These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 32406652)

  • 21. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    Int J Oral Maxillofac Implants; 2013; 28(6):1619-28. PubMed ID: 24278931
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations.
    Maniewicz S; Badoud I; Herrmann FR; Chebib N; Ammann P; Schimmel M; Müller F; Srinivasan M
    Clin Oral Implants Res; 2020 Apr; 31(4):315-327. PubMed ID: 31876004
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Stud vs Bar Attachments for Maxillary Four-Implant-Supported Overdentures: 3- to 9-year Results from a Retrospective Study.
    Lian M; Zhao K; Wang F; Huang W; Zhang X; Wu Y
    Int J Oral Maxillofac Implants; 2019; 34(4):936–946. PubMed ID: 30934037
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments - an in vitro study.
    Srinivasan M; Schimmel M; Badoud I; Ammann P; Herrmann FR; Müller F
    Clin Oral Implants Res; 2016 May; 27(5):604-11. PubMed ID: 26085188
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces.
    Yang TC; Maeda Y; Gonda T; Kotecha S
    Clin Oral Implants Res; 2011 Nov; 22(11):1315-9. PubMed ID: 21426402
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical behavior of 2-implant- and single-implant-retained mandibular overdentures with conventional or mini implants.
    Pisani MX; Presotto AGC; Mesquita MF; Barão VAR; Kemmoku DT; Del Bel Cury AA
    J Prosthet Dent; 2018 Sep; 120(3):421-430. PubMed ID: 29703669
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs.
    Alsabeeha N; Atieh M; Swain MV; Payne AG
    Int J Prosthodont; 2010; 23(2):160-6. PubMed ID: 20305857
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.
    ELsyad MA; Errabti HM; Mustafa AZ
    J Prosthodont; 2016 Dec; 25(8):656-664. PubMed ID: 26376338
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Stress analysis of mandibular two-implant overdenture with different attachment systems.
    Takeshita S; Kanazawa M; Minakuchi S
    Dent Mater J; 2011; 30(6):928-34. PubMed ID: 22123019
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Three-dimensional finite element analysis of four-implants supported mandibular overdentures using two different attachments].
    Jiang MY; Wen J; Xu SS; Liu TS; Sun HQ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):41-45. PubMed ID: 30630258
    [No Abstract]   [Full Text] [Related]  

  • 31. Effects of Low-Profile Stud Attachment Configurations on Stress Distribution Characteristics of Implant-Retained Overdentures.
    Tokar E; Uludag B
    Int J Oral Maxillofac Implants; 2018; 33(4):754-763. PubMed ID: 30024990
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical denture base deformation with different attachments used to stabilize implant overdentures: A crossover study.
    ELsyad MA; Fathe Mahanna F; Samir Khirallah A; Ali Habib A
    Clin Oral Implants Res; 2020 Feb; 31(2):162-172. PubMed ID: 31654580
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Crestal strain of two-implant mandibular overdentures with implants placed at different positions: An in vitro 3D printed simulation study.
    Patil PG; Seow LL; Uddanwadikar R; Pau A; Ukey PD
    J Prosthet Dent; 2024 Feb; 131(2):281.e1-281.e9. PubMed ID: 37985307
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.
    Osman RB; Elkhadem AH; Ma S; Swain MV
    Int J Oral Maxillofac Implants; 2013; 28(5):e198-208. PubMed ID: 24066336
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Impact of implants number and attachment type on the peri-implant stresses and retention of palateless implant-retained overdenture.
    Hegazy SA; El Mekawy N; Emera RMK
    Indian J Dent Res; 2020; 31(3):414-419. PubMed ID: 32769276
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of retention and stability of two implant-retained overdentures based on implant location.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    J Prosthet Dent; 2014 Sep; 112(3):515-21. PubMed ID: 24819528
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of Cyclic Dislodging on the Retention of Two Attachment Systems for Implant-supported Overdentures: An In Vitro Study.
    Tohme H; Makzoume J; Boulos P; Fakhoury J; Yared C; Salameh Z; Daou M
    J Contemp Dent Pract; 2018 Nov; 19(11):1386-1392. PubMed ID: 30602646
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of different numbers of mini-dental implants on alveolar ridge strain distribution under mandibular implant-retained overdentures.
    Warin P; Rungsiyakull P; Rungsiyakull C; Khongkhunthian P
    J Prosthodont Res; 2018 Jan; 62(1):35-43. PubMed ID: 28625664
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of LOCATOR attachments with different retentive forces on the stability of 2-implant-retained mandibular overdenture.
    Liu W; Zhang X; Qing H; Wang J
    J Prosthet Dent; 2020 Aug; 124(2):224-229. PubMed ID: 31780109
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis.
    Liu J; Pan S; Dong J; Mo Z; Fan Y; Feng H
    J Dent; 2013 Mar; 41(3):241-9. PubMed ID: 23160036
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.