1. Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate
Linares Rosales HM; Archambault L; Beddar S; Beaulieu L
Med Phys; 2020 Sep; 47(9):4477-4490. PubMed ID: 32443175
[TBL] [Abstract][Full Text] [Related]
2. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
[TBL] [Abstract][Full Text] [Related]
3. On the use of machine learning methods for mPSD calibration in HDR brachytherapy.
Linares Rosales HM; Couture G; Archambault L; Beddar S; Després P; Beaulieu L
Phys Med; 2021 Nov; 91():73-79. PubMed ID: 34717139
[TBL] [Abstract][Full Text] [Related]
4. A scintillation dosimeter with real-time positional tracking information for in vivo dosimetry error detection in HDR brachytherapy.
Tho D; Lavallée MC; Beaulieu L
J Appl Clin Med Phys; 2023 Dec; 24(12):e14150. PubMed ID: 37731203
[TBL] [Abstract][Full Text] [Related]
5. 3D source tracking and error detection in HDR using two independent scintillator dosimetry systems.
Linares Rosales HM; Johansen JG; Kertzscher G; Tanderup K; Beaulieu L; Beddar S
Med Phys; 2021 May; 48(5):2095-2107. PubMed ID: 33222208
[TBL] [Abstract][Full Text] [Related]
6. Six-probe scintillator dosimeter for treatment verification in HDR-brachytherapy.
Gonod M; Suarez MA; Avila CC; Karakhanyan V; Eustache C; Laskri S; Crouzilles J; Vinchant JF; Aubignac L; Grosjean T
Med Phys; 2023 Nov; 50(11):7192-7202. PubMed ID: 37738612
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo dosimetric characterization of a new high dose rate
Famulari G; Linares Rosales HM; Dupere J; Medich DC; Beaulieu L; Enger SA
Med Phys; 2020 Sep; 47(9):4563-4573. PubMed ID: 32686145
[TBL] [Abstract][Full Text] [Related]
8. High resolution small-scale inorganic scintillator detector: HDR brachytherapy application.
Debnath SBC; Ferre M; Tonneau D; Fauquet C; Tallet A; Goncalves A; Darreon J
Med Phys; 2021 Apr; 48(4):1485-1496. PubMed ID: 33476399
[TBL] [Abstract][Full Text] [Related]
9. A high-Z inorganic scintillator-based detector for time-resolved in vivo dosimetry during brachytherapy.
Jørgensen EB; Johansen JG; Overgaard J; Piché-Meunier D; Tho D; Rosales HML; Tanderup K; Beaulieu L; Kertzscher G; Beddar S
Med Phys; 2021 Nov; 48(11):7382-7398. PubMed ID: 34586641
[TBL] [Abstract][Full Text] [Related]
10. Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.
Tho D; Beaulieu L
Med Phys; 2019 May; 46(5):2031-2036. PubMed ID: 30919450
[TBL] [Abstract][Full Text] [Related]
11. Positional and angular tracking of HDR
Aldelaijan S; Devic S; Bekerat H; Papaconstadopoulos P; Schneider J; Seuntjens J; Cormack RA; Buzurovic IM
Med Phys; 2020 Dec; 47(12):6122-6139. PubMed ID: 33064876
[TBL] [Abstract][Full Text] [Related]
12. On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy.
Therriault-Proulx F; Beddar S; Beaulieu L
Med Phys; 2013 Jun; 40(6):062101. PubMed ID: 23718599
[TBL] [Abstract][Full Text] [Related]
13. In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: feasibility study.
Reniers B; Landry G; Eichner R; Hallil A; Verhaegen F
Med Phys; 2012 Apr; 39(4):1925-35. PubMed ID: 22482614
[TBL] [Abstract][Full Text] [Related]
14. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
[TBL] [Abstract][Full Text] [Related]
15. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
[TBL] [Abstract][Full Text] [Related]
16. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.
Geso M; Robinson N; Schumer W; Williams K
Australas Phys Eng Sci Med; 2004 Mar; 27(1):5-10. PubMed ID: 15156701
[TBL] [Abstract][Full Text] [Related]
17. Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.
Eichmann M; Thomann B
Med Phys; 2017 Sep; 44(9):4900-4909. PubMed ID: 28548280
[TBL] [Abstract][Full Text] [Related]
18. In vivo dosimeters for HDR brachytherapy: a comparison of a diamond detector, MOSFET, TLD, and scintillation detector.
Lambert J; Nakano T; Law S; Elsey J; McKenzie DR; Suchowerska N
Med Phys; 2007 May; 34(5):1759-65. PubMed ID: 17555257
[TBL] [Abstract][Full Text] [Related]
19. Suitability of the microDiamond detector for experimental determination of the anisotropy function of High Dose Rate
Rossi G; Gainey M; Kollefrath M; Hofmann E; Baltas D
Med Phys; 2020 Nov; 47(11):5838-5851. PubMed ID: 32970875
[TBL] [Abstract][Full Text] [Related]
20. Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.
Therriault-Proulx F; Beddar S; Briere TM; Archambault L; Beaulieu L
Med Phys; 2011 Apr; 38(4):2176-9. PubMed ID: 21626951
[TBL] [Abstract][Full Text] [Related]