These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

256 related articles for article (PubMed ID: 32454886)

  • 21. Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage.
    Lavon K; Marom G; Bianchi M; Halevi R; Hamdan A; Morany A; Raanani E; Bluestein D; Haj-Ali R
    Med Biol Eng Comput; 2019 Oct; 57(10):2129-2143. PubMed ID: 31372826
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis.
    Gonska B; Seeger J; Junker A; Rodewald C; Trepte U; Scharnbeck D; Rottbauer W; Wöhrle J
    Arch Cardiovasc Dis; 2018; 111(8-9):470-479. PubMed ID: 29128473
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transcatheter Self-Expandable Valve Implantation for Aortic Stenosis in Small Aortic Annuli: The TAVI-SMALL Registry.
    Regazzoli D; Chiarito M; Cannata F; Pagnesi M; Miura M; Ziviello F; Picci A; Reifart J; De Marco F; Bedogni F; Adamo M; Curello S; Teles R; Taramasso M; Barbanti M; Tamburino C; Stefanini GG; Mangieri A; Giannini F; Pagnotta PA; Maisano F; Kim WK; Van Mieghem NM; Colombo A; Reimers B; Latib A;
    JACC Cardiovasc Interv; 2020 Jan; 13(2):196-206. PubMed ID: 31883714
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation.
    Chodór P; Wilczek K; Przybylski R; Głowacki J; Kukulski T; Streb W; Niklewski T; Honisz G; Trzeciak P; Podolecki T; Włoch Ł; Zembala M; Kalarus Z
    Cardiol J; 2017; 24(5):467-476. PubMed ID: 28150295
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Role of computed tomography in transcatheter aortic valve implantation and valve-in-valve implantation: complete review of preprocedural and postprocedural imaging.
    Chiocchi M; Ricci F; Pasqualetto M; D'Errico F; Benelli L; Pugliese L; Cavallo AU; Forcina M; Presicce M; De Stasio V; Di Donna C; Di Tosto F; Spiritigliozzi L; Floris R; Romeo F
    J Cardiovasc Med (Hagerstown); 2020 Mar; 21(3):182-191. PubMed ID: 32012138
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function.
    Hahn RT; Leipsic J; Douglas PS; Jaber WA; Weissman NJ; Pibarot P; Blanke P; Oh JK
    JACC Cardiovasc Imaging; 2019 Jan; 12(1):25-34. PubMed ID: 29909110
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation.
    Rocatello G; El Faquir N; de Backer O; Swaans MJ; Latib A; Vicentini L; Segers P; De Beule M; de Jaegere P; Mortier P
    J Cardiovasc Transl Res; 2019 Oct; 12(5):435-446. PubMed ID: 31444672
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Application of transcatheter valves for aortic valve replacement in pediatric patients: A case series.
    Sinha S; Khan A; Qureshi AM; Suh W; Laks H; Aboulhosn J; Biniwale R; Adachi I; Fernando A; Levi D
    Catheter Cardiovasc Interv; 2020 Feb; 95(2):253-261. PubMed ID: 31609055
    [TBL] [Abstract][Full Text] [Related]  

  • 29. SAVR versus TAVI: What about the Hemodynamic Performance? An In Vivo and In Vitro Analysis.
    Eghbalzadeh K; Rahmanian PB; Giese D; Kuhn EW; Djordjevic I; Kaya S; Weber C; Baldus S; Mader N; Wahlers TCW
    Thorac Cardiovasc Surg; 2020 Oct; 68(7):608-615. PubMed ID: 31505690
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Leaflet thrombosis following transcatheter aortic valve implantation.
    Marwan M; Mekkhala N; Göller M; Röther J; Bittner D; Schuhbaeck A; Hell M; Muschiol G; Kolwelter J; Feyrer R; Schlundt C; Achenbach S; Arnold M
    J Cardiovasc Comput Tomogr; 2018; 12(1):8-13. PubMed ID: 29195844
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison of the fully repositionable and retrievable Boston Lotus and direct flow medical valves for the treatment of severe aortic stenosis: A single center experience.
    Giannini F; Latib A; Montorfano M; Ruparelia N; Romano V; Longoni M; Ferri L; Jabbour R; Mangieri A; Regazzoli D; Ancona M; Buzzatti N; Azzalini L; Tanaka A; Agricola E; Chieffo A; Alfieri O; Colombo A
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):966-974. PubMed ID: 28941127
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation.
    Rocatello G; De Santis G; De Bock S; De Beule M; Segers P; Mortier P
    Cardiovasc Eng Technol; 2019 Sep; 10(3):456-468. PubMed ID: 31197702
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Hemodynamic comparison of CoreValve and SAPIEN-XT TAVI valves in Japanese patients.
    Shishido K; Yamanaka F; Ochiai T; Yamabe T; Noguchi K; Ota T; Koide Y; Ogino H; Tanaka Y; Saito S
    Heart Vessels; 2019 Oct; 34(10):1674-1683. PubMed ID: 30993441
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing.
    Subramanyam P; Legasto AC; Al'Aref SJ; Wong SC; Truong QA
    Int J Cardiovasc Imaging; 2020 Nov; 36(11):2291-2297. PubMed ID: 32621038
    [TBL] [Abstract][Full Text] [Related]  

  • 36. 3D printing of the aortic annulus based on cardiovascular computed tomography: Preliminary experience in pre-procedural planning for aortic valve sizing.
    Faletti R; Gatti M; Cosentino A; Bergamasco L; Cura Stura E; Garabello D; Pennisi G; Salizzoni S; Veglia S; Ottavio D; Rinaldi M; Fonio P
    J Cardiovasc Comput Tomogr; 2018; 12(5):391-397. PubMed ID: 29857953
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve.
    Pasta S; Cannata S; Gentile G; Di Giuseppe M; Cosentino F; Pasta F; Agnese V; Bellavia D; Raffa GM; Pilato M; Gandolfo C
    Med Biol Eng Comput; 2020 Apr; 58(4):815-829. PubMed ID: 32026185
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients: The OCEAN-TAVI Registry.
    Miyasaka M; Tada N; Taguri M; Kato S; Enta Y; Otomo T; Hata M; Watanabe Y; Naganuma T; Araki M; Yamanaka F; Shirai S; Ueno H; Mizutani K; Tabata M; Higashimori A; Takagi K; Yamamoto M; Hayashida K;
    JACC Cardiovasc Interv; 2018 Apr; 11(8):771-780. PubMed ID: 29673509
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?
    Horehledova B; Mihl C; Hendriks BMF; Eijsvoogel NG; Vainer J; Veenstra LF; Wildberger JE; Das M
    Int J Cardiovasc Imaging; 2018 Nov; 34(11):1819-1829. PubMed ID: 29909590
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Prediction of paravalvular leakage after transcatheter aortic valve implantation.
    Di Martino LF; Vletter WB; Ren B; Schultz C; Van Mieghem NM; Soliman OI; Di Biase M; de Jaegere PP; Geleijnse ML
    Int J Cardiovasc Imaging; 2015 Oct; 31(7):1461-8. PubMed ID: 26187523
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.