These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
185 related articles for article (PubMed ID: 32428875)
41. Robust heart rate estimation using wrist-based PPG signals in the presence of intense physical activities. Chengzhi Zong ; Jafari R Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():8078-82. PubMed ID: 26738168 [TBL] [Abstract][Full Text] [Related]
42. An EEMD-PCA approach to extract heart rate, respiratory rate and respiratory activity from PPG signal. Motin MA; Karmakar CK; Palaniswami M Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3817-3820. PubMed ID: 28269118 [TBL] [Abstract][Full Text] [Related]
43. A motion-tolerant approach for monitoring SpO Fan F; Yan Y; Tang Y; Zhang H Comput Biol Med; 2017 Dec; 91():291-305. PubMed ID: 29102826 [TBL] [Abstract][Full Text] [Related]
44. Detection of respiratory arousals using photoplethysmography (PPG) signal in sleep apnea patients. Karmakar C; Khandoker A; Penzel T; Schöbel C; Palaniswami M IEEE J Biomed Health Inform; 2014 May; 18(3):1065-73. PubMed ID: 24108482 [TBL] [Abstract][Full Text] [Related]
45. Detection of atrial fibrillation using a wrist-worn device. Sološenko A; Petrėnas A; Paliakaitė B; Sörnmo L; Marozas V Physiol Meas; 2019 Feb; 40(2):025003. PubMed ID: 30695758 [TBL] [Abstract][Full Text] [Related]
46. Finger and forehead PPG signal comparison for respiratory rate estimation. Hernando A; Peláez-Coca MD; Lozano MT; Lázaro J; Gil E Physiol Meas; 2019 Sep; 40(9):095007. PubMed ID: 31422948 [TBL] [Abstract][Full Text] [Related]
47. Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation. Wójcikowski M; Pankiewicz B Sensors (Basel); 2020 Mar; 20(6):. PubMed ID: 32210210 [TBL] [Abstract][Full Text] [Related]
48. Multi-Headed Conv-LSTM Network for Heart Rate Estimation during Daily Living Activities. Wilkosz M; Szczęsna A Sensors (Basel); 2021 Jul; 21(15):. PubMed ID: 34372447 [TBL] [Abstract][Full Text] [Related]
49. Cross time-frequency analysis for combining information of several sources: application to estimation of spontaneous respiratory rate from photoplethysmography. Peláez-Coca MD; Orini M; Lázaro J; Bailón R; Gil E Comput Math Methods Med; 2013; 2013():631978. PubMed ID: 24363777 [TBL] [Abstract][Full Text] [Related]
51. The Accuracy of Wrist-Worn Photoplethysmogram-Measured Heart and Respiratory Rates in Abdominal Surgery Patients: Observational Prospective Clinical Validation Study. van der Stam JA; Mestrom EHJ; Scheerhoorn J; Jacobs FENB; Nienhuijs S; Boer AK; van Riel NAW; de Morree HM; Bonomi AG; Scharnhorst V; Bouwman RA JMIR Perioper Med; 2023 Feb; 6():e40474. PubMed ID: 36804173 [TBL] [Abstract][Full Text] [Related]
52. Assessing the Quality of Heart Rate Variability Estimated from Wrist and Finger PPG: A Novel Approach Based on Cross-Mapping Method. Nardelli M; Vanello N; Galperti G; Greco A; Scilingo EP Sensors (Basel); 2020 Jun; 20(11):. PubMed ID: 32498403 [TBL] [Abstract][Full Text] [Related]
53. A wrist worn SpO2 monitor with custom finger probe for motion artifact removal. Preejith SP; Ravindran AS; Hajare R; Joseph J; Sivaprakasam M Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5777-5780. PubMed ID: 28269567 [TBL] [Abstract][Full Text] [Related]
54. PPGnet: Deep Network for Device Independent Heart Rate Estimation from Photoplethysmogram. Shyam A; Ravichandran V; Preejith SP; Joseph J; Sivaprakasam M Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1899-1902. PubMed ID: 31946269 [TBL] [Abstract][Full Text] [Related]
55. Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor. Huang N; Zhou M; Bian D; Mehta P; Shah M; Rajput KS; Selvaraj N Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7470-7475. PubMed ID: 34892821 [TBL] [Abstract][Full Text] [Related]
56. Robust Heart Rate Monitoring for Quasi-Periodic Motions by Wrist-Type PPG Signals. He W; Ye Y; Lu L; Cheng Y; Li Y; Wang Z IEEE J Biomed Health Inform; 2020 Mar; 24(3):636-648. PubMed ID: 31021779 [TBL] [Abstract][Full Text] [Related]
57. Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation. Harju J; Tarniceriu A; Parak J; Vehkaoja A; Yli-Hankala A; Korhonen I Physiol Meas; 2018 Jun; 39(6):065007. PubMed ID: 29856730 [TBL] [Abstract][Full Text] [Related]
58. Estimation of respiratory rates based on photoplethysmographic measurements at the sternum. Chreiteh SS; Belhage B; Hoppe K; Branebjerg J; Haahr R; Duun S; Thomsen EV Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6570-3. PubMed ID: 26737798 [TBL] [Abstract][Full Text] [Related]
59. Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction. Zhang Z IEEE Trans Biomed Eng; 2015 Aug; 62(8):1902-10. PubMed ID: 26186747 [TBL] [Abstract][Full Text] [Related]
60. A Deep Transfer Learning Approach for Sleep Stage Classification and Sleep Apnea Detection Using Wrist-Worn Consumer Sleep Technologies. Olsen M; Zeitzer JM; Nakase-Richardson R; Musgrave VH; Sorensen HBD; Mignot E; Jennum PJ IEEE Trans Biomed Eng; 2024 Aug; 71(8):2506-2517. PubMed ID: 38498753 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]