These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 32421087)

  • 1. Event-Driven ECG Sensor in Healthcare Devices for Data Transfer Optimization.
    Ben-Romdhane M; Maalej A; Tlili M; Rebai C; Rivet F; Dallet D
    Arab J Sci Eng; 2020; 45(8):6361-6387. PubMed ID: 32421087
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the wavelet-based compressibility of continuous-time sampled ECG signal for e-health applications.
    Maalej A; Ben-Romdhane M; Tlili M; Rivet F; Dallet D; Rebai C
    Measurement (Lond); 2020 Nov; 164():108031. PubMed ID: 32565605
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Power Efficiency Comparison of Event-Driven and Fixed-Rate Signal Conversion and Compression for Biomedical Applications.
    Van Assche J; Gielen G
    IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):746-756. PubMed ID: 32746356
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation Detector Front-End Readout Chip with Nonbinary Successive Approximation Register Analog-to-Digital Converter for Wearable Healthcare Monitoring Applications.
    Kuo HL; Chen SL
    Micromachines (Basel); 2024 Jan; 15(1):. PubMed ID: 38258262
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 14-Bit Hybrid Analog-to-Digital Converter for Infrared Focal Plane Array Digital Readout Integrated Circuit.
    Hu D; Yao L; Chen N; Zhang J; Zhong S; Mao W; Zhu F; Zhang J
    Sensors (Basel); 2024 Jun; 24(11):. PubMed ID: 38894443
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A 10-Bit 400-KS/s Low Noise Asynchronous SAR ADC with Dual-Domain Comparator for Input-Referred Noise Reduction.
    Lee SH; Lee WY
    Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015841
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 62.2dB SNDR Event-Driven Level-Crossing ADC with SAR-Assisted Delay Compensation Loop for Time-Sparse Biomedical Signal Acquisition.
    Li M; Huo Y; Song S; Qu W; Ye L; Zhao M; Tan Z
    IEEE Trans Biomed Circuits Syst; 2024 Jul; PP():. PubMed ID: 38963740
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.
    Kim JH; Lee JH; Cho JH
    Technol Health Care; 2017 Jul; 25(S1):83-92. PubMed ID: 28582895
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Fast Multiple Sampling Method for Low-Noise CMOS Image Sensors With Column-Parallel 12-bit SAR ADCs.
    Kim MK; Hong SK; Kwon OK
    Sensors (Basel); 2015 Dec; 16(1):. PubMed ID: 26712765
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.
    Al-Busaidi AM; Khriji L; Touati F; Rasid MF; Mnaouer AB
    J Med Syst; 2017 Sep; 41(10):166. PubMed ID: 28900815
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adaptive Resolution ADC Array for an Implantable Neural Sensor.
    O'Driscoll S; Shenoy KV; Meng TH
    IEEE Trans Biomed Circuits Syst; 2011 Apr; 5(2):120-30. PubMed ID: 23851200
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Second-Order Level-Crossing Sampling Analog to Digital Converter for Electrocardiogram Delineation and Premature Ventricular Contraction Detection.
    Tang X; Renteria-Pinon M; Tang W
    IEEE Trans Biomed Circuits Syst; 2023 Dec; 17(6):1342-1354. PubMed ID: 37463086
    [TBL] [Abstract][Full Text] [Related]  

  • 13. ECG signal compression using combined modified discrete cosine and discrete wavelet transforms.
    Ahmed SM; Al-Ajlouni AF; Abo-Zahhad M; Harb B
    J Med Eng Technol; 2009; 33(1):1-8. PubMed ID: 19116848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. ECG data compression using optimal non-orthogonal wavelet transform.
    Ahmed SM; Al-Shrouf A; Abo-Zahhad M
    Med Eng Phys; 2000 Jan; 22(1):39-46. PubMed ID: 10817947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An ECG signal compressor based on the selection of optimal threshold levels of discrete wavelet transform coefficients.
    Al-Ajlouni AF; Abo-Zahhad M; Ahmed SM; Schilling RJ
    J Med Eng Technol; 2008; 32(6):425-33. PubMed ID: 19005960
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A hybrid ECG compression algorithm based on singular value decomposition and discrete wavelet transform.
    Ahmed SM; Al-Zoubi Q; Abo-Zahhad M
    J Med Eng Technol; 2007; 31(1):54-61. PubMed ID: 17365427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 1.33 μW 8.02-ENOB 100 kS/s successive approximation ADC with supply reduction technique for implantable retinal prosthesis.
    Tang H; Sun ZC; Chew KW; Siek L
    IEEE Trans Biomed Circuits Syst; 2014 Dec; 8(6):844-56. PubMed ID: 25608284
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of Level-Crossing ADCs for Event-Driven ECG Classification.
    Saeed M; Wang Q; Martens O; Larras B; Frappe A; Cardiff B; John D
    IEEE Trans Biomed Circuits Syst; 2021 Dec; 15(6):1129-1139. PubMed ID: 34919520
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A 13-bit Noise Shaping SAR-ADC with Dual-Polarity Digital Calibration.
    Park H; Ghovanloo M
    Analog Integr Circuits Signal Process; 2013 Jun; 75(3):459-465. PubMed ID: 23682207
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Design of 10-Bit Asynchronous SAR ADC with an On-Chip Bandgap Reference Voltage Generator.
    Verma D; Shehzad K; Kim SJ; Pu YG; Yoo SS; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35891072
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.