These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 3239821)

  • 1. Factors concerning the design and calibration of an amperometric enzyme electrode system for the flow injection analysis of cholesterol.
    Moody GJ; Sanghera GS; Thomas JD
    Analyst; 1988 Sep; 113(9):1419-22. PubMed ID: 3239821
    [No Abstract]   [Full Text] [Related]  

  • 2. Amperometric assays of total and free cholesterols in serum by the combined use of immobilized cholesterol esterase and cholesterol oxidase reactors and peroxidase electrode in a flow injection system.
    Yao T; Sato M; Kobayashi Y; Wasa T
    Anal Biochem; 1985 Sep; 149(2):387-91. PubMed ID: 3000216
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator.
    Nakaminami T; Ito S; Kuwabata S; Yoneyama H
    Anal Chem; 1999 Mar; 71(5):1068-76. PubMed ID: 10079764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cholesterol Oxidase Functionalised Polyaniline/Carbon Nanotube Hybrids for an Amperometric Biosensor.
    Shukla SK; Turner AP; Tiwari A
    J Nanosci Nanotechnol; 2015 May; 15(5):3373-7. PubMed ID: 26504954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selective determination of cholesterol based on cholesterol oxidase-alkaline phosphatase bienzyme electrode.
    Zhang H; Liu R; Zheng J
    Analyst; 2012 Nov; 137(22):5363-7. PubMed ID: 23019566
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Usefulness of magnetically-controlled MNPs-enzymes microreactors for the fluorimetric determination of total cholesterol in serum.
    Román-Pizarro V; Ramírez-Gutiérrez M; Gómez-Hens A; Fernández-Romero JM
    Talanta; 2020 Feb; 208():120426. PubMed ID: 31816686
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples.
    Saxena U; Chakraborty M; Goswami P
    Biosens Bioelectron; 2011 Feb; 26(6):3037-43. PubMed ID: 21195602
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination.
    Manjunatha R; Shivappa Suresh G; Melo JS; D'Souza SF; Venkatesha TV
    Talanta; 2012 Sep; 99():302-9. PubMed ID: 22967556
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and aniline in sulphuric Acid for the determination of cholesterol in serum.
    Muhammet SM; Cete S; Arslan F; Yaşar A
    Artif Cells Blood Substit Immobil Biotechnol; 2009; 37(6):273-8. PubMed ID: 19922167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples.
    Basu AK; Chattopadhyay P; Roychoudhuri U; Chakraborty R
    Bioelectrochemistry; 2007 May; 70(2):375-9. PubMed ID: 16814618
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitive amperometric biosensors for detection of glucose and cholesterol using a platinum/reduced graphene oxide/poly(3-aminobenzoic acid) film-modified screen-printed carbon electrode.
    Phetsang S; Jakmunee J; Mungkornasawakul P; Laocharoensuk R; Ounnunkad K
    Bioelectrochemistry; 2019 Jun; 127():125-135. PubMed ID: 30818262
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Amperometric cholesterol biosensor based on in situ reconstituted cholesterol oxidase on an immobilized monolayer of flavin adenine dinucleotide cofactor.
    Vidal JC; Espuelas J; Castillo JR
    Anal Biochem; 2004 Oct; 333(1):88-98. PubMed ID: 15351284
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a novel biosensor based on a conducting polymer.
    Soylemez S; Ekiz Kanik F; Ileri M; Hacioglu SO; Toppare L
    Talanta; 2014 Jan; 118():84-9. PubMed ID: 24274273
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous co-immobilization of three enzymes onto a modified glassy carbon electrode to fabricate a high-performance amperometric biosensor for determination of total cholesterol.
    Rashidi K; Mahmoudi M; Mohammadi G; Zangeneh MM; Korani S; Goicoechea HC; Gu HW; Jalalvand AR
    Int J Biol Macromol; 2018 Dec; 120(Pt A):587-595. PubMed ID: 30170050
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.
    Zhao C; Wan L; Jiang L; Wang Q; Jiao K
    Anal Biochem; 2008 Dec; 383(1):25-30. PubMed ID: 18783720
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor.
    Wisitsoraat A; Sritongkham P; Karuwan C; Phokharatkul D; Maturos T; Tuantranont A
    Biosens Bioelectron; 2010 Dec; 26(4):1514-20. PubMed ID: 20727731
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor.
    Singh S; Singhal R; Malhotra BD
    Anal Chim Acta; 2007 Jan; 582(2):335-43. PubMed ID: 17386511
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel paper-based cholesterol biosensor using graphene/polyvinylpyrrolidone/polyaniline nanocomposite.
    Ruecha N; Rangkupan R; Rodthongkum N; Chailapakul O
    Biosens Bioelectron; 2014 Feb; 52():13-9. PubMed ID: 24013212
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film.
    Tan X; Li M; Cai P; Luo L; Zou X
    Anal Biochem; 2005 Feb; 337(1):111-20. PubMed ID: 15649383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol.
    Vidal JC; Garcia-Ruiz E; Espuelas J; Aramendia T; Castillo JR
    Anal Bioanal Chem; 2003 Sep; 377(2):273-80. PubMed ID: 12923606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.