These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

826 related articles for article (PubMed ID: 32451876)

  • 1. Left ventricular global longitudinal strain in bicupsid aortic valve patients: head-to-head comparison between computed tomography, 4D flow cardiovascular magnetic resonance and speckle-tracking echocardiography.
    van den Hoven AT; Yilmazer S; Chelu RG; van Grootel RWJ; Minderhoud SCS; Bons LR; van Berendoncks AM; Duijnhouwer AL; Siebelink HJ; van den Bosch AE; Budde RPJ; Roos-Hesselink JW; Hirsch A
    Int J Cardiovasc Imaging; 2020 Sep; 36(9):1771-1780. PubMed ID: 32451876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT-derived left ventricular global strain: a head-to-head comparison with speckle tracking echocardiography.
    Ammon F; Bittner D; Hell M; Mansour H; Achenbach S; Arnold M; Marwan M
    Int J Cardiovasc Imaging; 2019 Sep; 35(9):1701-1707. PubMed ID: 30953252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of aortic valve 4D flow analysis and myocardial deformation by cardiovascular magnetic resonance in patients after the arterial switch operation.
    van Wijk WHS; Breur JMPJ; Westenberg JJM; Driessen MMP; Meijboom FJ; Driesen B; de Baat EC; Doevendans PAFM; Leiner T; Grotenhuis HB
    J Cardiovasc Magn Reson; 2019 Mar; 21(1):20. PubMed ID: 30879465
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Global longitudinal strain assessment by computed tomography in severe aortic stenosis patients - Feasibility using feature tracking analysis.
    Fukui M; Xu J; Abdelkarim I; Sharbaugh MS; Thoma FW; Althouse AD; Pedrizzetti G; Cavalcante JL
    J Cardiovasc Comput Tomogr; 2019; 13(2):157-162. PubMed ID: 30396864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Global longitudinal strain and global circumferential strain by speckle-tracking echocardiography and feature-tracking cardiac magnetic resonance imaging: comparison with left ventricular ejection fraction.
    Onishi T; Saha SK; Delgado-Montero A; Ludwig DR; Onishi T; Schelbert EB; Schwartzman D; Gorcsan J
    J Am Soc Echocardiogr; 2015 May; 28(5):587-96. PubMed ID: 25577185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease.
    Bak SH; Ko SM; Jeon HJ; Yang HS; Hwang HK; Song MG
    Acta Radiol; 2012 Apr; 53(3):270-7. PubMed ID: 22319133
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease.
    van den Hoven AT; Mc-Ghie JS; Chelu RG; Duijnhouwer AL; Baggen VJM; Coenen A; Vletter WB; Dijkshoorn ML; van den Bosch AE; Roos-Hesselink JW
    Int J Cardiovasc Imaging; 2017 Dec; 33(12):1895-1903. PubMed ID: 28631106
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contrast-enhanced echocardiographic measurement of longitudinal strain: accuracy and its relationship with image quality.
    Karagodin I; Genovese D; Kruse E; Patel AR; Rashedi N; Lang RM; Mor-Avi V
    Int J Cardiovasc Imaging; 2020 Mar; 36(3):431-439. PubMed ID: 31720940
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Left ventricular mechanics assessed by two-dimensional echocardiography and cardiac magnetic resonance imaging: comparison of high-resolution speckle tracking and feature tracking.
    Aurich M; Keller M; Greiner S; Steen H; Aus dem Siepen F; Riffel J; Katus HA; Buss SJ; Mereles D
    Eur Heart J Cardiovasc Imaging; 2016 Dec; 17(12):1370-1378. PubMed ID: 27013249
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of CT-derived myocardial strain measurement in patients with advanced cardiac valve disease.
    Vach M; Vogelhuber J; Weber M; Sprinkart AM; Pieper CC; Block W; Kuetting D; Attenberger UI; Luetkens JA
    Sci Rep; 2021 Apr; 11(1):8793. PubMed ID: 33888835
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement.
    Erley J; Genovese D; Tapaskar N; Alvi N; Rashedi N; Besser SA; Kawaji K; Goyal N; Kelle S; Lang RM; Mor-Avi V; Patel AR
    J Cardiovasc Magn Reson; 2019 Aug; 21(1):46. PubMed ID: 31391036
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aortic regurgitation assessment by cardiovascular magnetic resonance imaging and transthoracic echocardiography: intermodality disagreement impacting on prediction of post-surgical left ventricular remodeling.
    Neisius U; Tsao CW; Hauser TH; Patel AD; Pierce P; Ben-Assa E; Nezafat R; Manning WJ
    Int J Cardiovasc Imaging; 2020 Jan; 36(1):91-100. PubMed ID: 31414256
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: Comparison with 3 Tesla cardiac magnetic resonance.
    Levy F; Dan Schouver E; Iacuzio L; Civaia F; Rusek S; Dommerc C; Marechaux S; Dor V; Tribouilloy C; Dreyfus G
    Arch Cardiovasc Dis; 2017 Nov; 110(11):580-589. PubMed ID: 28566200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Right ventricular global longitudinal strain is an independent predictor of right ventricular function: a multimodality study of cardiac magnetic resonance imaging, real time three-dimensional echocardiography and speckle tracking echocardiography.
    Lu KJ; Chen JX; Profitis K; Kearney LG; DeSilva D; Smith G; Ord M; Harberts S; Calafiore P; Jones E; Srivastava PM
    Echocardiography; 2015 Jun; 32(6):966-74. PubMed ID: 25287078
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aortic Measurements in Patients with Aortopathy are Larger and More Reproducible by Cardiac Magnetic Resonance Compared with Echocardiography.
    Nejatian A; Yu J; Geva T; White MT; Prakash A
    Pediatr Cardiol; 2015 Dec; 36(8):1761-73. PubMed ID: 26174757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reproducibility of 4D cardiac computed tomography feature tracking myocardial strain and comparison against speckle-tracking echocardiography in patients with severe aortic stenosis.
    Bernhard B; Grogg H; Zurkirchen J; Demirel C; Hagemeyer D; Okuno T; Brugger N; De Marchi S; Huber AT; Berto MB; Spano G; Stortecky S; Windecker S; Pilgrim T; Gräni C
    J Cardiovasc Comput Tomogr; 2022; 16(4):309-318. PubMed ID: 35148996
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of aortic valve stenosis using cardiovascular magnetic resonance: comparison of an original semiautomated analysis of phase-contrast cardiovascular magnetic resonance with Doppler echocardiography.
    Defrance C; Bollache E; Kachenoura N; Perdrix L; Hrynchyshyn N; Bruguière E; Redheuil A; Diebold B; Mousseaux E
    Circ Cardiovasc Imaging; 2012 Sep; 5(5):604-12. PubMed ID: 22798520
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison between cardiovascular magnetic resonance and transthoracic Doppler echocardiography for the estimation of effective orifice area in aortic stenosis.
    Garcia J; Kadem L; Larose E; Clavel MA; Pibarot P
    J Cardiovasc Magn Reson; 2011 Apr; 13(1):25. PubMed ID: 21527021
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multimodality imaging in bicuspid aortic valve.
    Galian-Gay L; Rodríguez-Palomares J; Guala A; Michelena HI; Evangelista A
    Prog Cardiovasc Dis; 2020; 63(4):442-451. PubMed ID: 32531300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Value of three-dimensional speckle-tracking in detecting left ventricular dysfunction in patients with aortic valvular diseases.
    Li CM; Li C; Bai WJ; Zhang XL; Tang H; Qing Z; Li R
    J Am Soc Echocardiogr; 2013 Nov; 26(11):1245-52. PubMed ID: 23993696
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 42.