These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 32440943)

  • 1. Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.
    Elbatran AI; Li A; Gallagher MM; Kaba R; Norman M; Behr ER; Sohal M; Bajpai A; Zuberi Z; Saba MM
    J Interv Card Electrophysiol; 2021 Apr; 60(3):543-553. PubMed ID: 32440943
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial clinical results with the ThermoCool® SmartTouch® Surround Flow catheter.
    Gonna H; Domenichini G; Zuberi Z; Norman M; Kaba R; Grimster A; Gallagher MM
    Europace; 2017 Aug; 19(8):1317-1321. PubMed ID: 27702870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy and safety comparison between different types of novel design enhanced open-irrigated ablation catheters in creating cavo-tricuspid isthmus block.
    Hamaya R; Miyazaki S; Kajiyama T; Watanabe T; Kusa S; Nakamura H; Hachiya H; Iesaka Y
    J Cardiol; 2018 May; 71(5):513-516. PubMed ID: 29239758
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.
    Maurer T; Rottner L; Makimoto H; Reissmann B; Heeger CH; Lemes C; Fink T; Riedl J; Santoro F; Wohlmuth P; Volkmer M; Mathew S; Metzner A; Ouyang F; Kuck KH; Sohns C
    Clin Res Cardiol; 2018 Nov; 107(11):1003-1012. PubMed ID: 29740700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Porous tip contact force-sensing catheters for pulmonary vein isolation: performance in a clinical routine setting.
    Plenge T; van den Bruck JH; Lüker J; Sultan A; Steven D
    J Interv Card Electrophysiol; 2020 Mar; 57(2):251-259. PubMed ID: 31321659
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ablation Index and Surround Flow Catheter Irrigation: Impedance-Based Appraisal in Clinical Ablation.
    Ullah W; Hunter RJ; Finlay MC; McLean A; Dhinoja MB; Sporton S; Earley MJ; Schilling RJ
    JACC Clin Electrophysiol; 2017 Oct; 3(10):1080-1088. PubMed ID: 29759489
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.
    Reichlin T; Knecht S; Lane C; Kühne M; Nof E; Chopra N; Tadros TM; Reddy VY; Schaer B; John RM; Osswald S; Stevenson WG; Sticherling C; Michaud GF
    Heart Rhythm; 2014 Feb; 11(2):194-201. PubMed ID: 24177370
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial.
    Chinitz LA; Melby DP; Marchlinski FE; Delaughter C; Fishel RS; Monir G; Patel AM; Gibson DN; Athill CA; Ming Boo L; Stagg R; Natale A
    Europace; 2018 Nov; 20(FI_3):f392-f400. PubMed ID: 29016769
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-world outcomes comparison among adults with atrial fibrillation undergoing catheter ablation with a contact force porous tip catheter versus a second-generation cryoballoon catheter: a retrospective analysis of multihospital US database.
    Costea A; Goldstein L; Maccioni S; Kalsekar I; Khanna R
    BMJ Open; 2020 Aug; 10(8):e035499. PubMed ID: 32759243
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the lesion formation and safety in ex vivo porcine heart study: Using ThermoCool SmartTouch and ThermoCool SmartTouch-SF catheters.
    Guo M; Qu L; Zhang N; Yan R; Xue Z; Sun M; Wang R
    J Cardiovasc Electrophysiol; 2021 Aug; 32(8):2077-2089. PubMed ID: 33928716
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term safety and effectiveness of paroxysmal atrial fibrillation ablation using a porous tip contact force-sensing catheter from the SMART SF trial.
    Natale A; Monir G; Patel AM; Fishel RS; Marchlinski FE; Delaughter MC; Athill CA; Melby DP; Gonzalez MD; Hariharan R; Gidney B; Tan T; Chinitz LA
    J Interv Card Electrophysiol; 2021 Jun; 61(1):63-69. PubMed ID: 32462550
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparisons of procedural characteristics and clinical outcomes between SMARTTOUCH SURROUNDFLOW catheter and other catheters for atrial fibrillation radiofrequency catheter ablation: a systematic literature review.
    Li J; Zhou G; Li X; Huang S; Lin H; Lin S; Tan L; Chen W; Huang X; Wang Y
    BMJ Open; 2023 Oct; 13(10):e075579. PubMed ID: 37848300
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced efficiency of a novel porous tip irrigated RF ablation catheter for pulmonary vein isolation.
    Park CI; Lehrmann H; Keyl C; Weber R; Schurr P; Schiebeling-Römer J; Allgeier J; Herrera CS; Kienzle RP; Shah D; Neumann FJ; Arentz T; Jadidi AS
    J Cardiovasc Electrophysiol; 2013 Dec; 24(12):1328-35. PubMed ID: 23889915
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of a contact force-sensing ablation catheter with advanced catheter location significantly reduces fluoroscopy time and radiation dose in catheter ablation of atrial fibrillation.
    Lee G; Hunter RJ; Lovell MJ; Finlay M; Ullah W; Baker V; Dhinoja MB; Sporton S; Earley MJ; Schilling RJ
    Europace; 2016 Feb; 18(2):211-8. PubMed ID: 26318548
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of the new contact force sensing ablation catheter dramatically reduces fluoroscopy time during atrial fibrillation ablation procedures.
    Naniwadekar A; Joshi K; Greenspan A; Mainigi S
    Indian Pacing Electrophysiol J; 2016; 16(3):83-87. PubMed ID: 27788997
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis.
    Macle L; Frame D; Gache LM; Monir G; Pollak SJ; Boo LM
    BMJ Open; 2019 Jun; 9(6):e023775. PubMed ID: 31189669
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results.
    Marijon E; Fazaa S; Narayanan K; Guy-Moyat B; Bouzeman A; Providencia R; Treguer F; Combes N; Bortone A; Boveda S; Combes S; Albenque JP
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):130-7. PubMed ID: 24433324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.
    Natale A; Reddy VY; Monir G; Wilber DJ; Lindsay BD; McElderry HT; Kantipudi C; Mansour MC; Melby DP; Packer DL; Nakagawa H; Zhang B; Stagg RB; Boo LM; Marchlinski FE
    J Am Coll Cardiol; 2014 Aug; 64(7):647-56. PubMed ID: 25125294
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters.
    Winterfield JR; Jensen J; Gilbert T; Marchlinski F; Natale A; Packer D; Reddy V; Mahapatra S; Wilber DJ
    J Cardiovasc Electrophysiol; 2016 Jan; 27(1):102-9. PubMed ID: 26359632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.