175 related articles for article (PubMed ID: 32450498)
1. Studies of combined NO-eluting/CD47-modified polyurethane surfaces for synergistic enhancement of biocompatibility.
Zhang Q; Stachelek SJ; Inamdar VV; Alferiev I; Nagaswami C; Weisel JW; Hwang JH; Meyerhoff ME
Colloids Surf B Biointerfaces; 2020 Apr; 192():111060. PubMed ID: 32450498
[TBL] [Abstract][Full Text] [Related]
2. Enhanced biocompatibility of CD47-functionalized vascular stents.
Slee JB; Alferiev IS; Nagaswami C; Weisel JW; Levy RJ; Fishbein I; Stachelek SJ
Biomaterials; 2016 May; 87():82-92. PubMed ID: 26914699
[TBL] [Abstract][Full Text] [Related]
3. The effect of CD47 modified polymer surfaces on inflammatory cell attachment and activation.
Stachelek SJ; Finley MJ; Alferiev IS; Wang F; Tsai RK; Eckells EC; Tomczyk N; Connolly JM; Discher DE; Eckmann DM; Levy RJ
Biomaterials; 2011 Jul; 32(19):4317-26. PubMed ID: 21429575
[TBL] [Abstract][Full Text] [Related]
4. Stability and bioactivity of pepCD47 attachment on stainless steel surfaces.
Inamdar VV; Fitzpatrick E; Alferiev I; Nagaswami C; Spruce LA; Fazelinia H; Bratinov G; Seeholzer SH; Levy RJ; Fishbein I; Stachelek SJ
Acta Biomater; 2020 Mar; 104():231-240. PubMed ID: 31935523
[TBL] [Abstract][Full Text] [Related]
5. Inhibition of bacterial adhesion and biofilm formation by dual functional textured and nitric oxide releasing surfaces.
Xu LC; Wo Y; Meyerhoff ME; Siedlecki CA
Acta Biomater; 2017 Mar; 51():53-65. PubMed ID: 28087484
[TBL] [Abstract][Full Text] [Related]
6. Diminished adhesion and activation of platelets and neutrophils with CD47 functionalized blood contacting surfaces.
Finley MJ; Rauova L; Alferiev IS; Weisel JW; Levy RJ; Stachelek SJ
Biomaterials; 2012 Aug; 33(24):5803-11. PubMed ID: 22613135
[TBL] [Abstract][Full Text] [Related]
7. Mitigation of Blood Borne Cell Attachment to Metal Implants through CD47-Derived Peptide Immobilization.
Inamdar VV; Fitzpatrick EG; Alferiev IS; Levy RJ; Stachelek SJ; Fishbein I
J Vis Exp; 2020 Dec; (166):. PubMed ID: 33346187
[TBL] [Abstract][Full Text] [Related]
8. The use of the ex vivo Chandler Loop Apparatus to assess the biocompatibility of modified polymeric blood conduits.
Slee JB; Alferiev IS; Levy RJ; Stachelek SJ
J Vis Exp; 2014 Aug; (90):. PubMed ID: 25178087
[TBL] [Abstract][Full Text] [Related]
9. Improved hemocompatibility of silicone rubber extracorporeal tubing via solvent swelling-impregnation of S-nitroso-N-acetylpenicillamine (SNAP) and evaluation in rabbit thrombogenicity model.
Brisbois EJ; Major TC; Goudie MJ; Bartlett RH; Meyerhoff ME; Handa H
Acta Biomater; 2016 Jun; 37():111-9. PubMed ID: 27095484
[TBL] [Abstract][Full Text] [Related]
10. Blood coagulation response and bacterial adhesion to biomimetic polyurethane biomaterials prepared with surface texturing and nitric oxide release.
Xu LC; Meyerhoff ME; Siedlecki CA
Acta Biomater; 2019 Jan; 84():77-87. PubMed ID: 30471478
[TBL] [Abstract][Full Text] [Related]
11. Enhancing analytical accuracy of intravascular electrochemical oxygen sensors via nitric oxide release using S-nitroso-N-acetyl-penicillamine (SNAP) impregnated catheter tubing.
McCabe MM; Hala P; Rojas-Pena A; Lautner-Csorba O; Major TC; Ren H; Bartlett RH; Brisbois EJ; Meyerhoff ME
Talanta; 2019 Dec; 205():120077. PubMed ID: 31450395
[TBL] [Abstract][Full Text] [Related]
12. CD47-dependent molecular mechanisms of blood outgrowth endothelial cell attachment on cholesterol-modified polyurethane.
Ueda M; Alferiev IS; Simons SB; Hebbel RP; Levy RJ; Stachelek SJ
Biomaterials; 2010 Sep; 31(25):6394-9. PubMed ID: 20538335
[TBL] [Abstract][Full Text] [Related]
13. Nitric oxide-releasing hydrophobic polymers: preparation, characterization, and potential biomedical applications.
Reynolds MM; Frost MC; Meyerhoff ME
Free Radic Biol Med; 2004 Oct; 37(7):926-36. PubMed ID: 15336308
[TBL] [Abstract][Full Text] [Related]
14. Origin of Long-Term Storage Stability and Nitric Oxide Release Behavior of CarboSil Polymer Doped with S-Nitroso-N-acetyl-D-penicillamine.
Wo Y; Li Z; Brisbois EJ; Colletta A; Wu J; Major TC; Xi C; Bartlett RH; Matzger AJ; Meyerhoff ME
ACS Appl Mater Interfaces; 2015 Oct; 7(40):22218-27. PubMed ID: 26393943
[TBL] [Abstract][Full Text] [Related]
15. Nitric oxide releasing Tygon materials: studies in donor leaching and localized nitric oxide release at a polymer-buffer interface.
Joslin JM; Lantvit SM; Reynolds MM
ACS Appl Mater Interfaces; 2013 Oct; 5(19):9285-94. PubMed ID: 23957655
[TBL] [Abstract][Full Text] [Related]
16. Polymers incorporating nitric oxide releasing/generating substances for improved biocompatibility of blood-contacting medical devices.
Frost MC; Reynolds MM; Meyerhoff ME
Biomaterials; 2005 May; 26(14):1685-93. PubMed ID: 15576142
[TBL] [Abstract][Full Text] [Related]
17. 3D Printing of Antibacterial Polymer Devices Based on Nitric Oxide Release from Embedded
Li W; Yang Y; Ehrhardt CJ; Lewinski N; Gascoyne D; Lucas G; Zhao H; Wang X
ACS Appl Bio Mater; 2021 Oct; 4(10):7653-7662. PubMed ID: 35006705
[TBL] [Abstract][Full Text] [Related]
18. Nitric oxide-releasing/generating polymers for the development of implantable chemical sensors with enhanced biocompatibility.
Wu Y; Meyerhoff ME
Talanta; 2008 May; 75(3):642-50. PubMed ID: 18585126
[TBL] [Abstract][Full Text] [Related]
19. Improving the thromboresistivity of chemical sensors via nitric oxide release: fabrication and in vivo evaluation of NO-releasing oxygen-sensing catheters.
Schoenfisch MH; Mowery KA; Rader MV; Baliga N; Wahr JA; Meyerhoff ME
Anal Chem; 2000 Mar; 72(6):1119-26. PubMed ID: 10740848
[TBL] [Abstract][Full Text] [Related]
20. Improved Polymer Hemocompatibility for Blood-Contacting Applications via
Griffin L; Douglass M; Goudie M; Hopkins SP; Schmiedt C; Handa H
ACS Appl Mater Interfaces; 2022 Mar; 14(9):11116-11123. PubMed ID: 35225600
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]