BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 32402439)

  • 1. Surface analysis and corrosion behavior of pure titanium under fluoride exposure.
    Chen WQ; Zhang SM; Qiu J
    J Prosthet Dent; 2020 Aug; 124(2):239.e1-239.e8. PubMed ID: 32402439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The potential influence of high uric acid exposure on surface and corrosion susceptibility of pure titanium.
    Liu Y; Zhang WS; Tang ZH; Zhang SM; Qiu J
    J Mater Sci Mater Med; 2022 May; 33(6):44. PubMed ID: 35575837
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium.
    Huang HH
    Biomaterials; 2002 Jan; 23(1):59-63. PubMed ID: 11762855
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
    Zhu JF; Gan K; Du TF; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
    [No Abstract]   [Full Text] [Related]  

  • 5. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride.
    Takemoto S; Hattori M; Yoshinari M; Kawada E; Asami K; Oda Y
    Dent Mater J; 2004 Sep; 23(3):379-86. PubMed ID: 15510869
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osteoclast-mediated biocorrosion of pure titanium in an inflammatory microenvironment.
    Yu XY; Zhu WQ; Chen W; Chen WQ; Zhang SM; Qiu J
    Mater Sci Eng C Mater Biol Appl; 2021 Feb; 119():111610. PubMed ID: 33321654
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study.
    Souza JC; Barbosa SL; Ariza EA; Henriques M; Teughels W; Ponthiaux P; Celis JP; Rocha LA
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():384-93. PubMed ID: 25492211
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrochemical evaluation of the hydrogen peroxide- and fluoride-induced corrosive property and its recovery on the titanium surface.
    Furiya-Sato S; Fukushima A; Mayanagi G; Sasaki K; Takahashi N
    J Prosthodont Res; 2020 Jul; 64(3):307-312. PubMed ID: 31629684
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Effect of fluoride ion on corrosion of two dental titanium alloys].
    Cao BW; Chen L
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Streptococcus mutans colonization on titanium surfaces treated with various fluoride-containing preventive solutions].
    Stájer A; Urban E; Mihalik E; Rakonczay Z; Nagy E; Fazekas A; Turzó K; Radnai M; Nagy K
    Fogorv Sz; 2009 Jun; 102(3):117-22. PubMed ID: 19618781
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide.
    Peñarrieta-Juanito G; Sordi MB; Henriques B; Dotto MER; Teughels W; Silva FS; Magini RS; Souza JCM
    J Periodontal Res; 2019 Feb; 54(1):46-52. PubMed ID: 30368813
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The effect of fluoride on electrochemical corrosion of the dental pure titanium before and after adhesion of Streptococcus mutans].
    Geng L; Qiao GY; Gu KK
    Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):150-6. PubMed ID: 27329875
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of a fluoridated medium with different pHs on commercially pure titanium-based implants.
    Sartori R; Correa CB; Marcantonio E; Vaz LG
    J Prosthodont; 2009 Feb; 18(2):130-4. PubMed ID: 19054308
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of plasma nitriding and titanium nitride coating on the corrosion resistance of titanium.
    Wang X; Bai S; Li F; Li D; Zhang J; Tian M; Zhang Q; Tong Y; Zhang Z; Wang G; Guo T; Ma C
    J Prosthet Dent; 2016 Sep; 116(3):450-6. PubMed ID: 27061632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corrosion behavior of pure titanium in the presence of Actinomyces naeslundii.
    Zhang SM; Qiu J; Tian F; Guo XK; Zhang FQ; Huang QF
    J Mater Sci Mater Med; 2013 May; 24(5):1229-37. PubMed ID: 23430335
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SEM observations on stress corrosion cracking of commercially pure titanium in a topical fluoride solution.
    Könönen MH; Lavonius ET; Kivilahti JK
    Dent Mater; 1995 Jul; 11(4):269-72. PubMed ID: 8621050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
    Nakagawa M; Matsuya S; Udoh K
    Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use.
    Nakagawa M; Matsuya S; Shiraishi T; Ohta M
    J Dent Res; 1999 Sep; 78(9):1568-72. PubMed ID: 10512392
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corrosive effects of fluoride on titanium under artificial biofilm.
    Fukushima A; Mayanagi G; Sasaki K; Takahashi N
    J Prosthodont Res; 2018 Jan; 62(1):104-109. PubMed ID: 28916465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.