HJ
    Lancet; 1989 Oct; 2(8670):1023-5. PubMed ID: 2572749
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks.
    Otani MM; Salles NA; Barreto AM; Barreto CC; Chamone DF; Sabino EC
    Rev Panam Salud Publica; 2003; 13(2-3):172-5. PubMed ID: 12744793
    [TBL] [Abstract][Full Text] [Related]  

  • 25. IgA and IgM human immunodeficiency virus antibodies in weakly reactive or false-negative blood donors.
    Weiblen BJ; Schumacher RT; Garrett PE; Hoff R
    Transfusion; 1991 Jun; 31(5):397-400. PubMed ID: 2048177
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Screening tests for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus in blood donors: evaluation of two chemiluminescent immunoassay systems.
    Sommese L; Sabia C; Paolillo R; Parente D; Capuano M; Iannone C; Cavalca F; Schiano C; Vasco M; De Pascale MR; Casamassimi A; Napoli C
    Scand J Infect Dis; 2014 Sep; 46(9):660-4. PubMed ID: 25073538
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Prevalence of human immunodeficiency virus type 1 p24 antigen in U.S. blood donors--an assessment of the efficacy of testing in donor screening. The HIV-Antigen Study Group.
    Alter HJ; Epstein JS; Swenson SG; VanRaden MJ; Ward JW; Kaslow RA; Menitove JE; Klein HG; Sandler SG; Sayers MH
    N Engl J Med; 1990 Nov; 323(19):1312-7. PubMed ID: 2120589
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the human T-cell leukemia virus type I seropositivity of blood donors by the particle agglutination inhibition test.
    Kwon KW; Ikeda H; Yano M; Sekiguchi S
    Jpn J Cancer Res; 1989 Sep; 80(9):833-9. PubMed ID: 2513300
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Field evaluation of rapid HIV serologic tests for screening and confirming HIV-1 infection in Honduras.
    Stetler HC; Granade TC; Nunez CA; Meza R; Terrell S; Amador L; George JR
    AIDS; 1997 Mar; 11(3):369-75. PubMed ID: 9147429
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Pretransfusion screening tests for HIV and HTLV-I in donated blood].
    Okubo S
    Rinsho Byori; 1989 Jul; 37(7):762-7. PubMed ID: 2607646
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Screening for human immunodeficiency virus antibody in urine.
    Berrios DC; Avins AL; Haynes-Sanstad K; Eversley R; Woods WJ
    Arch Pathol Lab Med; 1995 Feb; 119(2):139-41. PubMed ID: 7848060
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of screening kits for the detection of anti-human immunodeficiency virus type 1 and 2 (HIV-1/2) antibodies.
    Chin LT; Yang BS; Chen JW; Yang CM; Chou CC; Li L; Hung CM; Tsai SJ; Lin KS
    Zhonghua Min Guo Wei Sheng Wu Ji Mian Yi Xue Za Zhi; 1995 Aug; 28(3):179-92. PubMed ID: 9774997
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Serologic and molecular typing of human T-lymphotropic virus among blood donors in Maputo City, Mozambique.
    Gudo ES; Abreu CM; Mussá T; Augusto Ado R; Otsuki K; Chambo E; Amade N; Tanuri A; Ferreira OC; Jani IV;
    Transfusion; 2009 Jun; 49(6):1146-50. PubMed ID: 19222818
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Gelatin particle agglutination assay as an auxiliary confirmation test for HIV-1 antibodies.
    McShine RL; de Vries AH; Das PC; Smit Sibinga CT
    Med Lab Sci; 1990 Oct; 47(4):359. PubMed ID: 2283941
    [No Abstract]   [Full Text] [Related]  

  • 35. Long-term follow-up of blood donors with indeterminate human immunodeficiency virus type 1 results on Western blot.
    Jackson JB; Hanson MR; Johnson GM; Spahlinger TG; Polesky HF; Bowman RJ
    Transfusion; 1995 Feb; 35(2):98-102. PubMed ID: 7825219
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Longitudinal follow-up of blood donors found to be reactive for antibody to human immunodeficiency virus (anti-HIV) by enzyme-linked immunoassay (EIA+) but negative by western blot (WB-).
    Nusbacher J; Naiman R
    Transfusion; 1989 May; 29(4):365-7. PubMed ID: 2655209
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reduced frequency of blood donors with false-positive HIV-1 and -2 antibody EIA reactivity after elution of low-affinity nonspecific natural antibodies.
    Bouillon M; Aubin E; Roberge C; Bazin R; Lemieux R
    Transfusion; 2002 Aug; 42(8):1046-52. PubMed ID: 12385417
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of a rapid microfiltration test for detection of HIV-1 antibody in serum.
    Wang SY; Lin TL; Chen HY; Horng CB
    Zhonghua Yi Xue Za Zhi (Taipei); 1995 Jun; 55(6):427-31. PubMed ID: 7634179
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Establishing a reentry procedure for human immunodeficiency virus screening-reactive donors in China.
    Li L; Xu T; Yang T; Zang L; Cheng W; Lin H; Zhu S; Zhao B; Duan R; Li C; Huang M; Liu Y; Ming C; Xu S; Wang C; Wu Y; Liu Z
    Transfusion; 2016 Jan; 56(1):195-202. PubMed ID: 26360920
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Efficacies of US Food and Drug Administration-licensed HIV-1-screening enzyme immunoassays for detecting antibodies to HIV-2.
    George JR; Rayfield MA; Phillips S; Heyward WL; Krebs JW; Odehouri K; Soudre R; De Cock KM; Schochetman G
    AIDS; 1990 Apr; 4(4):321-6. PubMed ID: 2350452
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.