BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

670 related articles for article (PubMed ID: 32415552)

  • 21. Generation of PET Attenuation Map for Whole-Body Time-of-Flight
    Hwang D; Kang SK; Kim KY; Seo S; Paeng JC; Lee DS; Lee JS
    J Nucl Med; 2019 Aug; 60(8):1183-1189. PubMed ID: 30683763
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantitative Evaluation of 2 Scatter-Correction Techniques for
    Teuho J; Saunavaara V; Tolvanen T; Tuokkola T; Karlsson A; Tuisku J; Teräs M
    J Nucl Med; 2017 Oct; 58(10):1691-1698. PubMed ID: 28336781
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Attenuation correction and truncation completion for breast PET/MR imaging using deep learning.
    Li X; Johnson JM; Strigel RM; Bancroft LCH; Hurley SA; Estakhraji SIZ; Kumar M; Fowler AM; McMillan AB
    Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38252969
    [No Abstract]   [Full Text] [Related]  

  • 24. Evaluation of a 2D UNet-Based Attenuation Correction Methodology for PET/MR Brain Studies.
    Presotto L; Bettinardi V; Bagnalasta M; Scifo P; Savi A; Vanoli EG; Fallanca F; Picchio M; Perani D; Gianolli L; De Bernardi E
    J Digit Imaging; 2022 Jun; 35(3):432-445. PubMed ID: 35091873
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.
    Leynes AP; Yang J; Wiesinger F; Kaushik SS; Shanbhag DD; Seo Y; Hope TA; Larson PEZ
    J Nucl Med; 2018 May; 59(5):852-858. PubMed ID: 29084824
    [TBL] [Abstract][Full Text] [Related]  

  • 26. MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers.
    Arabi H; Zaidi H
    Magn Reson Med; 2022 Feb; 87(2):686-701. PubMed ID: 34480771
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Clinical assessment of MR-guided 3-class and 4-class attenuation correction in PET/MR.
    Arabi H; Rager O; Alem A; Varoquaux A; Becker M; Zaidi H
    Mol Imaging Biol; 2015 Apr; 17(2):264-76. PubMed ID: 25096328
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A deep learning approach for
    Liu F; Jang H; Kijowski R; Zhao G; Bradshaw T; McMillan AB
    EJNMMI Phys; 2018 Nov; 5(1):24. PubMed ID: 30417316
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data.
    Lu Y; Fontaine K; Mulnix T; Onofrey JA; Ren S; Panin V; Jones J; Casey ME; Barnett R; Kench P; Fulton R; Carson RE; Liu C
    J Nucl Med; 2018 Sep; 59(9):1480-1486. PubMed ID: 29439015
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction.
    Torrado-Carvajal A; Vera-Olmos J; Izquierdo-Garcia D; Catalano OA; Morales MA; Margolin J; Soricelli A; Salvatore M; Malpica N; Catana C
    J Nucl Med; 2019 Mar; 60(3):429-435. PubMed ID: 30166357
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of Atlas-Based Attenuation Correction for Integrated PET/MR in Human Brain: Application of a Head Atlas and Comparison to True CT-Based Attenuation Correction.
    Sekine T; Buck A; Delso G; Ter Voert EE; Huellner M; Veit-Haibach P; Warnock G
    J Nucl Med; 2016 Feb; 57(2):215-20. PubMed ID: 26493207
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Systematic Comparison of the Performance of Integrated Whole-Body PET/MR Imaging to Conventional PET/CT for ¹⁸F-FDG Brain Imaging in Patients Examined for Suspected Dementia.
    Hitz S; Habekost C; Fürst S; Delso G; Förster S; Ziegler S; Nekolla SG; Souvatzoglou M; Beer AJ; Grimmer T; Eiber M; Schwaiger M; Drzezga A
    J Nucl Med; 2014 Jun; 55(6):923-31. PubMed ID: 24833495
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessment of deep learning-based PET attenuation correction frameworks in the sinogram domain.
    Arabi H; Zaidi H
    Phys Med Biol; 2021 Jul; 66(14):. PubMed ID: 34167094
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of deep learning-based emission-only attenuation correction methods for positron emission tomography.
    Hwang D; Kang SK; Kim KY; Choi H; Lee JS
    Eur J Nucl Med Mol Imaging; 2022 May; 49(6):1833-1842. PubMed ID: 34882262
    [TBL] [Abstract][Full Text] [Related]  

  • 35. CT-less Direct Correction of Attenuation and Scatter in the Image Space Using Deep Learning for Whole-Body FDG PET: Potential Benefits and Pitfalls.
    Yang J; Sohn JH; Behr SC; Gullberg GT; Seo Y
    Radiol Artif Intell; 2021 Mar; 3(2):e200137. PubMed ID: 33937860
    [TBL] [Abstract][Full Text] [Related]  

  • 36. CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET.
    Visvikis D; Costa DC; Croasdale I; Lonn AH; Bomanji J; Gacinovic S; Ell PJ
    Eur J Nucl Med Mol Imaging; 2003 Mar; 30(3):344-53. PubMed ID: 12634961
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comprehensive Oncologic Imaging in Infants and Preschool Children With Substantially Reduced Radiation Exposure Using Combined Simultaneous ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance Imaging: A Direct Comparison to ¹⁸F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography.
    Gatidis S; Schmidt H; Gücke B; Bezrukov I; Seitz G; Ebinger M; Reimold M; Pfannenberg CA; Nikolaou K; Schwenzer NF; Schäfer JF
    Invest Radiol; 2016 Jan; 51(1):7-14. PubMed ID: 26309185
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging.
    Pozaruk A; Pawar K; Li S; Carey A; Cheng J; Sudarshan VP; Cholewa M; Grummet J; Chen Z; Egan G
    Eur J Nucl Med Mol Imaging; 2021 Jan; 48(1):9-20. PubMed ID: 32394162
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Direct attenuation correction of brain PET images using only emission data via a deep convolutional encoder-decoder (Deep-DAC).
    Shiri I; Ghafarian P; Geramifar P; Leung KH; Ghelichoghli M; Oveisi M; Rahmim A; Ay MR
    Eur Radiol; 2019 Dec; 29(12):6867-6879. PubMed ID: 31227879
    [TBL] [Abstract][Full Text] [Related]  

  • 40. PET scatter estimation using deep learning U-Net architecture.
    Laurent B; Bousse A; Merlin T; Nekolla S; Visvikis D
    Phys Med Biol; 2023 Mar; 68(6):. PubMed ID: 36240745
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 34.