154 related articles for article (PubMed ID: 32413872)
1. Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport.
LaBella A; Zhao W; Lubinsky R; Goldan AH
Phys Med Biol; 2020 Sep; 65(18):18LT01. PubMed ID: 32413872
[TBL] [Abstract][Full Text] [Related]
2. High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.
LaBella A; Cao X; Petersen E; Lubinsky R; Biegon A; Zhao W; Goldan AH
J Nucl Med; 2020 Oct; 61(10):1528-1533. PubMed ID: 32111684
[TBL] [Abstract][Full Text] [Related]
3. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT.
Ito M; Lee JS; Park MJ; Sim KS; Hong SJ
Phys Med Biol; 2010 Jul; 55(13):3827-41. PubMed ID: 20551503
[TBL] [Abstract][Full Text] [Related]
4. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
Zeng X; LaBella A; Wang Z; Li Y; Tan W; Goldan AH
Med Phys; 2024 Jun; 51(6):4044-4055. PubMed ID: 38682574
[TBL] [Abstract][Full Text] [Related]
5. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
Seo M; Park H; Lee S; Ko GB; Lee JS
Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
[TBL] [Abstract][Full Text] [Related]
6. An edge-readout, multilayer detector for positron emission tomography.
Li X; Ruiz-Gonzalez M; Furenlid LR
Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
[TBL] [Abstract][Full Text] [Related]
7. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
[TBL] [Abstract][Full Text] [Related]
8. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
Son JW; Lee MS; Lee JS
Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
[TBL] [Abstract][Full Text] [Related]
9. Development of a dual-ended readout detector with segmented crystal bars made using a subsurface laser engraving technique.
Mohammadi A; Yoshida E; Nishikido F; Nitta M; Shimizu K; Sakai T; Yamaya T
Phys Med Biol; 2018 Jan; 63(2):025019. PubMed ID: 29176052
[TBL] [Abstract][Full Text] [Related]
10. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.
Ren S; Yang Y; Cherry SR
Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406
[TBL] [Abstract][Full Text] [Related]
11. Performance of long rectangular semi-monolithic scintillator PET detectors.
Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
[TBL] [Abstract][Full Text] [Related]
12. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
Habte F; Foudray AM; Olcott PD; Levin CS
Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
[TBL] [Abstract][Full Text] [Related]
13. CHERENCUBE: concept definition and implementation challenges of a Cherenkov-based detector block for PET.
Somlai-Schweiger I; Ziegler SI
Med Phys; 2015 Apr; 42(4):1825-35. PubMed ID: 25832073
[TBL] [Abstract][Full Text] [Related]
14. A layered single-side readout depth of interaction time-of-flight-PET detector.
Bläckberg L; Sajedi S; El Fakhri G; Sabet H
Phys Med Biol; 2021 Feb; 66(4):045025. PubMed ID: 33570050
[TBL] [Abstract][Full Text] [Related]
15. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
Zhang Y; Yan H; Baghaei H; Wong WH
Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144
[TBL] [Abstract][Full Text] [Related]
16. Simulation study of spatial resolution and sensitivity for the tapered depth of interaction PET detectors for small animal imaging.
St James S; Yang Y; Bowen SL; Qi J; Cherry SR
Phys Med Biol; 2010 Jan; 55(2):N63-74. PubMed ID: 20023331
[TBL] [Abstract][Full Text] [Related]
17. Sub-2 mm depth of interaction localization in PET detectors with prismatoid light guide arrays and single-ended readout using convolutional neural networks.
LaBella A; Cao X; Zeng X; Zhao W; Goldan AH
Med Phys; 2021 Mar; 48(3):1019-1025. PubMed ID: 33305482
[TBL] [Abstract][Full Text] [Related]
18. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.
Shao Y; Yao R; Ma T
Med Phys; 2008 Dec; 35(12):5829-40. PubMed ID: 19175139
[TBL] [Abstract][Full Text] [Related]
19. Development of dual-ended depth-of-interaction detectors using laser-induced crystals for small animal PET systems.
Mohammadi A; Inadama N; Nishikido F; Yamaya T
Phys Med Biol; 2021 Sep; 66(17):. PubMed ID: 34325418
[TBL] [Abstract][Full Text] [Related]
20. Design study of a brain-dedicated time-of-flight PET system with a hemispherical detector arrangement.
Takyu S; Ahmed AM; Yoshida E; Tashima H; Kumagai M; Yamashita T; Yamaya T
Phys Med Biol; 2020 Feb; 65(3):035012. PubMed ID: 31855854
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]