168 related articles for article (PubMed ID: 32451400)
1. A Portable Smartphone-linked Device for Direct, Rapid and Chemical-Free Hemoglobin Assay.
Lee J; Song J; Choi JH; Kim S; Kim U; Nguyen VT; Lee JS; Joo C
Sci Rep; 2020 May; 10(1):8606. PubMed ID: 32451400
[TBL] [Abstract][Full Text] [Related]
2. Hemoglobin assay in anemic patients with a photothermal spectral-domain optical coherence reflectometric sensor.
Kim H; Song S; Yim J; Kim HO; Joo C
Clin Chim Acta; 2015 Jan; 439():71-6. PubMed ID: 25312865
[TBL] [Abstract][Full Text] [Related]
3. Non-invasive hemoglobin measurement devices require refinement to match diagnostic performance with their high level of usability and acceptability.
Young MF; Raines K; Jameel F; Sidi M; Oliveira-Streiff S; Nwajei P; McGlamry K; Ou J; Oladele A; Suchdev PS
PLoS One; 2021; 16(7):e0254629. PubMed ID: 34270591
[TBL] [Abstract][Full Text] [Related]
4. A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering.
Kim U; Song J; Ryu S; Kim S; Joo C
J Vis Exp; 2016 Dec; (118):. PubMed ID: 28060269
[TBL] [Abstract][Full Text] [Related]
5. Validity and correspondence of non-invasively determined hemoglobin concentrations by two trans-cutaneous digital measuring devices.
Crowley C; Montenegro-Bethancourt G; Solomons NW; Schűmann K
Asia Pac J Clin Nutr; 2012; 21(2):191-200. PubMed ID: 22507604
[TBL] [Abstract][Full Text] [Related]
6. Agreement between dried blood spots and HemoCue in Tamil Nadu, India.
Roshania RP; Mehta RV; Shete A; Bingewar R; Kulkarni S; Mahajan A; Miller G; Tarozzi A; Martorell R
Sci Rep; 2021 Apr; 11(1):9285. PubMed ID: 33927229
[TBL] [Abstract][Full Text] [Related]
7. Blood draw site and analytic device influence hemoglobin measurements.
Killilea DW; Kuypers FA; Larkin SK; Schultz K
PLoS One; 2022; 17(11):e0278350. PubMed ID: 36449486
[TBL] [Abstract][Full Text] [Related]
8. Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening.
Kim MJ; Park Q; Kim MH; Shin JW; Kim HO
Ann Lab Med; 2013 Jul; 33(4):261-7. PubMed ID: 23826562
[TBL] [Abstract][Full Text] [Related]
9. Automated Measurement of Plasma Cell-Free Hemoglobin Using the Hemolysis Index Check Function.
Barbhuiya MA; Pederson EC; Straub ML; Neibauer TL; Salter WF; Saylor EL; Scott SC; Zhu Y
J Appl Lab Med; 2020 Mar; 5(2):281-289. PubMed ID: 32445381
[TBL] [Abstract][Full Text] [Related]
10. Comparability of Point-of-Care versus Central Laboratory Hemoglobin Determination in Emergency Patients at a Supra-Maximal Care Hospital.
Dolscheid-Pommerich RC; Dolscheid S; Grigutsch D; Stoffel-Wagner B; Graeff I
PLoS One; 2016; 11(11):e0166521. PubMed ID: 27880783
[TBL] [Abstract][Full Text] [Related]
11. Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan.
Adam I; Ahmed S; Mahmoud MH; Yassin MI
Diagn Pathol; 2012 Mar; 7():30. PubMed ID: 22436620
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of point-of-care testing device for anemia detection: A cross-sectional method comparison study from Thailand.
Chantkran W; Jamnarnwej P; Sritanabutr P; Arnutti P
J Clin Lab Anal; 2021 Oct; 35(10):e23976. PubMed ID: 34427961
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Hemoglobin Measurements by 3 Point-of-Care Devices With Standard Laboratory Values and Reliability Regarding Decisions for Blood Transfusion.
Johnson M; Marwick PC; Coetzee JF
Anesth Analg; 2020 Aug; 131(2):640-649. PubMed ID: 31764158
[TBL] [Abstract][Full Text] [Related]
14. Comparison between the HemoCue and an automated counter for measuring hemoglobin.
Paiva Ade A; Rondó PH; Silva SS; Latorre Mdo R
Rev Saude Publica; 2004 Aug; 38(4):585-7. PubMed ID: 15311302
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of HemoCue301 portable hemoglobin analyzer for anemia screening in capillary blood from women of reproductive age in a deprived region of Northern Peru: An on-field study.
Alarcón-Yaquetto DE; Rueda-Torres L; Bailon N; Barreto PV; Málaga G
PLoS One; 2023; 18(11):e0293984. PubMed ID: 37963155
[TBL] [Abstract][Full Text] [Related]
16. Interference of bovine hemoglobin-based oxygen carrier-201 (Hemopure) on four hematology analyzers.
Bronkhorst-van der Helm MW; Weerkamp F; Huisman A; Huisman EJ; Russcher H
Int J Lab Hematol; 2023 Dec; 45(6):869-874. PubMed ID: 37571820
[TBL] [Abstract][Full Text] [Related]
17. Smartphone dongle for simultaneous measurement of hemoglobin concentration and detection of HIV antibodies.
Guo T; Patnaik R; Kuhlmann K; Rai AJ; Sia SK
Lab Chip; 2015 Sep; 15(17):3514-20. PubMed ID: 26190320
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of 24-second cyanide-containing and cyanide-free methods for whole blood hemoglobin on the Technicon H*1TM analyzer with normal and abnormal blood samples.
Malin MJ; Sclafani LD; Wyatt JL
Am J Clin Pathol; 1989 Sep; 92(3):286-94. PubMed ID: 2773849
[TBL] [Abstract][Full Text] [Related]
19. A portable smartphone-based hemoglobin point-of-care testing platform for accurate anemia diagnostics.
Fu Q; Qi T; Wu Z; He Y; Guan S; Luo S; Zhang Q; Luo W; Xiao W; Situ B; Zheng L
Biosens Bioelectron; 2022 Dec; 217():114711. PubMed ID: 36113300
[TBL] [Abstract][Full Text] [Related]
20. Short communication: evaluation of an automated in-house hematology analyzer for bovine blood.
Roland L; Drillich M; Fidlschuster B; Schwendenwein I; Iwersen M
J Dairy Sci; 2014 Sep; 97(9):5580-6. PubMed ID: 24997670
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]