These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 3239618)

  • 1. Chronic exercise-induced compartment pressure elevation measured with a miniaturized fluid pressure monitor. A laboratory and clinical study.
    Awbrey BJ; Sienkiewicz PS; Mankin HJ
    Am J Sports Med; 1988; 16(6):610-5. PubMed ID: 3239618
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of measurement of hand compartment pressures: a cadaveric study.
    Wong JC; Vosbikian MM; Dwyer JM; Ilyas AM
    J Hand Surg Am; 2015 Apr; 40(4):701-6. PubMed ID: 25648783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accurate compartment pressure measurement using the Intervenous Alarm Control (IVAC) Pump. Report of a technique.
    Uppal GS; Smith RC; Sherk HH; Mooar P
    J Orthop Trauma; 1992; 6(1):87-9. PubMed ID: 1556629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy in the measurement of compartment pressures: a comparison of three commonly used devices.
    Boody AR; Wongworawat MD
    J Bone Joint Surg Am; 2005 Nov; 87(11):2415-22. PubMed ID: 16264116
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra- and interobserver variability during in vitro validation of two novel methods for intra-abdominal pressure monitoring.
    De Potter TJ; Dits H; Malbrain ML
    Intensive Care Med; 2005 May; 31(5):747-51. PubMed ID: 15809871
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The reliability of measurement of tissue pressure in compartment syndrome.
    Hammerberg EM; Whitesides TE; Seiler JG
    J Orthop Trauma; 2012 Jan; 26(1):24-31; discussion 32. PubMed ID: 21918480
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation and experience with a simple continuous intra-abdominal pressure measurement technique in a multidisciplinary medical/surgical critical care unit.
    Zengerink I; McBeth PB; Zygun DA; Ranson K; Ball CG; Laupland KB; Widder S; Kirkpatrick AW
    J Trauma; 2008 May; 64(5):1159-64. PubMed ID: 18469635
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Compartmental pressure measurements: an experimental investigation using the slit catheter.
    Rorabeck CH; Castle GS; Hardie R; Logan J
    J Trauma; 1981 Jun; 21(6):446-9. PubMed ID: 7230297
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of three methods for measuring intracompartmental pressure in injured limbs of trauma patients.
    Collinge C; Kuper M
    J Orthop Trauma; 2010 Jun; 24(6):364-8. PubMed ID: 20502219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a modified piezoresistive technique and a water-capsule technique for direct and continuous measurement of intra-abdominal pressure in a porcine model.
    Schachtrupp A; Henzler D; Orfao S; Schaefer W; Schwab R; Becker P; Schumpelick V
    Crit Care Med; 2006 Mar; 34(3):745-50. PubMed ID: 16505660
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous intra-abdominal pressure measurement technique.
    Balogh Z; Jones F; D'Amours S; Parr M; Sugrue M
    Am J Surg; 2004 Dec; 188(6):679-84. PubMed ID: 15619483
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Baseline compartment pressure measurements in isolated lower extremity fractures without clinical compartment syndrome.
    Prayson MJ; Chen JL; Hampers D; Vogt M; Fenwick J; Meredick R
    J Trauma; 2006 May; 60(5):1037-40. PubMed ID: 16688067
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of intracompartmental pressure: a comparison of the slit catheter, side-ported needle, and simple needle.
    Moed BR; Thorderson PK
    J Bone Joint Surg Am; 1993 Feb; 75(2):231-5. PubMed ID: 8423183
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Compartment syndrome and shin splints of the lower leg.
    Gerow G; Matthews B; Jahn W; Gerow R
    J Manipulative Physiol Ther; 1993 May; 16(4):245-52. PubMed ID: 8340719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic pressure testing for chronic exertional compartment syndrome in the UK military population.
    Dharm-Datta S; Minden DF; Rosell PA; Hill PF; Mistlin A; Etherington J
    J R Army Med Corps; 2013 Jun; 159(2):114-8. PubMed ID: 23720594
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Instrumental muscle pressure measurement in acute and chronic compartment syndrome].
    Witschger PM; Wegmüller M
    Z Unfallchir Versicherungsmed; 1994 Apr; 87(1):45-51. PubMed ID: 8031635
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monitoring of intramuscular pressure.
    Matsen FA; Mayo KA; Sheridan GW; Krugmire RB
    Surgery; 1976 Jun; 79(6):702-9. PubMed ID: 1273755
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of compartment pressures in the hand and forearm.
    Lipschitz AH; Lifchez SD
    J Hand Surg Am; 2010 Nov; 35(11):1893-4. PubMed ID: 20870362
    [No Abstract]   [Full Text] [Related]  

  • 19. In vitro validation of a novel method for continuous intra-abdominal pressure monitoring.
    Malbrain ML; De laet I; Viaene D; Schoonheydt K; Dits H
    Intensive Care Med; 2008 Apr; 34(4):740-5. PubMed ID: 18075730
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Compartment pressure in the foot. Analysis of normal values and measurement technique.
    Dayton P; Goldman FD; Barton E
    J Am Podiatr Med Assoc; 1990 Oct; 80(10):521-5. PubMed ID: 2269919
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.